The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Characterization of the mechanical properties of a dermal equivalent compared with human skin in vivo by indentation and static friction tests
Abstract
Background/aims: The study of changes in skin structure with age is becoming all the more important with the increase in life. The atrophy that occurs during aging is accompanied by more profound changes, with a loss of organization within the elastic collagen network and alterations in the basal elements. The aim of this study is to present a method to determine the mechanical properties of total human skin in vivo compared with dermal equivalents (DEs) using indentation and static friction tests. Methods: A new bio‐tribometer working at a low contact pressure for the characterization the mechanical properties of the skin has been developed. This device, based on indentation and static friction tests, also allows to characterize the skin in vivo and reconstructed DEs in a wide range of light contact forces, stress and strain. Results: This original bio‐tribometer shows the ability to assess the skin elasticity and friction force in a wide range of light normal load (0.5–2 g) and low contact pressure (0.5–2 kPa). The results obtained by this approach show identical values of the Young's modulus E* and the shear modulus G* of six DEs obtained from a 62‐year‐old subject (E*=8.5±1.74 kPa and G*=3.3±0.46 kPa) and in vivo total skin of 20 subjects aged 55 to 70 years (E*=8.3±2.1 kPa, G*=2.8±0.8 kpa).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delalleau, A., Josse, G., Lagarde, J.-M., Zahouani, H., & Bergheau, J.-M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.001 · Cited by 230
Self-citation
Cited by
Nanocomposite scaffolds for accelerating chronic wound healing by enhancing angiogenesis
Nosrati, H., Aramideh Khouy, R., Nosrati, A., Khodaei, M., Banitalebi-Dehkordi, M., Ashrafi-Dehkordi, K., Sanami, S., & Alizadeh, Z. (2021) · Journal of Nanobiotechnology · doi:10.1186/s12951-020-00755-7 · Cited by 720
Adeli, H., Khorasani, M. T., & Parvazinia, M. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2018.10.115 · Cited by 512
The use of skin models in drug development
Mathes, S. H., Ruffner, H., & Graf-Hausner, U. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.12.006 · Cited by 318
Various manufacturing methods and ideal properties of scaffolds for tissue engineering applications
Suamte, L., Tirkey, A., Barman, J., & Jayasekhar Babu, P. (2023) · Smart Materials in Manufacturing · doi:10.1016/j.smmf.2022.100011 · Cited by 259
Effect of ageing on tactile transduction processes
Decorps, J., Saumet, J. L., Sommer, P., Sigaudo-Roussel, D., & Fromy, B. (2014) · Ageing Research Reviews · doi:10.1016/j.arr.2013.12.003 · Cited by 83
Metadata
- Authors
- Zahouani, H., Pailler‐Mattei, C., Sohm, B., Vargiolu, R., Cenizo, V., & Debret, R.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2009-01-15
- Volume
- 15
- Issue
- 1
- Pages
- 68-76
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2061621727
- Cited by
- 209
- References
- 1
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of the mechanical properties of a dermal equivalent compared with human skin in vivo by indentation and static friction tests. https://app.cochat.ai/papers/10.1111/j.1600-0846.2008.00329.x
- The paper
- Zahouani, H., Pailler‐Mattei, C., Sohm, B., Vargiolu, R., Cenizo, V., & Debret, R. (2009). Characterization of the mechanical properties of a dermal equivalent compared with human skin in vivo by indentation and static friction tests. Skin Research and Technology. https://doi.org/10.1111/j.1600-0846.2008.00329.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.