Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 257

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Early loading of non‐submerged titanium implants with a sandblasted and acid‐etched surface: 5‐year results of a prospective study in partially edentulous patients

Bornstein, Michael M., Schmid, Bruno, Belser, Urs C., Lussi, Adrian, Buser, Daniel·2005·Clinical Oral Implants Research

Abstract

Objectives: The aim of this prospective cohort study was to evaluate the success rate of titanium screw‐type implants with the sandblasted and acid‐etched (SLA) surface loaded early, after 6 weeks of healing. Material and methods: A total of 104 implants were inserted into posterior sites of 51 partially edentulous patients exhibiting bone densities of class I–III. After a healing period of 6 weeks, all implants were functionally loaded with cemented crowns or fixed partial dentures. The patients were recalled at 3, 12, 24, 36, 48 and 60 months for clinical and radiographic examination. Results: One implant failed to integrate during healing, and three implants were lost to follow‐up and were considered drop‐outs. The remaining 100 implants showed favorable clinical and radiographic findings at the 5‐year examination. The peri‐implant soft tissues were stable over time; the mean probing depths and mean attachment levels did not change during the follow‐up period. None of the radiographs exhibited signs of continuous peri‐implant radiolucency, which confirmed ankylotic stability for all 100 implants. The measurement of the bone crest levels (DIB values) indicated stability as well. Based on strict success criteria, all 100 implants were considered successfully integrated, resulting in a 5‐year success rate of 99%. Conclusion: This prospective study using an early loading protocol with 6 weeks of healing demonstrated that titanium implants with the SLA surface can achieve and maintain successful tissue integration with high predictability for at least 5 years of follow‐up in selected patients and sites.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2005.01209.x

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 257

Metadata

Authors
Bornstein, M. M., Schmid, B., Belser, U. C., Lussi, A., & Buser, D.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2005-11-14
Volume
16
Issue
6
Pages
631-638
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W1934032588
Cited by
257
References
34
FWCI
18.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early loading of non‐submerged titanium implants with a sandblasted and acid‐etched surface: 5‐year results of a prospective study in partially edentulous patients. https://app.cochat.ai/papers/10.1111/j.1600-0501.2005.01209.x
The paper
Bornstein, M. M., Schmid, B., Belser, U. C., Lussi, A., & Buser, D. (2005). Early loading of non‐submerged titanium implants with a sandblasted and acid‐etched surface: 5‐year results of a prospective study in partially edentulous patients. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2005.01209.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.