Impact of Heart Rhythm Status on Registration Accuracy of the Left Atrium for Catheter Ablation of Atrial Fibrillation
Abstract
Introduction: Registration accuracy is of crucial importance to the successful use of image integration technique to facilitate atrial fibrillation (AF) ablation. It is well known that a patient's heart rhythm can switch from sinus rhythm (SR) to AF or vice versa during an AF ablation procedure. However, the impact of the heart rhythm change on the accuracy of left atrium (LA) registration has not been studied. Methods: This study included 10 patients who underwent AF ablation. Prior to the ablation procedure, the patients had contrast‐enhanced cardiac CT scan obtained during SR (n = 7) or AF (n = 3). Using an image integration system (CartoMerge, Biosense Webster Inc.), LA CT surface reconstruction was registered to the real‐time mapping space represented by the LA electroanatomic map. To determine the effect of rhythm change on registration accuracy, LA registration was performed during both SR and AF in each study subject. The distance between the surface of the registered LA CT reconstruction and multiple real‐time LA electroanatomic map points (surface‐to‐point distance) was used as an index for LA registration error. The position error after rhythm change was defined as the surface‐to‐point distance between the surface of the LA CT reconstruction registered in the initial rhythm and the LA electroanatomic map points sampled during the second rhythm. Results: A total of 90 ± 12 and 92 ± 9.5 LA electroanatomic map points were sampled for registration during SR and AF, respectively. No significant difference was found in surface‐to‐point distance when comparing SR with AF as the underlying rhythm during registration (1.91 ± 0.24 vs 1.84 ± 0.38 mm, P = 0.60). The position error after rhythm change was not different from the surface‐to‐point distance of LA registration conducted during the initial rhythm (2.05 ± 0.39 vs 1.96 ± 0.29 mm, P = 0.4). The surface‐to‐point distance did not differ when comparing LA registration conducted during the same versus different rhythm from that during CT imaging (1.96 ± 0.29 vs 1.79 ± 0.32 mm, P = 0.13). Conclusions: Registration error did not differ between LA registrations conducted during the same versus different rhythm as was present during CT imaging. Rhythm changes between SR and AF did not introduce significant error to the LA registration process for catheter ablation of AF. These findings are reassuring and suggest that reregistration is not needed if a patient's rhythm changes from SR to AF or vice versa during an ablation procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kato, R., Lickfett, L., Meininger, G., Dickfeld, T., Wu, R., Juang, G., Angkeow, P., LaCorte, J., Bluemke, D., Berger, R., et al. (2003) · Circulation · doi:10.1161/01.cir.0000061951.81767.4e · Cited by 492
Self-citationDong, J., Calkins, H., Solomon, S. B., Lai, S., Dalal, D., Lardo, A., Brem, E., Preiss, A., Berger, R. D., Halperin, H., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.565200 · Cited by 233
Self-citationDONG, J., DICKFELD, T., DALAL, D., CHEEMA, A., VASAMREDDY, C. R., HENRIKSON, C. A., MARINE, J. E., HALPERIN, H. R., BERGER, R. D., LIMA, J. A. C., et al. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00425.x · Cited by 227
Self-citationKISTLER, P. M., EARLEY, M. J., HARRIS, S., ABRAMS, D., ELLIS, S., SPORTON, S. C., & SCHILLING, R. J. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00371.x · Cited by 182
Tops, L. F., Bax, J. J., Zeppenfeld, K., Jongbloed, M. R. M., Lamb, H. J., van der Wall, E. E., & Schalij, M. J. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.07.019 · Cited by 180
Computed Tomography‐Fluoroscopy Image Integration‐Guided Catheter Ablation of Atrial Fibrillation
Sra, J. S., Narayan, G. A., Krum, D. P., Malloy, A., Cooley, R., Bhatia, A., Dhala, A. A., Blanck, Z., Nangia, V., & Akhtar, M. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00734.x · Cited by 131
Martinek, M., Nesser, H., Aichinger, J., Boehm, G., & Pürerfellner, H. (2007) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-006-9067-8 · Cited by 44
Vasamreddy, C. R., Jayam, V., Lickfett, L., Nasir, K., BRADLEY, D. J., ELDADAH, Z. A., Dickfeld, T. L., Donahue, K., Halperin, H. R., Berger, R. D., et al. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03352.x · Cited by 43
Self-citation
Cited by
Computationally guided personalized targeted ablation of persistent atrial fibrillation
Boyle, P. M., Zghaib, T., Zahid, S., Ali, R. L., Deng, D., Franceschi, W. H., Hakim, J. B., Murphy, M. J., Prakosa, A., Zimmerman, S. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0437-9 · Cited by 312
Self-citationSAITO, T., WAKI, K., & BECKER, A. E. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00068.x · Cited by 310
Update on the Association of Inflammation and Atrial Fibrillation
PATEL, P., DOKAINISH, H., TSAI, P., & LAKKIS, N. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01774.x · Cited by 190
CHEN, Y., PAN, N., CHENG, C., HIGA, S., CHEN, Y., & CHEN, S. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01480.x · Cited by 49
Metadata
- Authors
- DONG, J., DALAL, D., SCHERR, D., CHEEMA, A., NAZARIAN, S., BILCHICK, K., ALMASRY, I., CHENG, A., HENRIKSON, C. A., SPRAGG, D., MARINE, J. E., BERGER, R. D., & CALKINS, H.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2007-10-25
- Volume
- 18
- Issue
- 12
- Pages
- 1269-1276
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2037008570
- Cited by
- 316
- References
- 8
- FWCI
- 8.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of Heart Rhythm Status on Registration Accuracy of the Left Atrium for Catheter Ablation of Atrial Fibrillation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2007.00956.x
- The paper
- DONG, J., DALAL, D., SCHERR, D., CHEEMA, A., NAZARIAN, S., BILCHICK, K., ALMASRY, I., CHENG, A., HENRIKSON, C. A., SPRAGG, D., MARINE, J. E., BERGER, R. D., & CALKINS, H. (2007). Impact of Heart Rhythm Status on Registration Accuracy of the Left Atrium for Catheter Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2007.00956.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.