Sick Building Syndrome (SBS) in Office Workers and Facial Skin Symptoms among VDT-Workers in Relation to Building and Room Characteristics: Two Case-Referent Studies
The DOI matches its Crossref record.
Abstract
In two case-referent studies the associations between questionnaire symptom reports, expressed as SBS (Sick Building Syndrome) in office workers or facial skin symptoms among VDT-workers, and physical data from offices in 160 buildings were investigated. The results show that low outdoor airflow rate and presence of certain pollution sources, such as copying machines, tended to be associated with an elevated prevalence of SBS. Buildings built or remodeled between 1977 and 1986, low-rise buildings with a horizontal roof and a foundation of the type “concrete slab on the ground”, as well as rooms with flourescent tube lighting with metal shields were also associated with higher SBS risks. A number of factors were associated with an overrepresentation of skin symptoms among VDT-workers such as type of foundation (concrete slab on the ground and crawlspace), the frequency of floor cleaning and type of lighting (fluorescent tubes with glass/plastic shields). It has not been possible to establish conclusive explanations for these associations. The difference in associations between building factors and S B S, and between building factors and skin symptoms among VD Tworkers points to different etiologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Self-citationWargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Self-citationOrganic compounds in indoor air—their relevance for perceived indoor air quality?
Wolkoff, P., & Nielsen, G. D. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00244-8 · Cited by 369
Metadata
- Authors
- Sundell, J., Lindvall, T., Stenberg, B., & Wall, S.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 1994-06
- Volume
- 4
- Issue
- 2
- Pages
- 83-94
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2135825134
- Cited by
- 56
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sick Building Syndrome (SBS) in Office Workers and Facial Skin Symptoms among VDT-Workers in Relation to Building and Room Characteristics: Two Case-Referent Studies. https://app.cochat.ai/papers/10.1111/j.1600-0668.1994.t01-2-00003.x
- The paper
- Sundell, J., Lindvall, T., Stenberg, B., & Wall, S. (1994). Sick Building Syndrome (SBS) in Office Workers and Facial Skin Symptoms among VDT-Workers in Relation to Building and Room Characteristics: Two Case-Referent Studies. Indoor Air. https://doi.org/10.1111/j.1600-0668.1994.t01-2-00003.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.