Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 199

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Diagnostic Ionizing Radiation Exposure in a Population-Based Cohort of Patients with Inflammatory Bowel Disease

Open access
Peloquin, Joanna M., Pardi, Darrell S., Sandborn, William J., Fletcher, Joel G., McCollough, Cynthia H., Schueler, Beth A., Kofler, James A., Enders, Felicity T.B., Achenbach, Sara J., Loftus, Jr, Edward V. · 2008 · The American Journal of Gastroenterology

Abstract

OBJECTIVE: For diagnosis, assessing disease activity, complications and extraintestinal manifestations, and monitoring response to therapy, patients with inflammatory bowel disease undergo many radiological studies employing ionizing radiation. However, the extent of radiation exposure in these patients is unknown. METHODS: A population-based inception cohort of 215 patients with inflammatory bowel disease from Olmsted County, Minnesota, diagnosed between 1990 and 2001, was identified. The total effective dose of diagnostic ionizing radiation was estimated for each patient. Linear regression was used to assess the median total effective dose since symptom onset. RESULTS: The number of patients with Crohn's disease and ulcerative colitis was 103 and 112, with a mean age at diagnosis of 38.6 and 39.4 yr, respectively. Mean follow-up was 8.9 yr for Crohn's disease and 9.0 yr for ulcerative colitis. Median total effective dose for Crohn's disease was 26.6 millisieverts (mSv) (range, 0-279) versus 10.5 mSv (range, 0-251) for ulcerative colitis (P < 0.001). Computed tomography accounted for 51% and 40% of total effective dose, respectively. Patients with Crohn's disease had 2.46 times higher total effective dose than ulcerative colitis patients (P= 0.001), adjusting for duration of disease. CONCLUSIONS: Annualizing our data, the radiation exposure in the inflammatory bowel disease population was equivalent to the average annual background radiation dose from naturally occurring sources in the U.S. (3.0 mSv). However, a subset of patients had substantially higher doses. The development of imaging management guidelines to minimize radiation dose, dose-reduction techniques in computed tomography, and faster, more robust magnetic resonance techniques are warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1572-0241.2008.01920.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 199

Metadata

Authors
Peloquin, J. M., Pardi, D. S., Sandborn, W. J., Fletcher, J. G., McCollough, C. H., Schueler, B. A., Kofler, J. A., Enders, F. T. B., Achenbach, S. J., & Loftus, Jr.
Venue
The American Journal of Gastroenterology
Published
2008-08
Volume
103
Issue
8
Pages
2015-2022
ISSN
  • 0002-9270 (ISSN-L)
  • 1572-0241
OpenAlex
W2058453123
Cited by
199
References
5
FWCI
14.34
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Ionizing Radiation Exposure in a Population-Based Cohort of Patients with Inflammatory Bowel Disease. https://app.cochat.ai/papers/10.1111/j.1572-0241.2008.01920.x
The paper
Peloquin, J. M., Pardi, D. S., Sandborn, W. J., Fletcher, J. G., McCollough, C. H., Schueler, B. A., Kofler, J. A., Enders, F. T. B., Achenbach, S. J., & Loftus, Jr. (2008). Diagnostic Ionizing Radiation Exposure in a Population-Based Cohort of Patients with Inflammatory Bowel Disease. The American Journal of Gastroenterology. https://doi.org/10.1111/j.1572-0241.2008.01920.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.