Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 272

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

The Impact of CT Image Integration into an Electroanatomic Mapping System on Clinical Outcomes of Catheter Ablation of Atrial Fibrillation

KISTLER, PETER M., RAJAPPAN, KIM, JAHNGIR, MOHAMMED, EARLEY, MARK J., HARRIS, STUART, ABRAMS, DOMINIC, GUPTA, DHIRAJ, LIEW, REGINALD, ELLIS, STEPHEN, SPORTON, SIMON C., SCHILLING, RICHARD J.·2006·Journal of Cardiovascular Electrophysiology

Abstract

Background: A detailed appreciation of left atrial/pulmonary vein (LA/PV) anatomy may be important in improving the safety and success of catheter ablation (CA) for atrial fibrillation (AF). Objectives: The aim of this nonrandomized study was to determine the impact of computerized tomography (CT) image integration into a 3‐dimensional (3D) mapping system on the clinical outcome of patients undergoing CA for AF. Methods: Ninety‐four patients (age: 56 ± 10 years) with AF (paroxysmal 46, persistent 48) underwent wide encirclement of ipsilateral PV pairs using irrigated radiofrequency ablation with the endpoint of electrical isolation. Ablation was guided by 3D mapping alone (electroanatomic 24, noncontact 23) in 47 (3DM group) patients and by CT image integration (Cartomerge®) in 47 (CT group). In persistent AF, a combination of linear ablation and targeted ablation of complex fractionated electrograms was also performed. Results: Successful PV electrical isolation did not differ between the two groups. A significant reduction in fluoroscopy times was demonstrated in the CT group (49 ± 27 minutes vs 3DM group 62 ± 26 minutes, P = 0.03). Arrhythmia recurrence was reduced in the CT group (32% vs 51% in the 3DM group, P < 0.01). In 30 symptomatic patients (12 CT and 18 3DM), repeat procedures for AF (13 in 3DM and 5 CT, P ≤ 0.10) and AT (5 in 3DM and 7 CT, P = NS) were performed. Overall success on 7‐day monitor off antiarrhythmic drugs was achieved in 60% in the 3DM group when compared with 83% in the CT group (P < 0.05) at a follow‐up of 25 ± 5 weeks. Conclusion: CA for AF guided by CT integration was associated with reduced fluoroscopy times, arrhythmia recurrence, and increased restoration of sinus rhythm. Improved visualization of complex LA geometries might improve the safety and success of CA for AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2006.00594.x

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 272

Metadata

Authors
KISTLER, P. M., RAJAPPAN, K., JAHNGIR, M., EARLEY, M. J., HARRIS, S., ABRAMS, D., GUPTA, D., LIEW, R., ELLIS, S., SPORTON, S. C., & SCHILLING, R. J.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2006-08-22
Volume
17
Issue
10
Pages
1093-1101
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2034156327
Cited by
272
References
29
FWCI
18.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Impact of CT Image Integration into an Electroanatomic Mapping System on Clinical Outcomes of Catheter Ablation of Atrial Fibrillation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2006.00594.x
The paper
KISTLER, P. M., RAJAPPAN, K., JAHNGIR, M., EARLEY, M. J., HARRIS, S., ABRAMS, D., GUPTA, D., LIEW, R., ELLIS, S., SPORTON, S. C., & SCHILLING, R. J. (2006). The Impact of CT Image Integration into an Electroanatomic Mapping System on Clinical Outcomes of Catheter Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2006.00594.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.