Automatic lesion boundary detection in dermoscopy images using gradient vector flow snakes
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Background: Malignant melanoma has a good prognosis if treated early. Dermoscopy images of pigmented lesions are most commonly taken at × 10 magnification under lighting at a low angle of incidence while the skin is immersed in oil under a glass plate. Accurate skin lesion segmentation from the background skin is important because some of the features anticipated to be used for diagnosis deal with shape of the lesion and others deal with the color of the lesion compared with the color of the surrounding skin. Methods: In this research, gradient vector flow (GVF) snakes are investigated to find the border of skin lesions in dermoscopy images. An automatic initialization method is introduced to make the skin lesion border determination process fully automated. Results: Skin lesion segmentation results are presented for 70 benign and 30 melanoma skin lesion images for the GVF‐based method and a color histogram analysis technique. The average errors obtained by the GVF‐based method are lower for both the benign and melanoma image sets than for the color histogram analysis technique based on comparison with manually segmented lesions determined by a dermatologist. Conclusions: The experimental results for the GVF‐based method demonstrate promise as an automated technique for skin lesion segmentation in dermoscopy images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398 · cited 1×
“The blurred image is inverted and thresholded using the Otsu technique (22), a histogram-based approach that assumes Gaussian distributions for the background and foreground pixels, where a threshold T is the gray level that maximizes between-group variance.”
MethodKass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070 · cited 2×
“The concept of deformable active contours, or snakes, was introduced by Kass et al. (12).”
BackgroundMethods of Theoretical Physics
Morse, P. M., Feshbach, H., & Hill, E. L. (1954) · American Journal of Physics · doi:10.1119/1.1933765 · Cited by 13,197
de Boor, C. (1978) · Applied Mathematical Sciences · doi:10.1007/978-1-4612-6333-3 · Cited by 11,944 · cited 1×
“Linear interpolation (25) was used to add snake points during deformation if the Euclidean distance between two neighboring snake points became greater than one pixel.”
MethodMethods of theoretical physics
Domenicali, C. A. (1954) · Journal of the Franklin Institute · doi:10.1016/0016-0032(54)90634-1 · Cited by 4,838
Snakes, shapes, and gradient vector flow
Xu, C., & Prince, J. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661186 · Cited by 4,001 · cited 8×
“GVF fields are computed through a diffusion process (13), similar in spirit to the distance potential forces of Cohen and Cohen (14).”
BackgroundMethodInfluentialHaralock, R. M., & Shapiro, L. G. (1991) · Addison-Wesley Longman Publishing Co., Inc. eBooks · Cited by 3,933
Finite-element methods for active contour models and balloons for 2-D and 3-D images
Cohen, L. D., & Cohen, I. (1993) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.244675 · Cited by 1,378 · cited 2×
“Conventional snakes lack the larger capture range of several new methods (13, 14).”
BackgroundMethodA Fast algorithm for active contours and curvature estimation
Williams, D. J., & Shah, M. (1992) · CVGIP: Image Understanding · doi:10.1016/1049-9660(92)90003-l · Cited by 1,101 · cited 1×
“See (13, 18) for a more detailed mathematical description of GVF snakes.”
BackgroundNachbar, F., Stolz, W., Merkle, T., Cognetta, A. B., Vogt, T., Landthaler, M., Bilek, P., Braun-Falco, O., & Plewig, G. (1994) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(94)70061-3 · Cited by 882
Pehamberger, H., Steiner, A., & Wolff, K. (1987) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(87)70239-4 · Cited by 634
Camera Models and Machine Perception
Sobel, I. E. (1970) · Cited by 498
Binder, M. (1995) · Archives of Dermatology · doi:10.1001/archderm.1995.01690150050011 · Cited by 354
In Vivo Epiluminescence Microscopy: Improvement of Early Diagnosis of Melanoma
Pehamberger, H., Binder, M., Steiner, A., & Wolff, K. (1993) · Journal of Investigative Dermatology · doi:10.1038/jid.1993.63 · Cited by 344
Steiner, A., Pehamberger, H., & Wolff, K. (1987) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(87)70240-0 · Cited by 292
Image Segmentation Using Deformable Models
Xu, C., Pham, D., & Prince, J. (2010) · Handbook of Medical Imaging, Volume 2. Medical Image Processing and Analysis · doi:10.1117/3.831079.ch3 · Cited by 264
An active contour model for mapping the cortex
Davatzikos, C. A., & Prince, J. L. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370403 · Cited by 244 · cited 1×
“The third weakness of traditional snakes is the difficulty with expanding into boundary concavities (15, 16).”
BackgroundPigmented Spitz nevi: Improvement of the diagnostic accuracy by epiluminescence microscopy
Steiner, A., Pehamberger, H., Binder, M., & Wolff, K. S. (1992) · Journal of the American Academy of Dermatology · doi:10.1016/0190-9622(92)70240-g · Cited by 116 · cited 1×
“Dermoscopy using various rule-or feature-based schemes improves pigmented lesion diagnostic accuracy over the accuracy obtained without this aid for those dermatologists trained in the technique (3–8).”
BackgroundA class of constrained clustering algorithms for object boundary extraction
Abrantes, A. J., & Marques, J. S. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.541421 · Cited by 112 · cited 1×
“The third weakness of traditional snakes is the difficulty with expanding into boundary concavities (15, 16).”
BackgroundIn Vivo Epiluminescence Microscopy: Improvement of Early Diagnosis of Melanoma.
Pehamberger, H., Binder, M., Steiner, A., & Wolff, K. (1993) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12470285 · Cited by 74
Dermatoscopy: usefulness in the differential diagnosis of cutaneous pigmentary lesions
Cristofolini, M., Zumiani, G., Bauer, P., Cristofolini, P., Boi, S., & Micciolo, R. (1994) · Melanoma Research · doi:10.1097/00008390-199412000-00008 · Cited by 67
Improvement of the diagnostic accuracy in pigmented skin lesions by epiluminescent light microscopy.
Steiner, A., Pehamberger, H., & Wolff, K. (1987) · PubMed · Cited by 35
Saphier, J. (1921) · Archives of Dermatological Research · doi:10.1007/bf01991493 · Cited by 30
Cited by
Skin Lesion Analysis towards Melanoma Detection Using Deep Learning Network
Li, Y., & Shen, L. (2018) · Sensors · doi:10.3390/s18020556 · Cited by 634
Skin lesion segmentation in dermoscopy images via deep full resolution convolutional networks
Al-masni, M. A., Al-antari, M. A., Choi, M.-T., Han, S.-M., & Kim, T.-S. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.05.027 · Cited by 483
Lesion border detection in dermoscopy images
Celebi, M. E., Iyatomi, H., Schaefer, G., & Stoecker, W. V. (2009) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2008.11.002 · Cited by 422
Self-citationComparison of Segmentation Methods for Melanoma Diagnosis in Dermoscopy Images
Silveira, M., Nascimento, J. C., Marques, J. S., Marcal, A. R. S., Mendonca, T., Yamauchi, S., Maeda, J., & Rozeira, J. (2009) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2008.2011119 · Cited by 409
Border detection in dermoscopy images using statistical region merging
Emre Celebi, M., Kingravi, H. A., Iyatomi, H., Alp Aslandogan, Y., Stoecker, W. V., Moss, R. H., Malters, J. M., Grichnik, J. M., Marghoob, A. A., Rabinovitz, H. S., et al. (2008) · Skin Research and Technology · doi:10.1111/j.1600-0846.2008.00301.x · Cited by 366
Self-citation
Metadata
- Authors
- Erkol, B., Moss, R. H., Joe Stanley, R., Stoecker, W. V., & Hvatum, E.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2005-02
- Volume
- 11
- Issue
- 1
- Pages
- 17-26
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2028140761
- Cited by
- 233
- References
- 23
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.