CoChat

Standard Template of Adult Magnetocardiogram

Open access
Kandori, Akihiko, Ogata, Kuniomi, Miyashita, Tsuyoshi, Watanabe, Yasushi, Tanaka, Kimio, Murakami, Masahiro, Oka, Yuji, Takaki, Hiroshi, Hashimoto, Syuji, Yamada, Yuko, Komamura, Kazuo, Shimizu, Wataru, Kamakura, Shiro, Watanabe, Shigeyuki, Yamaguchi, Iwao · 2008 · Annals of Noninvasive Electrocardiology
Cited by 18

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background:We need to know the magnetocardiogram (MCG) features regarding waveform and two‐dimensional current distribution in normal subjects in order to classify the abnormal waveform in patients with heart disease. However, a standard MCG waveform has not been produced yet, therefore, we have first made the standard template MCG waveform. Methods and Results:We used data from 464 normal control subjects' 64‐channel MCGs (268 males, 196 females) to produce a template MCG waveform. The measured data were averaged after shortening or lengthening and normalization. The time interval and amplitude of the averaged data were adjusted to mean values obtained from a database. Furthermore, the current distributions (current arrow maps [CAMs]) were calculated from the produced templates to determine the current distribution pattern. The produced template of the QRS complex had a typical shape in six regions that we defined (M1, M2, M3, M4, M5, and M6). In the P wave, the main current arrow in CAMs pointing in a lower‐left direction appeared in M1. In the QRS complex, the typical wave appeared in each region, and there were two main current arrows in M2 and M5. There were negative T waves in M1, M4, and M5, and positive T waves in M3 and M6, and the main current arrow pointing in a lower‐left direction appeared in M2. Conclusion:Template MCG waveforms were produced. These morphologic features were classified into six regions, and the current distribution was characterized in each region. Consequently, the templates and classifications enable understanding MCG features and writing clinical reports.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1542-474x.2008.00246.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 18

Metadata

Authors
Kandori, A., Ogata, K., Miyashita, T., Watanabe, Y., Tanaka, K., Murakami, M., Oka, Y., Takaki, H., Hashimoto, S., Yamada, Y., Komamura, K., Shimizu, W., Kamakura, S., Watanabe, S., & Yamaguchi, I.
Venue
Annals of Noninvasive Electrocardiology
Publisher
Wiley
Published
2008-10
Volume
13
Issue
4
Pages
391-400
ISSN
  • 1082-720X (ISSN-L)
  • 1542-474X
OpenAlex
W1900854397
Cited by
18
References
4
FWCI
0.44
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standard Template of Adult Magnetocardiogram. https://app.cochat.ai/papers/10.1111/j.1542-474x.2008.00246.x
The paper
Kandori, A., Ogata, K., Miyashita, T., Watanabe, Y., Tanaka, K., Murakami, M., Oka, Y., Takaki, H., Hashimoto, S., Yamada, Y., Komamura, K., Shimizu, W., Kamakura, S., Watanabe, S., & Yamaguchi, I. (2008). Standard Template of Adult Magnetocardiogram. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/j.1542-474x.2008.00246.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.