Are We Measuring the Relevant Indoor Pollutants?
The DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Abstract
Abstract Concentrations of volatile organic compounds (VOCs) measured indoors may exceed their odor thresholds, but are usually far below TLV estimates. Even applying additivity to eye and airway irritation effects, it is difficult to rationalize increased sick building syndrome (SBS) symptoms by exposure to generally chemically inert VOCs in the indoor environment. Several studies suggest that chemical reactions in indoor air are linked with SBS symptoms and the examination of these reactions may be necessary in order to understand the role of VOCs as causative agents of SBS symptoms. The usual evaluation of odor annoyance of VOCs based on odor thresholds should be modified, taking into account the large variation of individual human odor thresholds for single substances, and specific additivity phenomena even at subthreshold levels of VOCs. The conclusion of this review is that chemical reactions between oxidizable VOCs and oxidants, such as ozone and possibly nitrogen oxides, can form irritants which may be responsible for the reported symptoms. Compounds adsorbed to particles may also contribute to SBS symptoms. The individual effects of indoor pollutants may act in concert with temperature and relative humidity. New analytical methods are required to measure the oxidative and reactive species or specific markers thereof in indoor air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Environmental Science and Technology
Jauhari, V., Swarup, R., Porter, Pandey, & Mishra, S. (1992) · Medical Entomology and Zoology · Cited by 1,605
Gas-phase tropospheric chemistry of organic compounds: A review
Atkinson, R. (1990) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(90)90438-s · Cited by 1,157
Concentrations of Volatile Organic Compounds in Indoor Air - A Review
Brown, S. K., Sim, M. R., Abramson, M. J., & Gray, C. N. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00007.x · Cited by 559
A detailed mechanism for the gas-phase atmospheric reactions of organic compounds
Carter, W. P. L. (1990) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(90)90005-8 · Cited by 538
The Nose, upper airway physiology and the atmospheric environment
Proctor, D. F., & Andersen, I. (1982) · Elsevier eBooks · Cited by 513
Human reactions to low concentrations of volatile organic compounds
Mølhave, L., Bach, B., & Pedersen, O. F. (1986) · Environment International · doi:10.1016/0160-4120(86)90027-9 · Cited by 441
Sensory Irritation by Airborne Chemicals
Alarie, Y. (1973) · CRC Critical Reviews in Toxicology · doi:10.3109/10408447309082020 · Cited by 416
Effect of low concentrations of ozone on inhaled allergen responses in asthmatic subjects
MOLFINO, N. (1991) · The Lancet · doi:10.1016/0140-6736(91)90346-q · Cited by 394
Interaction between chemoreceptive modalities of odour and irritation
Cain, W. S., & Murphy, C. L. (1980) · Nature · doi:10.1038/284255a0 · Cited by 353
Formation of OH radicals in the gas phase reactions of O3 with a series of terpenes
Atkinson, R., Aschmann, S. M., Arey, J., & Shorees, B. (1992) · Journal of Geophysical Research: Atmospheres · doi:10.1029/92jd00062 · Cited by 349
Cited by
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Jones, A. P. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00272-1 · Cited by 1,481
Wargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507
Association of domestic exposure to volatile organic compounds with asthma in young children
Rumchev, K. (2004) · Thorax · doi:10.1136/thx.2003.013680 · Cited by 466
“Since the present study examined the risk factors for asthma, it is possible that families with a knowledge or risk of asthma were more likely to agree to participate. The most important risk factor for asthma is atopy. However, the proportion of children with atopy and the proportion of children with an atopic parent…”
ResultOrganic compounds in indoor air—their relevance for perceived indoor air quality?
Wolkoff, P., & Nielsen, G. D. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00244-8 · Cited by 369
Self-citationWolkoff, P., Wilkins, C. K., Clausen, P. A., & Nielsen, G. D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00393.x · Cited by 348
Self-citationUhde, E., & Salthammer, T. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.05.082 · Cited by 347
Indoor air pollutants in office environments: Assessment of comfort, health, and performance
Wolkoff, P. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.08.001 · Cited by 342
Self-citationIndoor secondary pollutants from cleaning product and air freshener use in the presence of ozone
Singer, B. C., Coleman, B. K., Destaillats, H., Hodgson, A. T., Lunden, M. M., Weschler, C. J., & Nazaroff, W. W. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.06.005 · Cited by 330
Formaldehyde in the Ambient Atmosphere: From an Indoor Pollutant to an Outdoor Pollutant?
Salthammer, T. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201205984 · Cited by 309
Biological treatment of indoor air for VOC removal: Potential and challenges
Guieysse, B., Hort, C., Platel, V., Munoz, R., Ondarts, M., & Revah, S. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.03.005 · Cited by 308
Risk in cleaning: chemical and physical exposure
Wolkoff, P., Schneider, T., Kildesø, J., Degerth, R., Jaroszewski, M., & Schunk, H. (1998) · Science of The Total Environment · doi:10.1016/s0048-9697(98)00110-7 · Cited by 287
Self-citationVolatile Organic Compounds: Do they present a risk to our health?
Rumchev, K., Brown, H., & Spickett, J. (2007) · Reviews on Environmental Health · doi:10.1515/reveh.2007.22.1.39 · Cited by 249
Chemistry in indoor environments: 20 years of research
Weschler, C. J. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2011.00713.x · Cited by 206
Barro, R., Regueiro, J., Llompart, M., & Garcia-Jares, C. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.10.117 · Cited by 198
Production of mycotoxins on artificially and naturally infested building materials
Nielsen, K. F., Gravesen, S., Nielsen, P. A., Andersen, B., Thrane, U., & Frisvad, J. C. (1999) · Mycopathologia · doi:10.1023/a:1007038211176 · Cited by 195
“• Microbial volatile organic compounds (MVOCs) released from the fungi during growth [18–22].”
BackgroundCan ornamental potted plants remove volatile organic compounds from indoor air? — a review
Dela Cruz, M., Christensen, J. H., Thomsen, J. D., & Müller, R. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-3240-x · Cited by 190
“If VOC concentrations are to be decreased to below odour thresholds as suggested by Wolkoff et al. (1997) it may be necessary to see the potential of VOC removal at very low concentrations.”
Fan, Z., Lioy, P., Weschler, C., Fiedler, N., Kipen, H., & Zhang, J. (2003) · Environmental Science & Technology · doi:10.1021/es026231i · Cited by 188
Building Pathology, Investigation of Sick Buildings — VOC Emissions
Yu, C. W. F., & Kim, J. T. (2010) · Indoor and Built Environment · doi:10.1177/1420326x09358799 · Cited by 183
Bako-Biro, Z., Wargocki, P., Weschler, C. J., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00218.x · Cited by 180
The influence of photocatalytic interior paints on indoor air quality
Auvinen, J., & Wirtanen, L. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.01.031 · Cited by 166
Photocatalytic surface reactions on indoor wall paint
Salthammer, T., & Fuhrmann, F. (2007) · Environmental Science & Technology · doi:10.1021/es070057m · Cited by 153
Indoor air pollutants in schools: nasal patency and biomarkers in nasal lavage
Norbäck, D., Wålinder, R., Wieslander, G., Smedje, G., Erwall, C., & Venge, P. (2000) · Allergy · doi:10.1034/j.1398-9995.2000.00353.x · Cited by 102
Gallego, E., Roca, F. J., Perales, J. F., & Guardino, X. (2011) · Sick Building Syndrome · doi:10.1007/978-3-642-17919-8_16 · Cited by 9
Metadata
- Authors
- Wolkoff, P., Clausen, P. A., Jensen, B., Nielsen, G. D., & Wilkins, C. K.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 1997-06
- Volume
- 7
- Issue
- 2
- Pages
- 92-106
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2144651167
- Cited by
- 180
- References
- 79
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.