The performance and subjective responses of call-center operators with new and used supply air filters at two outdoor air supply rates
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
UNLABELLED: A 2 x 2 replicated field intervention experiment was conducted in a call-center providing a telephone directory service: outdoor air supply rate was adjusted to be 8% or 80% of the total airflow of 430 l/s (3.5 /h) and the supply air filters were either new or had been in place for 6 months. One of these independent variables was changed each week for 8 weeks. The interventions did not affect room temperature, relative humidity or noise level. The 26 operators were blind to conditions and each week returned questionnaires recording their environmental perceptions and Sick Building Syndrome (SBS) symptoms. Their performance was continuously monitored by recording the average talk-time every 30 min. Replacing a used filter with a clean filter reduced talk-time by about 10% at the high ventilation rate but had no significant effect at the low rate. Increasing the outdoor air supply rate reduced talk-time by 6% with a new filter in place but increased talk-time by 8% with a used filter in place. The interventions also had significant effects on some SBS symptoms and environmental perceptions. The present results indicate that increasing outdoor air supply rate and replacing filters can have positive effects on health, comfort and performance. PRACTICAL IMPLICATIONS: Supply air filters should be changed frequently not just because their airflow resistance increases progressively but because they degrade air quality with negative consequences for health, comfort and the performance of office work, all of which are factors that affect office productivity (profitability). Increasing outdoor air supply rates may only be beneficial when new filters are installed. Unwanted negative effects may be produced when used filters are in place. Filter condition (used or new) should always be recorded to make it possible to draw sound conclusions in studies of the effects of outdoor air supply rates on building occupants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Cited by
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Wyon, D. P. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00278.x · Cited by 500
Self-citationTham, K. W. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.071 · Cited by 399
Zhang, X., Wargocki, P., Lian, Z., & Thyregod, C. (2017) · Indoor Air · doi:10.1111/ina.12284 · Cited by 360
Self-citationIndoor air pollutants in office environments: Assessment of comfort, health, and performance
Wolkoff, P. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.08.001 · Cited by 342
Metadata
- Authors
- Wargocki, P., Wyon, D. P., & Fanger, P. O.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2004-12
- Volume
- 14
- Issue
- s8
- Pages
- 7-16
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2136835326
- Cited by
- 136
- References
- 1
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.