Association between substandard classroom ventilation rates and students’ academic achievement
Open accessAbstract
UNLABELLED: This study focuses on the relationship between classroom ventilation rates and academic achievement. One hundred elementary schools of two school districts in the southwest United States were included in the study. Ventilation rates were estimated from fifth-grade classrooms (one per school) using CO(2) concentrations measured during occupied school days. In addition, standardized test scores and background data related to students in the classrooms studied were obtained from the districts. Of 100 classrooms, 87 had ventilation rates below recommended guidelines based on ASHRAE Standard 62 as of 2004. There is a linear association between classroom ventilation rates and students' academic achievement within the range of 0.9-7.1 l/s per person. For every unit (1 l/s per person) increase in the ventilation rate within that range, the proportion of students passing standardized test (i.e., scoring satisfactory or above) is expected to increase by 2.9% (95%CI 0.9-4.8%) for math and 2.7% (0.5-4.9%) for reading. The linear relationship observed may level off or change direction with higher ventilation rates, but given the limited number of observations, we were unable to test this hypothesis. A larger sample size is needed for estimating the effect of classroom ventilation rates higher than 7.1 l/s per person on academic achievement. PRACTICAL IMPLICATIONS: The results of this study suggest that increasing the ventilation rates toward recommended guideline ventilation rates in classrooms should translate into improved academic achievement of students. More studies are needed to fully understand the relationships between ventilation rate, other indoor environmental quality parameters, and their effects on students' health and achievement. Achieving the recommended guidelines and pursuing better understanding of the underlying relationships would ultimately support both sustainable and productive school environments for students and personnel.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
87% of classrooms in one hundred elementary schools in the southwest of the U.S. had air quality problems.
“Haverinen-Shaughnessy et al. [20] investigated one hundred elementary schools in the southwest of the U.S. and found that 87% of the classrooms had air quality problems.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [20]
The Introduction reports 100 elementary schools in the southwestern United States and says 87 of the 100 classrooms had ventilation rates below recommended guidelines. That supports a specific ventilation problem, but the broader description “air quality problems” is not established by the reported finding. (LLM, conf=0.85)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Socioeconomic Status and Academic Achievement: A Meta-Analytic Review of Research
Sirin, S. R. (2005) · Review of Educational Research · doi:10.3102/00346543075003417 · Cited by 4,687 · see citing works
Teachers, Schools, and Academic Achievement
Rivkin, S. G., Hanushek, E. A., & Kain, J. F. (2005) · Econometrica · doi:10.1111/j.1468-0262.2005.00584.x · Cited by 4,501 · see citing works
Konz, J. J., Lisi, K., Friebele, E., & Dixon, D. (1989) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 2,219 · see citing works
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034 · see citing works
Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information
Daisey, J. M., Angell, W. J., & Apte, M. G. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00153.x · Cited by 977 · see citing works
Heyneman, S. P., & Loxley, W. A. (1983) · American Journal of Sociology · doi:10.1086/227799 · Cited by 860 · see citing works
Fuligni, A. J. (1997) · Child Development · doi:10.1111/j.1467-8624.1997.tb01944.x · Cited by 698 · see citing works
Fisk, W. J. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.537 · Cited by 558 · see citing works
Koth, C. W., Bradshaw, C. P., & Leaf, P. J. (2008) · Journal of Educational Psychology · doi:10.1037/0022-0663.100.1.96 · Cited by 520 · see citing works
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462 · see citing works
Wargocki, P. L., & Wyon, D. P. (2007) · Science and Technology for the Built Environment · doi:10.1080/10789669.2007.10390951 · Cited by 366 · see citing works
Ventilation and performance in office work
Seppanen, O., Fisk, W. J., & Lei, Q. H. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00394.x · Cited by 303 · see citing works
Nye, B. A., Hedges, L. V., & Konstantopoulos, S. (2000) · American Educational Research Journal · doi:10.3102/00028312037001123 · Cited by 289 · see citing works
What Really Matters in Second Language Learning for Academic Achievement?
Saville‐Troike, M. (1984) · TESOL Quarterly · doi:10.2307/3586690 · Cited by 281 · see citing works
Explanation of Academic Achievement of Asian American Students
Peng, S. S., & Wright, D. (1994) · The Journal of Educational Research · doi:10.1080/00220671.1994.9941265 · Cited by 278 · see citing works
Shaughnessy, R. J., Haverinen-Shaughnessy, U., Nevalainen, A., & Moschandreas, D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00440.x · Cited by 230 · see citing works
Self-citationGeographic mobility and student achievement in an urban setting
Ingersoll, G. M., Scamman, J. P., & Eckerling, W. D. (1989) · Educational Evaluation and Policy Analysis · doi:10.3102/01623737011002143 · Cited by 220 · see citing works
New Ventilation Systems at Select Schools in Sweden—Effects on Asthma and Exposure
Smedje, G., & Norbäck, D. (2000) · Archives of Environmental Health An International Journal · doi:10.1080/00039890009603380 · Cited by 140 · see citing works
Tudor-Locke, C. E., Washington, T. L., Ainsworth, B. E., & Troiano, R. P. (2009) · Journal of Physical Activity and Health · doi:10.1123/jpah.6.3.347 · Cited by 138 · see citing works
Effects of Class Size and Instruction on Kindergarten Achievement
Milesi, C., & Gamoran, A. (2006) · Educational Evaluation and Policy Analysis · doi:10.3102/01623737028004287 · Cited by 94 · see citing works
Research Report on Effects of HVAC on Student Performance
Wyon, D. P., & Wargocki, P. L. (2006) · ASHRAE journal · Cited by 78 · see citing works
Indoor Air Quality and HVAC Systems
Bearg, D. W. (2019) · Routledge eBooks · doi:10.1201/9780203751152 · Cited by 72 · see citing works
Classroom Composition and Achievement Gains
Leiter, J. (1983) · Sociology of Education · doi:10.2307/2112381 · Cited by 44 · see citing works
A Study of Ventilation Measurement in an Office Building
Dols, W. S., & Persily, A. (1995) · doi:10.1520/stp14687s · Cited by 10 · see citing works
Schulte, R. J., Bridges, B. B., & Grimsrud, D. T. (2005) · ASHRAE journal · Cited by 5 · see citing works
(1997) · Interpreting International Journal of Research and Practice in Interpreting · doi:10.1075/intp.2.1-2.11ack · Cited by 1 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- [27]27. Shaughnessy, R., Haverinen-Shaughnessy, U., Nevalainen, A. and Moschandreas, D. (2007) Indoor environmental quality in schools and academic performance of students: studies from 2004 to present. In: Proceedings of ASHRAE IAQ Healthy and Sustainable Buildings, Baltimore, USA.
Cited by
Sorted by citations
Wargocki, P., & Wyon, D. P. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.020 · Cited by 290 · see citing works
Batterman, S. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14020145 · Cited by 271 · see citing works
Peng, Z., Deng, W., & Tenorio, R. (2017) · Sustainability · doi:10.3390/su9071180 · Cited by 101 · see citing works
“[20] investigated one hundred elementary schools in the southwest of the U.”
Background
- Authors
- Haverinen-Shaughnessy, U., Moschandreas, D. J., & Shaughnessy, R. J.
- Affiliations
- Illinois Institute of Technology (US)
- University of Tulsa (US)
- Corresponding author
- Shaughnessy, R. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2010-10-28
- Volume
- 21
- Issue
- 2
- Pages
- 121-131
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2162103866
- Cited by
- 311
- References
- 26
- Citations by year
- 2026: 22 · 2025: 19 · 2024: 24 · 2023: 21 · 2022: 28 · 2021: 30 · 2020: 28 · 2019: 23 · 2018: 15 · 2017: 20 · 2016: 16 · 2015: 19 · 2014: 17 · 2013: 16 · 2012: 10
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Indoor Air (publishedVersion)
- PubMed (publishedVersion)
- STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) (submittedVersion)
- Funders
- U.S. Environmental Protection Agency
- Academy of Finland
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Social Sciences › Education › Educational Environments and Student Outcomes
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- academic performance, CO2 concentration, elementary school classrooms, ASHRAE Standard 62.2, indoor air quality, standardized test scores, school indoor environment
- MeSH terms
- Carbon Dioxide, Educational Measurement, Educational Status, Humans, Mathematics, Reading, Schools, Students, Ventilation, Southwestern United States, Linear Models, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review