CoChat

Measurement of hydration in the stratum corneum with the MoistureMeter and comparison with the Corneometer

Open access
Alanen, Esko, Nuutinen, Jouni, Nicklén, Kirsi, Lahtinen, Tapani, Mönkkönen, Jukka · 2004 · Skin Research and Technology
Cited by 136

The DOI matches its Crossref record.

Abstract

Background/purpose: MoistureMeter is a novel capacitive device for measuring the hydration of stratum corneum (SC). The capacitor ‘plates’ are formed by the probe material and the well‐conducting epidermal–dermal skin layers, while the dry layer of SC acts as an ‘insulator’ of the capacitor. Due to this measurement principle, the measurement depth is not constant, but equal to the thickness of the dry layer of SC. The present study was undertaken to test the MoistureMeter SC‐2 in an experimental setup simulating the uppermost skin structure. The sensitivity of the MoistureMeter was compared with a conventional device Corneometer CM 820 in eight healthy volunteers. Methods: The experimental setup consisted of a polyethene foil simulating SC and a mixture of cellulose and saline simulating the underlying skin layers with a high water content. The hydration of SC of volar forearm was measured in eight healthy volunteers both with the MoistureMeter SC‐2 and Corneometer CM 820 after the application of three different skin formulations: base, base plus salt (2 wt% NaCl), base plus salt and glycerin (5 wt%). In the sorption–desorption test, the skin was wetted with a drop of water and the dehydration was followed with both devices for 2 min. Results: The test with the experimental setup agreed with the results predicted by the mathematical capacitance model. The hydration values of the MoistureMeter SC‐2 and Corneometer CM 820 correlated well (R=0.75), but the relative range of readings with the MoistureMeter was approximately three times larger than with Corneometer. The MoistureMeter was insensitive for the salt (2 wt% NaCl) of the formulation and differentiated the hydration effect of glycerin better than the Corneometer. In the sorption–desorption test, the MoistureMeter demonstrated the individual differences between the volunteers, whereas with the Corneometer the differences were minimal. Conclusion: The capacitive measuring principle of the MoistureMeter was demonstrated in an experimental arrangement. Although both instruments yielded equivalent data with the base formulation, the MoistureMeter was a more sensitive device than the Corneometer CM 820 and independent of added salt in the formulations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0846.2004.00050.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 136

Metadata

Authors
Alanen, E., Nuutinen, J., Nicklén, K., Lahtinen, T., & Mönkkönen, J.
Venue
Skin Research and Technology
Publisher
Wiley
Published
2004-01-20
Volume
10
Issue
1
Pages
32-37
ISSN
  • 0909-752X (ISSN-L)
  • 1600-0846
OpenAlex
W1982449752
Cited by
136
References
0
FWCI
0.71
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of hydration in the stratum corneum with the MoistureMeter and comparison with the Corneometer. https://app.cochat.ai/papers/10.1111/j.1600-0846.2004.00050.x
The paper
Alanen, E., Nuutinen, J., Nicklén, K., Lahtinen, T., & Mönkkönen, J. (2004). Measurement of hydration in the stratum corneum with the MoistureMeter and comparison with the Corneometer. Skin Research and Technology. https://doi.org/10.1111/j.1600-0846.2004.00050.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.