A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years: I. Implant‐supported FPDs
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Objectives: The objective of this systematic review was to assess the 5‐ and 10‐year survival of implant supported fixed partial dentures (FPDs) and to describe the incidence of biological and technical complications. Methods: An electronic MEDLINE search complemented by manual searching was conducted to identify prospective and retrospective cohort studies on FPDs with a mean follow‐up time of at least 5 years. Patients had to have been examined clinically at the follow‐up visit. Assessment of the identified studies and data abstraction was performed independently by two reviewers. Failure and complication rates were analyzed using random‐effects Poisson regression models to obtain summary estimates of 5‐ and 10‐year survival proportions. Results: The search provided 3844 titles and 560 abstracts. Full‐text analysis was performed for 176 articles resulting in 21 studies that met the inclusion criteria. Meta‐analysis of these studies indicated an estimated survival of implants in implant‐supported FPDs of 95.4% (95 percent confidence interval (95% CI): 93.9–96.5%) after 5 and 92.8% (95% CI: 90–94.8%) after 10 years. The survival rate of FPDs supported by implants was 95% (95% CI: 92.2–96.8%) after 5 and 86.7% (95% CI: 82.8–89.8%) after 10 years of function. Only 61.3% (95% CI: 55.3–66.8%) of the patients were free of any complications after 5 years. Peri‐implantitis and soft tissue complications occurred in 8.6% (95% CI: 5.1–14.1%) of FPDs after 5 years. Technical complications included implant fractures, connection‐related and suprastructure‐related complications. The cumulative incidence of implant fractures after 5 years was 0.4% (95% CI: 0.1–1.2%). After 5 years, the cumulative incidence of connection‐related complications (screw loosening or fracture) was 7.3% and 14% for suprastructure‐related complications (veneer and framework fracture). Conclusion: Despite a high survival of FPDs, biological and technical complications are frequent. This, in turn, means that substantial amounts of chair time have to be accepted by the clinician following the incorporation of implant‐supported FPDs. More studies with follow‐up times of 10 and more years are needed as only few studies have described the long‐term outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
Adell, R., Lekholm, U., Rockler, B., & Brånemark, P.-I. (1981) · International Journal of Oral Surgery · doi:10.1016/s0300-9785(81)80077-4 · Cited by 4,816
The long-term efficacy of currently used dental implants: a review and proposed criteria of success.
Albrektsson, T. O., Zarb, G. A., Worthington, P., & Eriksson, A. R. (1986) · PubMed · Cited by 3,691
Kirkwood, B. R., & Sterne, J. A. C. (2014) · Bristol Research (University of Bristol) · Cited by 2,820
Systematic Reviews in Health Care: Meta‐Analysis in Context
(2001) · doi:10.1002/9780470693926 · Cited by 1,693
Buser, D., Mericske‐stern, R., Pierre Bernard, J. P., Behneke, A., Behneke, N., Hirt, H. P., Belser, U. C., & Lang, N. P. (1997) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1997.080302.x · Cited by 1,286
Self-citationEsposito, M., Hirsch, J., Lekholm, U., & Thomsen, P. (1998) · European Journal of Oral Sciences · doi:10.1046/j.0909-8836..t01-2-.x · Cited by 1,274
Egger, M., Jüni, P., Bartlett, C., Holenstein, F., & Sterne, J. (2003) · Health Technology Assessment · doi:10.3310/hta7010 · Cited by 1,181
Self-citationBerglundh, T., Persson, L., & Klinge, B. (2002) · Journal of Clinical Periodontology · doi:10.1034/j.1600-051x.29.s3.12.x · Cited by 1,086
Systematic reviews of evaluations of prognostic variables
Altman, D. G. (2001) · BMJ · doi:10.1136/bmj.323.7306.224 · Cited by 756
Buser, D., Weber, H. ‐., & Lang, N. P. (1990) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1990.010105.x · Cited by 724
Self-citationBrägger, U., Aeschlimann, S., Bürgin, W., Hämmerle, C. H. F., & Lang, N. P. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.012001026.x · Cited by 395
Self-citationLang, N. P., Pjetursson, B. E., Tan, K., Brägger, U., Egger, M., & Zwahlen, M. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01118.x · Cited by 359
Self-citationKaroussis, I. K., Brägger, U., Salvi, G. E., Bürgin, W., & Lang, N. P. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.00983.x · Cited by 344
Self-citationNaert, I. E., Koutsikakis, G., Duyck, J. A. J., Quirynen, M., Jacobs, R., & van Steenberghe, D. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130406.x · Cited by 232
Mengel, R., Schröder, T., & Flores‐de‐Jacoby, L. (2001) · Journal of Periodontology · doi:10.1902/jop.2001.72.8.977 · Cited by 112
Naert, I. E., Koutsikakis, G., Quirynen, M., Duyck, J. A. J., van Steenberghe, D., & Jacobs, R. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130407.x · Cited by 95
Cochran, D. L. (1996) · Annals of Periodontology · doi:10.1902/annals.1996.1.1.707 · Cited by 94
Long‐term evaluation of single crystal sapphire implants as abutments in fixed prosthodontics
Fartash, B., & Arvidson, K. (1997) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.1997.tb00008.x · Cited by 50
Longitudinal studies of implant systems
Fiorellini, J. P., Martuscelli, G., & Weber, H. P. (1998) · Periodontology 2000 · doi:10.1111/j.1600-0757.1998.tb00130.x · Cited by 42
Cited by
A systematic review of the 5‐year survival and complication rates of implant‐supported single crowns
Jung, R. E., Pjetursson, B. E., Glauser, R., Zembic, A., Zwahlen, M., & Lang, N. P. (2008) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01453.x · Cited by 1,063
Self-citationE. Jung, R., Zembic, A., Pjetursson, B. E., Zwahlen, M., & S. Thoma, D. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02547.x · Cited by 1,019
Self-citationPjetursson, B. E., Thoma, D., Jung, R., Zwahlen, M., & Zembic, A. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02546.x · Cited by 915
Self-citationPjetursson, B. E., Brägger, U., Lang, N. P., & Zwahlen, M. (2007) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01439.x · Cited by 786
Self-citationMoraschini, V., Poubel, L. A. D. C., Ferreira, V. F., & Barboza, E. D. S. P. (2015) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2014.10.023 · Cited by 729
Metadata
- Authors
- Pjetursson, B. E., Tan, K., Lang, N. P., Brägger, U., Egger, M., & Zwahlen, M.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2004-10-12
- Volume
- 15
- Issue
- 6
- Pages
- 625-642
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W4231512841
- Cited by
- 486
- References
- 19
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.