Implant micromotion is related to peak insertion torque and bone density
Abstract
Objectives: Measuring peak insertion torque in relation to different bone densities, the present study seeks to determine whether micromotion at the interface is related to primary stability achieved by increasing insertion torque. Material and methods: A total of 120 Ti‐Bone implants were placed in fresh bovine bone samples representing three density categories: hard, normal and soft (HNS). Five groups of peak insertion torque (20, 35, 45, 70 and 100 N/cm) were evaluated in the three bone density categories noted. Customized electronic equipment connected to a PC was used to register the peak and other insertion torque data. A loading device, consisting of a digital force gauge and a digital micrometer, was used to measure the micromovements of the implant during the application of 20, 25 and 30 N lateral forces. The data were analyzed for statistical significance by ANOVA and Spearman's rank correlation coefficient tests. Results: A statistically significant difference between implant micromobility placed with different levels of torque and in different bone densities was demonstrated by ANOVA. Spearman's rank correlation coefficient showed a high dependency between the peak insertion torque and the observed micromovement. Particularly, in soft bone, it was not possible to achieve more than 35 N/cm of peak insertion torque. Conclusions: Results showed that increasing the peak insertion torque reduces the level of implant micromotion. In addition, micromotion in soft bone was found to be consistently high, which could lead to the failure of osseointegration. Thus, immediate functional loading of implants in soft bone should be considered with caution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perren, S. M. (2002) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.84b8.13752 · Cited by 1,247
Szmukler-Moncler, S., Salama, H., Reingewirtz, Y., & Dubruille, J. H. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199822)43:2<192::aid-jbm14>3.0.co;2-k · Cited by 794
Finite element analysis of six endosseous implants
Rieger, M. R., Mayberry, M., & Brose, M. O. (1990) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(90)90325-7 · Cited by 181
Malone, A. A. (2003) · Injury · doi:10.1016/s0020-1383(03)00107-4 · Cited by 122
In Vitro Evaluation of Horizontal Implant Micromovement in Bone Specimen With Contact Endoscopy
Engelke, W., Decco, O. A., Rau, M., et al. (2004) · Implant Dentistry · doi:10.1097/01.id.0000116457.03989.01 · Cited by 81
Cited by
Schwarz, F., Derks, J., Monje, A., & Wang, H. (2018) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12954 · Cited by 1,066
Corrosion of Metallic Biomaterials: A Review
Eliaz, N. (2019) · Materials · doi:10.3390/ma12030407 · Cited by 984
Schwarz, F., Derks, J., Monje, A., & Wang, H. (2018) · Journal of Periodontology · doi:10.1002/jper.16-0350 · Cited by 723
Javed, F., Ahmed, H. B., Crespi, R., & Romanos, G. E. (2013) · Interventional Medicine and Applied Science · doi:10.1556/imas.5.2013.4.3 · Cited by 457
Basis of bone metabolism around dental implants during osseointegration and peri‐implant bone loss
Insua, A., Monje, A., Wang, H., & Miron, R. J. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36060 · Cited by 277
Metadata
- Authors
- Trisi, P., Perfetti, G., Baldoni, E., Berardi, D., Colagiovanni, M., & Scogna, G.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2009-04-12
- Volume
- 20
- Issue
- 5
- Pages
- 467-471
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2010268320
- Cited by
- 285
- References
- 5
- FWCI
- 11.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implant micromotion is related to peak insertion torque and bone density. https://app.cochat.ai/papers/10.1111/j.1600-0501.2008.01679.x
- The paper
- Trisi, P., Perfetti, G., Baldoni, E., Berardi, D., Colagiovanni, M., & Scogna, G. (2009). Implant micromotion is related to peak insertion torque and bone density. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2008.01679.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.