Dynamic indentation on human skin in vivo: ageing effects
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background/purpose: Knowledge of the mechanical properties of the human skin is very important for cosmetic and clinical research. Objective and quantitative measurements are essential to compare studies performed by different experimenters in different centres. The aim of this paper is to present a method to measure the viscoelastic properties of human skin in vivo using dynamic indentation. Methods: A complete device to assess the stiffness and damping of skin has been developed. The frequency and strain amplitude range from 10 to 60 Hz and from 1 to 10 μm. Tests on pure elastic inert materials have been performed to validate the device. An in vivo study including dynamic indentation, suction test, hydration measurement and topographic analysis has been performed on 46 subjects aged from 18 to 70 years, divided into three groups. Results: Results on inert materials show the validity of the device developed. The mechanical behaviour of the skin can be described by a Kelvin–Voight model under dynamic indentation. A comparison with a suction test, hydration and topographic measurements shows that the stiffness and the damping measured by dynamic indentation correspond mainly to the natural tense state of the skin on the body due to the dermis. A weak correlation has been found between dynamic indentation and suction parameters. The complex modulus measured by dynamic indentation at 10 Hz frequency stress ranges from 7.2 ± 2.1 kPa for the oldest group to 10.7 ± 2.6 kPa for the youngest group. Conclusion: The device presented gives convincing results. The measurement of stiffness and damping complements the viscoelastic phenomenological parameters of the suction test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Mechanical Analysis: A Practical Introduction
Menard, K. P. (1997) · Cited by 1,219
Mechanical properties and Young's modulus of human skin in vivo
Agache, P. G., Monneur, C., Leveque, J. L., & De Rigal, J. (1980) · Archives of Dermatological Research · doi:10.1007/bf00406415 · Cited by 741 · cited 3×
“The complex modulus [Eqs (10)–(12)] has a real part that is independent of the stress frequency, and an imaginary part that is dependent on the stress frequency.”
MethodDynamic Mechanical Analysis: A Practical Introduction
Menard, K. (1999) · CRC Press eBooks · doi:10.1201/9781420049183 · Cited by 618 · cited 1×
“Although dynamic mechanical analysis (15) using indentation is often used on polymer materials (16, 17), no application on human skin has been realized.”
MethodIn vivo model of the mechanical properties of the human skin under suction
Diridollou, S., Patat, F., Gens, F., Vaillant, L., Black, D., Lagarde, J. M., Gall, Y., & Berson, M. (2000) · Skin Research and Technology · doi:10.1034/j.1600-0846.2000.006004214.x · Cited by 350
Characterization of Viscoelastic Properties of Polymeric Materials Through Nanoindentation
Odegard, G. M., Gates, T. S., & Herring, H. M. (2005) · Experimental Mechanics · doi:10.1007/bf02428185 · Cited by 250 · cited 1×
“The stiffness and the damping are given by the following equations (18):”
BackgroundDelalleau, A., Josse, G., Lagarde, J.-M., Zahouani, H., & Bergheau, J.-M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.001 · Cited by 230 · cited 1×
“(4)], detection is performed at a low frequency (15 Hz) to maximize the difference with the phasingout without contact.”
BackgroundSelf-citationSkin ageing: changes of physical properties of human skin in vivo
Diridollou, S., Vabre, V., Berson, M., Vaillant, L., Black, D., Lagarde, J. M., Grégoire, J. M., Gall, Y., & Patat, F. (2001) · International Journal of Cosmetic Science · doi:10.1046/j.0412-5463.2001.00105.x · Cited by 178 · cited 1×
“The results found are also coherent, because the skin is less tense (lowering of the complex modulus measured by dynamic indentation) and stiffer (increase of the modulus measured by a suction test) with age (26).”
BackgroundIndentometric analysis of in vivo skin and comparison with artificial skin models
Jachowicz, J., McMullen, R. L., & Prettypaul, D. (2007) · Skin Research and Technology · doi:10.1111/j.1600-0846.2007.00229.x · Cited by 156 · cited 2×
“(3) found a Hertz modulus on 28–65-year-old women’s forearms in the range of 7–22 kPa with an indentation force of 0.”
BackgroundMethodAgache, P. G., & Humbert, P. G. (2004) · Springer eBooks · doi:10.1007/978-3-662-08585-1 · Cited by 148
Christensen, M. S., Hargens, C. W., Nacht, S., & Gans, E. H. (1977) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12507500 · Cited by 143 · cited 1×
“Dynamic studies using a torsion device (13) or tangential stress (14) have already been carried out.”
MethodHumbert, P. G., Maibach, H. I., Fanian, F., & Agache, P. G. (2011) · Medical Entomology and Zoology · Cited by 139
The Influence of Ageing on the in vivo Elasticity of Human Skin
Grahame, R., & Holt, P. J. L. (1969) · Gerontology · doi:10.1159/000211681 · Cited by 135
Analysis of adhesive behaviour of human skin in vivo by an indentation test
Pailler-Mattei, C., & Zahouani, H. (2005) · Tribology International · doi:10.1016/j.triboint.2004.11.003 · Cited by 112 · cited 3×
“Dynamic indentation on human skin in vivo: ageing effects G. Boyer1,2, L. Laquièze1, A. Le Bot1, S. Laquièze2 and H. Zahouani1 1Laboratory of Tribology and System Dynamics, UMR CNRS 5513, ENISE-ECL, Ecully, France and 2Laboratory PERITESCO, Paris, France Background/purpose: Knowledge of the mechanical properties of…”
BackgroundInfluentialSelf-citationStudy of adhesion forces and mechanical properties of human skin in vivo
Pailler-Mattéi, C., & Zahouani, H. (2004) · Journal of Adhesion Science and Technology · doi:10.1163/1568561042708368 · Cited by 87 · cited 1×
“This shape minimizes the adhesive effect of the skin (20), because the contact radius is constant with the indenter penetration.”
BackgroundSelf-citationVariations with age in the mechanical properties of human skin in vivo
Alexander, H., & Cook, T. H. (2006) · Journal of Tissue Viability · doi:10.1016/s0965-206x(06)63002-7 · Cited by 80
THE TIME-DEPENDENT MECHANICAL PROPERTIES OF SKIN
Barbenel, J. C., & Evans, J. H. (1977) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12507759 · Cited by 73 · cited 1×
“Dynamic studies using a torsion device (13) or tangential stress (14) have already been carried out.”
Method
Cited by
The relationship between skin function, barrier properties, and body‐dependent factors
Dąbrowska, A. K., Spano, F., Derler, S., Adlhart, C., Spencer, N. D., & Rossi, R. M. (2018) · Skin Research and Technology · doi:10.1111/srt.12424 · Cited by 496
Derler, S., & Gerhardt, L.-C. (2012) · Tribology Letters · doi:10.1007/s11249-011-9854-y · Cited by 425
Age-dependent biomechanical properties of the skin
Pawlaczyk, M., Lelonkiewicz, M., & Wieczorowski, M. (2013) · Advances in Dermatology and Allergology · doi:10.5114/pdia.2013.38359 · Cited by 335
Strain rate and anisotropy effects on the tensile failure characteristics of human skin
Ottenio, M., Tran, D., Ní Annaidh, A., Gilchrist, M. D., & Bruyère, K. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.10.006 · Cited by 220
Mechanical properties of human skin in vivo: a comparative evaluation in 300 men and women
Luebberding, S., Krueger, N., & Kerscher, M. (2014) · Skin Research and Technology · doi:10.1111/srt.12094 · Cited by 198
Metadata
- Authors
- Boyer, G., Laquièze, L., Le Bot, A., Laquièze, S., & Zahouani, H.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2009-01-15
- Volume
- 15
- Issue
- 1
- Pages
- 55-67
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2033468829
- Cited by
- 195
- References
- 16
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.