Persistent Inappropriate Sinus Tachycardia After Radiofrequency Ablation of Left Lateral Accessory Pathway
Open accessAbstract
A patient with palpitations and narrow QRS tachycardia was evaluated. In the EP study an atrioventricular reentrant tachycardia mediated by a left lateral accessory pathway was identified and catheter ablation was performed with success. A week later she returned with palpitations and pre‐syncope. The resting ECG showed a sinus tachycardia with 110 bpm. After unsuccessful clinical treatment with beta‐blockers, diltiazem and digoxin she underwent sinus node modification using radiofrequency catheter ablation with success. We postulated that RF application to ablate the lateral accessory pathway damaged the parasympathetic innervation in the left atrioventricular groove, causing inappropriate sinus tachycardia.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Radiofrequency catheter ablation to modify the sinus node or eliminate sympathetic inputs, at best, is partially effective.
“Radiofrequency catheter ablation to modify the sinus node or eliminate sympathetic inputs, at best, is partially effective. 10,30,60,61,76-88”
From Inappropriate sinus tachycardia (2019) · cites this paper as [60]
The Introduction reports that sinus node modification brought the patient's heart rate to 75 bpm and that she remained asymptomatic for 34 months. The Discussion suggests the ablation probably damaged sympathetic fibers. This successful case does not support the claim that such ablation is, at best, only partially effective. (LLM, conf=0.82)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Pappone, C., Santinelli, V., Manguso, F., Vicedomini, G., Gugliotta, F., Augello, G., Mazzone, P., Tortoriello, V., Landoni, G., Zangrillo, A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000112641.16340.c7 · Cited by 1,018 · see citing works
Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures
Zipes, D. P., Dimarco, J., Gillette, P. C., Jackman, W. M., Myerburg, R. J., Rahimtoola, S. H., Ritchie, J. L., Cheitlin, M. D., Garson, A., Gibbons, R. J., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80037-h · Cited by 280 · see citing works
James, T. N. (1977) · The American Journal of Cardiology · doi:10.1016/0002-9149(77)90048-0 · Cited by 190 · see citing works
Selective In Situ Parasympathetic Control of the Canine Sinoatrial and Atrioventricular Nodes
Lazzara, R., Scherlag, B. J., Robinson, M. J., & D, P. S. M. (1973) · Circulation Research · doi:10.1161/01.res.32.3.393 · Cited by 165 · see citing works
Razavi, M., Zhang, S., Yang, D., Sanders, R. A., Kar, B., Delapasse, S., Ai, T., Moreira, W., Olivier, B., Khoury, D. S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.50048.x · Cited by 154 · see citing works
Kocovic, D. Z., Harada, T., Shea, J. B., Soroff, D., & Friedman, P. L. (1993) · Circulation · doi:10.1161/01.cir.88.4.1671 · Cited by 117 · see citing works
Marron, K., Wharton, J., Sheppard, M. N., Fagan, D. T., Royston, D., Kuhn, D. M., de Leval, M. R., Whitehead, B., Anderson, R. H., & Polak, J. M. (1995) · Circulation · doi:10.1161/01.cir.92.8.2343 · Cited by 109 · see citing works
Selective parasympathectomy of automatic and conductile tissues of the canine heart
Randall, W. C., & Ardell, J. L. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h61 · Cited by 97 · see citing works
EHLERT, F. A., Goldberger, J. J., Brooks, R., Miller, S. C., & Kadish, A. H. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90872-v · Cited by 60 · see citing works
Characterization of Sinoatrial Parasympathetic Innervation in Humans
Quan, K. J., Lee, J. H., Geha, A. S., Biblo, L. A., Hare, G. F. V., Mackall, J. A., & Carlson, M. D. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00278.x · Cited by 51 · see citing works
Ren, J., Marchlinski, F. E., Callans, D. J., & Zado, E. S. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00814.x · Cited by 48 · see citing works
Functional characterization of atrial pacemaker activity
Randall, W. C., Rinkema, L. E., Jones, S. B., Moran, J. F., & Brynjolfsson, G. (1982) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1982.242.1.h98 · Cited by 27 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- Ehlert F, Goldberger J, Brooks R, Miller S, Kadish AH: Persistent in- appropriate sinus tachycardia after radiofrequency ablation of the atri- oventricular node. Am J Cardiol 1992;69:1092-1095.
- Boineau JP, Schuessler RB, Hackel DB, Miller CB, Brockus CW, Wylds AC: Widespread distribution and rate differentiation of the atrial pace- maker complex. Am J Physiol 1980;239:H406-H415.
Cited by
Sorted by citations
Inappropriate sinus tachycardia
Olshansky, B., & Sullivan, R. M. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.074 · Cited by 182 · see citing works
Inappropriate sinus tachycardia
Olshansky, B., & Sullivan, R. M. (2019) · EP Europace · doi:10.1093/europace/euy128 · Cited by 80 · see citing works
Collateral Nervous Damages After Cryoballoon Pulmonary Vein Isolation
Guiot, A., Savouré, A., GODIN, B., & Anselme, F. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02219.x · Cited by 79 · see citing works
Sinus Tachycardia: a Multidisciplinary Expert Focused Review
Mayuga, K. A., Fedorowski, A., Ricci, F., Gopinathannair, R., Dukes, J. W., Gibbons, C., Hanna, P., Sorajja, D., Chung, M., Benditt, D., et al. (2022) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.121.007960 · Cited by 59 · see citing works
Supraventricular Tachycardia—Part I
Lee, K. W., Badhwar, N., & Scheinman, M. M. (2008) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2008.06.002 · Cited by 38 · see citing works
Baruscotti, M., Bianco, E., Bucchi, A., & DiFrancesco, D. (2016) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-015-0097-y · Cited by 37 · see citing works
PTASZYNSKI, P., KACZMAREK, K., RUTA, J., KLINGENHEBEN, T., & WRANICZ, J. K. (2013) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12018 · Cited by 23 · see citing works
Strategies for phrenic nerve preservation during ablation of inappropriate sinus tachycardia
Ibarra-Cortez, S. H., Rodríguez‐Mañero, M., Kreidieh, B., Schurmann, P. A., Dave, A. S., & Valderrábano, M. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.01.021 · Cited by 20 · see citing works
Kanjwal, K., Karabin, B. L., Sheikh, M. A., Kanjwal, Y., & Grubb, B. P. (2010) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-010-9506-4 · Cited by 15 · see citing works
What’s so inappropriate about sinus tachycardia?
OLSHANSKY, B. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01179.x · Cited by 12 · see citing works
Sucu, M., Aytemir, K., & Yorgun, H. (2015) · PubMed Central · doi:10.4022/jafib.1270 · Cited by 8 · see citing works
Catheter Cryoablation for the Treatment of Accessory Pathways
Chan, N. (2013) · doi:10.1002/9781118451793.ch8 · Cited by 2 · see citing works
Sinoatrial Nodal Reentrant Tachycardia
Hafeez, Y., & Grossman, S. A. (2021) · StatPearls
- Authors
- MOREIRA, J. M., CURIMBABA, J., FILHO, H. C., & PIMENTA, J.
- Affiliations
- Hospital do Servidor Público Estadual (BR)
- Universidade Estadual de Campinas (UNICAMP) (BR)
- Corresponding author
- MOREIRA, JOSÉ MARCOS
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2006-02-14
- Volume
- 17
- Issue
- 6
- Pages
- 678-681
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2128956502
- Cited by
- 13
- References
- 12
- Citations by year
- 2022: 1 · 2021: 1 · 2018: 1 · 2016: 2 · 2015: 1 · 2013: 1 · 2012: 2
- FWCI
- 0.47
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Cardiovascular Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- inappropriate sinus tachycardia, atrioventricular reentrant tachycardia, left lateral accessory pathway, radiofrequency catheter ablation complications, narrow QRS tachycardia
- MeSH terms
- Adolescent, Female, Ganglia, Parasympathetic, Heart Conduction System, Heart Rate, Humans, Sinoatrial Node, Tachycardia, Atrioventricular Nodal Reentry, Tachycardia, Sinus, Time Factors, Electrocardiography, Ambulatory, Catheter Ablation, Electrophysiologic Techniques, Cardiac
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review