EEMCO guidance for the assessment of stratum corneum hydration: electrical methods
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Background/aims: The improvement of stratum corneum hydration is one of the most important claims in the cosmetic industry. Methods: Objective assessment of moisturization can be done with devices based on electrical methods provided these instruments are used in an appropriate manner. Results: This paper deals with the biophysical basis behind these techniques and describes the most important variables, pitfalls and drawbacks related to measurements and current instrumentation. Individual‐related and environment‐related variables are also analyzed as well as study designs for predictive or use tests. Conclusions: Practical suggestions for standardization of measurements are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of non-invasive methods and the skin
Guy, R. H. (1996) · Journal of Controlled Release · doi:10.1016/0168-3659(96)01365-x · Cited by 412
Bioengineering of the skin: Water and the stratum corneum
Edwards, D. A. (1995) · Journal of Controlled Release · doi:10.1016/0168-3659(95)90005-5 · Cited by 290
Friction, capacitance and transepidermal water loss (TEWL) in dry atopic and normal skin
LODEN, M., OLSSON, H., AXELL, T., & LINDE, Y. W. (1992) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1992.tb07810.x · Cited by 207
Non-invasive physiological measurements
Escourrou, P. (1988) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1988.95111 · Cited by 100
Hashimoto-Kumasaka, K., Takahashi, K., & Tagami, H. (1993) · Acta Dermato-Venereologica · doi:10.2340/0001555573335339 · Cited by 95
The influence of a single application of different moisturizers on the skin capacitance.
Lodén, M., & Lindberg, M. (1991) · Acta Dermato-Venereologica · doi:10.2340/00015555717982 · Cited by 78
Blichmann, C. W., Serup, J. V., & Winther, A. (1989) · PubMed · Cited by 68
Serup, J. (1992) · Acta Dermato-Venereologica · doi:10.2340/000155551773438 · Cited by 56
Serup, J., & Blichmann, C. (1987) · Acta Dermato-Venereologica · doi:10.2340/0001555567357359 · Cited by 46
Cited by
Natural skin surface pH is on average below 5, which is beneficial for its resident flora
Lambers, H., Piessens, S., Bloem, A., Pronk, H., & Finkel, P. (2006) · International Journal of Cosmetic Science · doi:10.1111/j.1467-2494.2006.00344.x · Cited by 909
EEMCO Guidance for the Assessment of Transepidermal Water Loss in Cosmetic Sciences
Rogiers, V. (2001) · Skin Pharmacology and Physiology · doi:10.1159/000056341 · Cited by 525
Chamlin, S. (2002) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(02)00048-8 · Cited by 449
Nikolovski, J., Stamatas, G. N., Kollias, N., & Wiegand, B. C. (2008) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5701239 · Cited by 388
“Instrumentation Skin conductance was measured to evaluate the hydration state of the SC using the NOVA DPM (NOVA, Portsmouth, NH), which measures an electrical parameter directly relevant to hydration of the upper SC layers (Berardesca, 1997).”
MethodFlexible graphene photodetectors for wearable fitness monitoring
Polat, E. O., Mercier, G., Nikitskiy, I., Puma, E., Galan, T., Gupta, S., Montagut, M., Piqueras, J. J., Bouwens, M., Durduran, T., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw7846 · Cited by 298
Plessis, J. D., Stefaniak, A., Eloff, F., John, S., Agner, T., Chou, T., Nixon, R., Steiner, M., Franken, A., Kudla, I., et al. (2013) · Skin Research and Technology · doi:10.1111/srt.12037 · Cited by 231
“Sweating from thermal, emotional, and physical mechanisms increases TEWL and skin hydration values (62, 63), but can be controlled by allowing for adequate acclimatization of subjects to the measurement environment and performing measurements under specific conditions of ambient temperature and humidity (7, 27, 28).”
BackgroundCrowther, J. M., Sieg, A., Blenkiron, P., Marcott, C., Matts, P. J., Kaczvinsky, J. R., & Rawlings, A. V. (2008) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2008.08703.x · Cited by 224
Heinrich, U., Koop, U., Leneveu‐Duchemin, M. ‐., Osterrieder, K., Bielfeldt, S., Chkarnat, C., Degwert, J., Häntschel, D., Jaspers, S., Nissen, H. ‐., et al. (2003) · International Journal of Cosmetic Science · doi:10.1046/j.1467-2494.2003.00172.x · Cited by 224
A Wearable Hydration Sensor with Conformal Nanowire Electrodes
Yao, S., Myers, A., Malhotra, A., Lin, F., Bozkurt, A., Muth, J. F., & Zhu, Y. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601159 · Cited by 213
Stamatas, G. N., Nikolovski, J., Mack, M. C., & Kollias, N. (2011) · International Journal of Cosmetic Science · doi:10.1111/j.1468-2494.2010.00611.x · Cited by 202
Dal'Belo, S. E., Rigo Gaspar, L., & Berardo Gonçalves Maia Campos, P. M. (2006) · Skin Research and Technology · doi:10.1111/j.0909-752x.2006.00155.x · Cited by 192
“All measurements were carried out according to the relevant guidelines (15, 16).”
MethodChanges in Diapered and Nondiapered Infant Skin Over the First Month of Life
Visscher, M. O., Chatterjee, R., Munson, K. A., Pickens, W. L., & Hoath, S. B. (2000) · Pediatric Dermatology · doi:10.1046/j.1525-1470.2000.01711.x · Cited by 181
“An increasing slope is indicative of water buildup behind the probe head (23).”
BackgroundThe revised EEMCO guidance for the in vivo measurement of water in the skin
Berardesca, E., Loden, M., Serup, J., Masson, P., & Rodrigues, L. M. (2018) · Skin Research and Technology · doi:10.1111/srt.12599 · Cited by 165
Self-citationGlycerol Accelerates Recovery of Barrier Function In Vivo
Fluhr, J. W., Gloor, M., Lehmann, L., Lazzerini, S., Distante, F., & Berardesca, E. (1999) · Acta Dermato-Venereologica · doi:10.1080/000155599750009825 · Cited by 164
“The measurements were performed according to the valid guidelines (8, 9).”
MethodSelf-citationBuonocore, D., Nobile, Cestone, Santin, Bottone, Marzatico, Lazzeretti, & Tocabens (2012) · Clinical Cosmetic and Investigational Dermatology · doi:10.2147/ccid.s36102 · Cited by 57
Nagata, C., Nakamura, K., Wada, K., Oba, S., Hayashi, M., Takeda, N., & Yasuda, K. (2010) · British Journal Of Nutrition · doi:10.1017/s0007114509993461 · Cited by 53
Skin hydration in postmenopausal women: argan oil benefit with oral and/or topical use
Boucetta, K. Q., Charrouf, Z., Derouiche, A., Rahali, Y., & Bensouda, Y. (2014) · Menopausal Review · doi:10.5114/pm.2014.46470 · Cited by 31
“The measurements were performed according to the EEMCO guidance for assessment of stratum corneum hydration [16].”
MethodHuygen, L., Thys, P. M., Wollenberg, A., Gutermuth, J., & Krohn, I. K. (2024) · Annals of Dermatology · doi:10.5021/ad.23.052 · Cited by 23
Metadata
- Authors
- Berardesca, E., & European Group for Efficacy Measurements on Cosmetics and Other Topical Products (EEMCO)
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 1997-05
- Volume
- 3
- Issue
- 2
- Pages
- 126-132
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2023777632
- Cited by
- 493
- References
- 13
- FWCI
- 12.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.