Characterization of Conduction Recovery Across Left Atrial Linear Lesions in Patients with Paroxysmal and Persistent Atrial Fibrillation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Left atrial (LA) linear lesions are effective in substrate modification for atrial fibrillation (AF). However, achievement of complete conduction block remains challenging and conduction recovery is commonly observed. The aim of the study was to investigate the localization of gap sites of recovered LA linear lesions. Methods and Results: Forty‐eight patients with paroxysmal (n = 26) and persistent/permanent (n = 22) AF underwent repeat ablation after pulmonary vein (PV) isolation and LA linear ablation at the LA roof and/or mitral isthmus due to recurrences of AF or flutter. In 35 patients, conduction through the mitral isthmus line (ML) had recovered whereas roof‐line recovery was observed in 30 patients. The gaps within the ML were distributed to the junction between left inferior PV and left atrial appendage in 66%, the middle part of the ML in 20%, and in 8% to the endocardial aspect of the ML while only 6% of lines showed an epicardial site of recovery. The RL predominantly recovered close to the right superior PV (54%) and less frequently in the mid roof or close to the left PV (both 23%). Reablation of lines required significantly shorter RF durations (ML: 7.24 ± 5.55 minutes vs 24.08 ± 9.38 minutes, RL: 4.24 ± 2.34 minutes vs 11.54 ± 6.49 minutes; P = 0.0001). Patients with persistent/permanent AF demonstrated a significantly longer conduction delay circumventing the complete lines than patients with paroxysmal AF (228 ± 77 ms vs 164 ± 36 ms, P = 0.001). Conclusions: Gaps in recovered LA lines were predominantly located close to the PVs where catheter stability is often difficult to achieve. Shorter RF durations are required for reablation of recovered linear lesions. Conduction times around complete LA lines are significantly longer in patients with persistent/permanent AF as compared to patients with paroxysmal AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Relation between echocardiographically determined left atrial size and atrial fibrillation.
Henry, W. L., Morganroth, J., Pearlman, A. S., Clark, C. E., Redwood, D. R., Itscoitz, S. B., & Epstein, S. E. (1976) · Circulation · doi:10.1161/01.cir.53.2.273 · Cited by 641
Franz, M. R., Karasik, P. L., Li, C., Moubarak, J., & Chavez, M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00385-9 · Cited by 301 · cited 1×
“The study comprised 48 patients with paroxysmal (26) and persistent/permanent (22) AF who underwent repeat electrophysiological study and ablation due to recurrence of either left atrial tachycardia and/or AF.”
Background
Cited by
Left atrial linear lesions are required for successful treatment of persistent atrial fibrillation
Knecht, S., Hocini, M., Wright, M., Lellouche, N., O'Neill, M. D., Matsuo, S., Nault, I., Chauhan, V. S., Makati, K. J., Bevilacqua, M., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn302 · Cited by 259
Self-citationJAÏS, P., MATSUO, S., KNECHT, S., WEERASOORIYA, R., HOCINI, M., SACHER, F., WRIGHT, M., NAULT, I., LELLOUCHE, N., KLEIN, G., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01373.x · Cited by 255
Self-citationKirchhof, P., Bax, J., Blomstrom-Lundquist, C., Calkins, H., Camm, A. J., Cappato, R., Cosio, F., Crijns, H., Diener, H.-C., Goette, A., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp235 · Cited by 202
“Improving feasibility and safety of pulmonary vein isolation The pulmonary veins often do not remain isolated,(25,68,69) and linear left atrial lesions may not provide continuous conduction block.(70) Ongoing trials will test whether complete isolation of pulmonary veins is needed for AF suppression.”
BackgroundPokushalov, E., Romanov, A., Katritsis, D. G., Artyomenko, S., Shirokova, N., Karaskov, A., Mittal, S., & Steinberg, J. S. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.04.016 · Cited by 185
Schreiber, D., Rostock, T., Fröhlich, M., Sultan, A., Servatius, H., Hoffmann, B. A., Lüker, J., Berner, I., Schäffer, B., Wegscheider, K., et al. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001672 · Cited by 175
Self-citation
Metadata
- Authors
- ROSTOCK, T., O'NEILL, M. D., SANDERS, P., ROTTER, M., JAÏS, P., HOCINI, M., TAKAHASHI, Y., SACHER, F., JÖNSSON, A., HSU, L., CLÉMENTY, J., & HAÏSSAGUERRE, M.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2006-08-14
- Volume
- 17
- Issue
- 10
- Pages
- 1106-1111
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2021393814
- Cited by
- 109
- References
- 2
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Conduction Recovery Across Left Atrial Linear Lesions in Patients with Paroxysmal and Persistent Atrial Fibrillation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2006.00585.x
- The paper
- ROSTOCK, T., O'NEILL, M. D., SANDERS, P., ROTTER, M., JAÏS, P., HOCINI, M., TAKAHASHI, Y., SACHER, F., JÖNSSON, A., HSU, L., CLÉMENTY, J., & HAÏSSAGUERRE, M. (2006). Characterization of Conduction Recovery Across Left Atrial Linear Lesions in Patients with Paroxysmal and Persistent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2006.00585.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.