Titanium allergy: could it affect dental implant integration?
The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
Purpose: Degradation products of metallic biomaterials including titanium may result in metal hypersensitivity reaction. Hypersensitivity to biomaterials is often described in terms of vague pain, skin rashes, fatigue and malaise and in some cases implant loss. Recently, titanium hypersensitivity has been suggested as one of the factors responsible for implant failure. Although titanium hypersensitivity is a growing concern, epidemiological data on incidence of titanium‐related allergic reactions are still lacking. Materials and methods: A computer search of electronic databases primarily MEDLINE and PUBMED was performed with the following key words: ‘titanium hypersensitivity’, ‘titanium allergy’, ‘titanium release’ without any language restriction. Manual searches of the bibliographies of all the retrieved articles were also performed. In addition, a complementary hand search was also conducted to identify recent articles and case reports. Results: Most of the literature comprised case reports and prospective in vivo/in vitro trials. One hundred and twenty‐seven publications were selected for full text reading. The bulk of the literature originated from the orthopaedic discipline, reporting wear debris following knee/hip arthroplasties. The rest comprised osteosynthesis (plates/screws), oral implant/dental materials, dermatology/cardiac‐pacemaker, pathology/cancer, biomaterials and general reports. Conclusion: This review of the literature indicates that titanium can induce hypersensitivity in susceptible patients and could play a critical role in implant failure. Furthermore, this review supports the need for long‐term clinical and radiographic follow‐up of all implant patients who are sensitive to metals. At present, we know little about titanium hypersensitivity, but it cannot be excluded as a reason for implant failure. To cite this article: Siddiqi A, Payne AGT, De Silva RK, Duncan WJ. Titanium allergy: could it affect dental implant integration? Clin. Oral Impl. Res. 22, 2011; 673–680 doi: 10.1111/j.1600‐0501.2010.02081.x
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406 · cited 1×
“The precise role of surface chemistry and topography on the early events of osseointegration remain poorly understood (Le Guéhennec et al. 2007).”
BackgroundEffects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462 · cited 1×
“A recent systemic review concluded that the surface topography influences bone response at the micrometre level and even in some cases at nanometre level (Wennerberg & Albrektsson 2009).”
BackgroundEsposito, M., Hirsch, J., Lekholm, U., & Thomsen, P. (1998) · European Journal of Oral Sciences · doi:10.1046/j.0909-8836..t01-2-.x · Cited by 1,274 · cited 3×
“Implant failure during the initial healing period and after osseointegration has been extensively reviewed in the literature (Friberg et al. 1991; van Steenberghe & Quirynen 1993; Esposito et al. 1998a, 1998b; Montes et al. 2007; Alvim-Pereira et al. 2008).”
BackgroundBiological factors contributing to failures of osseointegrated oral implants, (II). Etiopathogenesis
Esposito, M., Hirsch, J., Lekholm, U., & Thomsen, P. (1998) · European Journal of Oral Sciences · doi:10.1046/j.0909-8836..t01-6-.x · Cited by 1,176 · cited 3×
“Implant failure during the initial healing period and after osseointegration has been extensively reviewed in the literature (Friberg et al. 1991; van Steenberghe & Quirynen 1993; Esposito et al. 1998a, 1998b; Montes et al. 2007; Alvim-Pereira et al. 2008).”
BackgroundMetal Sensitivity in Patients with Orthopaedic Implants
Hallab, N., Merritt, K., & Jacobs, J. J. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200103000-00017 · Cited by 935 · cited 4×
“The prevalence of metal sensitivity among the general population ranges from 10% to 15%, but this increases to 25% in patients with a well-functioning implant (Hallab et al. 2001).”
BackgroundInfluentialURBAN, R. M., JACOBS, J. J., TOMLINSON, M. J., GAVRILOVIC, J., BLACK, J., & PEOC'H, M. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200004000-00002 · Cited by 787 · cited 1×
“Transport of titanium particles via the lymphatics to the regional lymph nodes has been re- ported (Onodera et al. 1993), and was considered a major route for dissemination of wear debris (Harmsen et al. 1985; Urban et al. 2000).”
BackgroundThe diagnosis and treatment of peri‐implantitis
Mombelli, A., & Lang, N. P. (1998) · Periodontology 2000 · doi:10.1111/j.1600-0757.1998.tb00124.x · Cited by 684 · cited 1×
“Many reasons for implant failure have been reported in the literature (Tonetti & Schmid 1994; Esposito et al. 1998a, 1998b; Mombelli & Lang 1998; Piattelli et al. 1998; Tonetti 1998).”
BackgroundMerian, E. (1980) · Chemosphere · doi:10.1016/0045-6535(80)90105-8 · Cited by 623
Dental implant failure rates and associated risk factors.
Moy, P. K., Medina, D., Shetty, V., & Aghaloo, T. L. (2005) · PubMed · Cited by 608
Cited by
Heitz‐Mayfield, L. J. A., & Salvi, G. E. (2018) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12953 · Cited by 383
Heitz‐Mayfield, L. J. A., & Salvi, G. E. (2018) · Journal of Periodontology · doi:10.1002/jper.16-0488 · Cited by 307
Matusiewicz, H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.027 · Cited by 270
Dental implants in the medically compromised patient
Diz, P., Scully, C., & Sanz, M. (2013) · Journal of Dentistry · doi:10.1016/j.jdent.2012.12.008 · Cited by 254
Nanotechnology-based biomaterials for orthopaedic applications: Recent advances and future prospects
Kumar, S., Nehra, M., Kedia, D., Dilbaghi, N., Tankeshwar, K., & Kim, K.-H. (2020) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.110154 · Cited by 246
Titanium as a Reconstruction and Implant Material in Dentistry: Advantages and Pitfalls
Özcan, M., & Hämmerle, C. (2012) · Materials · doi:10.3390/ma5091528 · Cited by 229
“It should be noted that no material can be considered universally biocompatible and this does not exclude titanium [85].”
BackgroundInfluentialMombelli, A., Hashim, D., & Cionca, N. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13305 · Cited by 213
Revathi, A., Borrás, A. D., Muñoz, A. I., Richard, C., & Manivasagam, G. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.02.159 · Cited by 182
Stem cells in dentistry – Part II: Clinical applications
Egusa, H., Sonoyama, W., Nishimura, M., Atsuta, I., & Akiyama, K. (2012) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2012.10.001 · Cited by 180
“Furthermore, recent reports have raised the possibility of metal sensitivity after exposure to titanium in some patients under certain circumstances [79,80].”
BackgroundNanomodified Peek Dental Implants: Bioactive Composites and Surface Modification—A Review
Najeeb, S., Khurshid, Z., Matinlinna, J. P., Siddiqui, F., Nassani, M. Z., & Baroudi, K. (2015) · International Journal of Dentistry · doi:10.1155/2015/381759 · Cited by 175
“Moreover, studies have documented very rare cases of patients developing hypersensitivity to titanium dental implants [16, 17].”
BackgroundApaza‐Bedoya, K., Tarce, M., Benfatti, C. A. M., Henriques, B., Mathew, M. T., Teughels, W., & Souza, J. C. M. (2017) · Journal of Periodontal Research · doi:10.1111/jre.12469 · Cited by 168
Metadata
- Authors
- Siddiqi, A., Payne, A. G. T., De Silva, R. K., & Duncan, W. J.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2011-01-20
- Volume
- 22
- Issue
- 7
- Pages
- 673-680
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2127407685
- Cited by
- 222
- References
- 62
- FWCI
- 14.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.