The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Polyp Miss Rate Determined by Tandem Colonoscopy: A Systematic Review
Abstract
BACKGROUND AND AIMS: Colonoscopy is the best available method to detect and remove colonic polyps and therefore serves as the gold standard for less invasive tests such as virtual colonoscopy. Although gastroenterologists agree that colonoscopy is not infallible, there is no clarity on the numbers and rates of missed polyps. The purpose of this systematic review was to obtain summary estimates of the polyp miss rate as determined by tandem colonoscopy. METHODS: An extensive search was performed within PUBMED, EMBASE, and the Cochrane Library databases to identify studies in which patients had undergone two same-day colonoscopies with polypectomy. Random effects models based on the binomial distribution were used to calculate pooled estimates of miss rates. RESULTS: Six studies with a total of 465 patients could be included. The pooled miss rate for polyps of any size was 22% (95% CI: 19-26%; 370/1,650 polyps). Adenoma miss rate by size was, respectively, 2.1% (95% CI: 0.3-7.3%; 2/96 adenomas > or =10 mm), 13% (95% CI: 8.0-18%; 16/124 adenomas 5-10 mm), and 26% (95% CI: 27-35%; 151/587 adenomas 1-5 mm). Three studies reported data on nonadenomatous polyps: zero of eight nonadenomatous polyps > or =10 mm were missed (0%; 95% CI: 0-36.9%) and 83 of 384 nonadenomatous polyps <10 mm were missed (22%; 95% CI: 18-26%). CONCLUSIONS: Colonoscopy rarely misses polyps > or =10 mm, but the miss rate increases significantly in smaller sized polyps. The available evidence is based on a small number of studies with heterogeneous study designs and inclusion criteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevention of Colorectal Cancer by Colonoscopic Polypectomy
Winawer, S. J., Zauber, A. G., Ho, M. N., O'Brien, M. J., Gottlieb, L. S., Sternberg, S. S., Waye, J. D., Schapiro, M., Bond, J. H., Panish, J. F., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312303292701 · Cited by 4,592
Jemal, A., Tiwari, R. C., Murray, T., Ghafoor, A., Samuels, A., Ward, E., Feuer, E. J., & Thun, M. J. (2004) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.54.1.8 · Cited by 3,984
Interval Estimation for a Binomial Proportion
Brown, L. D., Cai, T. T., & DasGupta, A. (2001) · Statistical Science · doi:10.1214/ss/1009213286 · Cited by 3,538
Reducing Mortality from Colorectal Cancer by Screening for Fecal Occult Blood
Mandel, J. S., Bond, J. H., Church, T. R., Snover, D. C., Bradley, G. M., Schuman, L. M., & Ederer, F. (1993) · New England Journal of Medicine · doi:10.1056/nejm199305133281901 · Cited by 3,229
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Self-citationTowards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Self-citationTowards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Self-citationWINAWER, S. (2003) · Gastroenterology · doi:10.1053/gast.2003.50044 · Cited by 2,143
Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic Adults
Pickhardt, P. J., Choi, J. R., Hwang, I., Butler, J. A., Puckett, M. L., Hildebrandt, H. A., Wong, R. K., Nugent, P. A., Mysliwiec, P. A., & Schindler, W. R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031618 · Cited by 1,972
The Statistical Evaluation of Medical Tests for Classification and Prediction
(2005) · Technometrics · doi:10.1198/tech.2005.s278 · Cited by 1,899
Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies
Rex, D., Cutler, C., Lemmel, G., Rahmani, E., Clark, D., Helper, D., Lehman, G., & Mark, D. (1997) · Gastroenterology · doi:10.1016/s0016-5085(97)70214-2 · Cited by 1,553
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Self-citationBowles, C. J. A., Leicester, R., Romaya, C., Swarbrick, E., Williams, C. B., & Epstein, O. (2004) · Gut · doi:10.1136/gut.2003.016436 · Cited by 617
Colorectal Cancer in Patients Under Close Colonoscopic Surveillance
Robertson, D. J., Greenberg, E. R., Beach, M., Sandler, R. S., Ahnen, D., Haile, R. W., Burke, C. A., Snover, D. C., Bresalier, R. S., McKeown-Eyssen, G., et al. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.05.012 · Cited by 443
Prospective Study of the Frequency and Size Distribution of Polyps Missed by Colonoscopy
Hixson, L. J., Fennerty, M. B., Sampliner, R. E., McGee, D., & Garewal, H. (1990) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/82.22.1769 · Cited by 338
Brooker, J. C., Saunders, B. P., Shah, S. G., Thapar, C. J., Thomas, H. J. W., Atkin, W. S., Cardwell, C. R., & Williams, C. B. (2002) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(02)70034-5 · Cited by 274
Prospective blinded trial of the colonoscopic miss-rate of large colorectal polyps
Hixson, L. J., Fennerty, M. B., Sampliner, R. E., & Garewal, H. S. (1991) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(91)70668-8 · Cited by 273
The pathologic measurement of polyp size is preferable to the endoscopic estimate
Schoen, R. E., Gerber, L. D., & Margulies, C. (1997) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(97)70002-6 · Cited by 184
van Gelder, R. E., Nio, C. Y., Florie, J., Bartelsman, J. F., Snel, P., de Jager, S. W., van Deventer, S. J., Laméris, J. S., Bossuyt, P. M. M., & Stoker, J. (2004) · Gastroenterology · doi:10.1053/j.gastro.2004.03.055 · Cited by 175
Self-citationHyperplastic polyps and colorectal cancer: is there a link?
Jass, J. R. (2004) · Clinical Gastroenterology and Hepatology · doi:10.1016/s1542-3565(03)00284-2 · Cited by 163
Impact of Proximal Colon Retroflexion on Adenoma Miss Rates
Harrison, M., Singh, N., & Rex, D. K. (2004) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2004.04070.x · Cited by 141
Rex, D. K., Chadalawada, V., & Helper, D. J. (2003) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2003.07662.x · Cited by 110
Postić, G., Lewin, D., Bickerstaff, C., & Wallace, M. B. (2002) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2002.07128.x · Cited by 93
Advances in colonic imaging: new endoscopic imaging methods
Dekker, E., & Fockens, P. (2005) · European Journal of Gastroenterology & Hepatology · doi:10.1097/00042737-200508000-00004 · Cited by 39
Self-citation
Cited by
Convolutional Neural Networks for Medical Image Analysis: Full Training or Fine Tuning?
Tajbakhsh, N., Shin, J. Y., Gurudu, S. R., Hurst, R. T., Kendall, C. B., Gotway, M. B., & Liang, J. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2535302 · Cited by 3,277
Bernal, J., Sánchez, F. J., Fernández-Esparrach, G., Gil, D., Rodríguez, C., & Vilariño, F. (2015) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2015.02.007 · Cited by 2,191
Quality Indicators for Colonoscopy and the Risk of Interval Cancer
Kaminski, M. F., Regula, J., Kraszewska, E., Polkowski, M., Wojciechowska, U., Didkowska, J., Zwierko, M., Rupinski, M., Nowacki, M. P., & Butruk, E. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0907667 · Cited by 2,010
Quality indicators for colonoscopy
Rex, D. K., Schoenfeld, P. S., Cohen, J., Pike, I. M., Adler, D. G., Fennerty, M. B., Lieb, J. G., Park, W. G., Rizk, M. K., Sawhney, M. S., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.07.058 · Cited by 1,764
Kvasir-SEG: A Segmented Polyp Dataset
Jha, D., Smedsrud, P. H., Riegler, M. A., Halvorsen, P., de Lange, T., Johansen, D., & Johansen, H. D. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-37734-2_37 · Cited by 1,661
Metadata
- Authors
- van Rijn, J. C., Reitsma, J. B., Stoker, J., Bossuyt, P. M., van Deventer, S. J., & Dekker, E.
- Venue
- The American Journal of Gastroenterology
- Published
- 2006-02
- Volume
- 101
- Issue
- 2
- Pages
- 343-350
- ISSN
- 0002-9270 (ISSN-L)
- 1572-0241
- OpenAlex
- W2063979222
- Cited by
- 1,344
- References
- 24
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.