CoChat

Probing force and the relationship of the probe tip to the periodontal tissues

Van Der Velden, U. · 1979 · Journal of Clinical Periodontology
Cited by 236

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Recently an increasing pocket depth was found to be related to an increasing probing force. The purpose of the present study was to investigate whether or not a plateau value in pocket depth measurements exists and to study, with different probing forces, the location of the tip of the probe in relation to the periodontal fibers and the alveolar bone. Two groups of patients were selected for this study; in one group a number of teeth had to be extracted for periodontal reasons (the extraction group) and in the other a single periodontal surgical procedure was required (the surgery group). All patients received preliminary treatment consisting of plaque control and removal of subgingival deposits. At the time of the investigation the gingival condition was assessed by means of a new index, the Periodontal Pocket Bleeding Index (P.P.B.I.) The criteria were: 0 ‐ no bleeding of the pocket after probing with a force of 0.75N, and 1 ‐ bleeding of the pocket within 30 sec after probing with a force of 0.75N. After local anesthesia in the extraction group, reference marks parallel to the long axis of the experimental teeth were cut with a cylindrical diamond burr. By means of the pressure probe, pocket depth measurements were performed with increasing forces of 0.50, 0.75, 1.00 and 1.25N. After extraction and staining of the remnants of the periodontal fibers, the distance from the most coronal intact connective tissue fibers to the most apical point of the reference marks was measured. In the surgery group using the same pressure probe, interproximal measurements with increasing forces of 0.50, 0.75, 1.00 and 1.25N were made from the apical border of the restorations to the bottom of the pocket. The same measurement, this time to the crest of the alveolar bone, was repeated after a flap had been raised. Results with the P.P.B.I. showed that oral hygiene procedures resulted in a mean index of 0.36 in the surgery group and 0.43 in the extraction group. The results of the present study indicated that 1) using a probe of 0.63 mm diameter, the optimal force level for clinical pocket depth measurements is 0.75N, 2) a force of 0.75N is clinically well tolerated and meets with few objections from patients, 3) when a probing force of 0.75N is used the tip of the probe in both shallow and deep periodontal pockets is located at the most coronal intact connective tissue fibers, 4) a plateau value in pocket depth measurements is found when a probing force of 1.25N is employed, and 5) the mean width of the connective tissue attachment is approximately 1.9 mm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-051x.1979.tb02189.x

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 236

Metadata

Authors
Van Der Velden, U.
Venue
Journal of Clinical Periodontology
Publisher
Wiley
Published
1979-04
Volume
6
Issue
2
Pages
106-114
ISSN
  • 0303-6979 (ISSN-L)
  • 1600-051X
OpenAlex
W2009669931
Cited by
236
References
14
FWCI
13.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.