The DOI matches its Crossref record.
In vivo model of the mechanical properties of the human skin under suction
Open accessAbstract
Background/aims: A new method for the in vivo characterization of the mechanical properties of skin has been developed. This comprises a suction chamber and an ultrasound device to measure both the vertical displacement of the skin's surface, and the skin's thickness. Methods: A mathematical model of the mechanical behaviour of a taught elastic membrane is used to obtain a set of parameters intrinsic to the skin, such as Young's modulus (E) and the initial stress (σ 0), which reflect the stiffness and the natural tension of the skin, respectively. We also calculated an index of non‐elasticity of the skin (unrestored energy ratio, UER), which takes into account the volume of tissue mobilized. It determines a ratio between the energy input to the skin and the energy it dissipates. These parameters were evaluated from the volar forearm of 10 normal male volunteers. Results: The results were: 129±88 kPa for E, 13.5±5 kPa for σ 0, and 0.42±0.04 for UER; with reproducibilities of 9.5%, 12.4% and 6.4%, respectively. Conclusions: This new suction device was found useful for the study of the behaviour of the skin, and the device may be used for the evaluation of certain skin diseases and their therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
In vivo measurements of the elastic mechanical properties of human skin by indentation tests
Pailler-Mattei, C., Bec, S., & Zahouani, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.011 · Cited by 724
Dagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., et al. (2015) · Nature Materials · doi:10.1038/nmat4289 · Cited by 513
A numerical‐experimental method to characterize the non‐linear mechanical behaviour of human skin
Hendriks, F. M., Brokken, D., Van Eemeren, J. T. W. M., Oomens, C. W. J., Baaijens, F. P. T., & Horsten, J. B. A. M. (2003) · Skin Research and Technology · doi:10.1034/j.1600-0846.2003.00019.x · Cited by 347
Metadata
- Authors
- Diridollou, S., Patat, F., Gens, F., Vaillant, L., Black, D., Lagarde, J. M., Gall, Y., & Berson, M.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2000-11
- Volume
- 6
- Issue
- 4
- Pages
- 214-221
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2160911470
- Cited by
- 350
- References
- 0
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo model of the mechanical properties of the human skin under suction. https://app.cochat.ai/papers/10.1034/j.1600-0846.2000.006004214.x
- The paper
- Diridollou, S., Patat, F., Gens, F., Vaillant, L., Black, D., Lagarde, J. M., Gall, Y., & Berson, M. (2000). In vivo model of the mechanical properties of the human skin under suction. Skin Research and Technology. https://doi.org/10.1034/j.1600-0846.2000.006004214.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.