Characterization of the mechanical properties of a dermal equivalent compared with human skin in vivo by indentation and static friction tests
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background/aims: The study of changes in skin structure with age is becoming all the more important with the increase in life. The atrophy that occurs during aging is accompanied by more profound changes, with a loss of organization within the elastic collagen network and alterations in the basal elements. The aim of this study is to present a method to determine the mechanical properties of total human skin in vivo compared with dermal equivalents (DEs) using indentation and static friction tests. Methods: A new bio‐tribometer working at a low contact pressure for the characterization the mechanical properties of the skin has been developed. This device, based on indentation and static friction tests, also allows to characterize the skin in vivo and reconstructed DEs in a wide range of light contact forces, stress and strain. Results: This original bio‐tribometer shows the ability to assess the skin elasticity and friction force in a wide range of light normal load (0.5–2 g) and low contact pressure (0.5–2 kPa). The results obtained by this approach show identical values of the Young's modulus E* and the shear modulus G* of six DEs obtained from a 62‐year‐old subject (E*=8.5±1.74 kPa and G*=3.3±0.46 kPa) and in vivo total skin of 20 subjects aged 55 to 70 years (E*=8.3±2.1 kPa, G*=2.8±0.8 kpa).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sneddon, I. N. (1965) · International Journal of Engineering Science · doi:10.1016/0020-7225(65)90019-4 · Cited by 4,346 · cited 1×
“For any axisymmetric indenter, the reduced elastic modulus is obtained from (16, 17):”
BackgroundMechanical properties and Young's modulus of human skin in vivo
Agache, P. G., Monneur, C., Leveque, J. L., & De Rigal, J. (1980) · Archives of Dermatological Research · doi:10.1007/bf00406415 · Cited by 741
In vivo measurements of the elastic mechanical properties of human skin by indentation tests
Pailler-Mattei, C., Bec, S., & Zahouani, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.011 · Cited by 724 · cited 1×
“(26) developped a mechanical model by considering two layers.”
BackgroundSelf-citationVickers Indentation Curves of Magnesium Oxide (MgO)
Loubet, J. L., Georges, J. M., Marchesini, O., & Meille, G. (1984) · Journal of Tribology · doi:10.1115/1.3260865 · Cited by 421 · cited 1×
“For any axisymmetric indenter, the reduced elastic modulus is obtained from (16, 17):”
BackgroundIn vivo model of the mechanical properties of the human skin under suction
Diridollou, S., Patat, F., Gens, F., Vaillant, L., Black, D., Lagarde, J. M., Gall, Y., & Berson, M. (2000) · Skin Research and Technology · doi:10.1034/j.1600-0846.2000.006004214.x · Cited by 350 · cited 2×
“The most commonly used methods are based on the measurement of suction, which consists in applying a negative pressure to the skin (1, 2), torsion (3, 4) and traction, by applying a linear displacement in the horizontal plane of the skin (5).”
BackgroundMethodA numerical‐experimental method to characterize the non‐linear mechanical behaviour of human skin
Hendriks, F. M., Brokken, D., Van Eemeren, J. T. W. M., Oomens, C. W. J., Baaijens, F. P. T., & Horsten, J. B. A. M. (2003) · Skin Research and Technology · doi:10.1034/j.1600-0846.2003.00019.x · Cited by 347 · cited 2×
“(2) The solicited layer depends on the geometry of the probe.”
BackgroundMethodDelalleau, A., Josse, G., Lagarde, J.-M., Zahouani, H., & Bergheau, J.-M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.001 · Cited by 230 · cited 1×
“(25) studied a coupling approach, based on the inverse method of the indentation test with a numerical simulation, modeled by finite elements using the SYSTUS software.”
MethodSelf-citationThe measurement and modelling of the mechanical properties of human skin in vivo—I. The measurement
Manschot, J. F. M., & Brakkee, A. J. M. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90124-7 · Cited by 170
Torsional elasticity of human skin in vivo
Sanders, R. (1973) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00591373 · Cited by 169 · cited 3×
“(3) All these methods are used to characterize the skin rheology by descriptive parameters in vivo.”
MethodIn vivo Biophysical Characterization of Skin Physiological Differences in Races
Berardesca, E., de Rigal, J., Leveque, J. L., & Maibach, H. I. (1991) · Dermatology · doi:10.1159/000247752 · Cited by 166 · cited 1×
“The most commonly used methods are based on the measurement of suction, which consists in applying a negative pressure to the skin (1, 2), torsion (3, 4) and traction, by applying a linear displacement in the horizontal plane of the skin (5).”
Method
Cited by
Characterization of the anisotropic mechanical properties of excised human skin
Ní Annaidh, A., Bruyère, K., Destrade, M., Gilchrist, M. D., & Otténio, M. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2011.08.016 · Cited by 763
Nanocomposite scaffolds for accelerating chronic wound healing by enhancing angiogenesis
Nosrati, H., Aramideh Khouy, R., Nosrati, A., Khodaei, M., Banitalebi-Dehkordi, M., Ashrafi-Dehkordi, K., Sanami, S., & Alizadeh, Z. (2021) · Journal of Nanobiotechnology · doi:10.1186/s12951-020-00755-7 · Cited by 720
Adeli, H., Khorasani, M. T., & Parvazinia, M. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2018.10.115 · Cited by 512
The relationship between skin function, barrier properties, and body‐dependent factors
Dąbrowska, A. K., Spano, F., Derler, S., Adlhart, C., Spencer, N. D., & Rossi, R. M. (2018) · Skin Research and Technology · doi:10.1111/srt.12424 · Cited by 496
Bioprinting: From Tissue and Organ Development to in Vitro Models
Mota, C., Camarero-Espinosa, S., Baker, M. B., Wieringa, P., & Moroni, L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00789 · Cited by 345
Age-dependent biomechanical properties of the skin
Pawlaczyk, M., Lelonkiewicz, M., & Wieczorowski, M. (2013) · Advances in Dermatology and Allergology · doi:10.5114/pdia.2013.38359 · Cited by 335
Morgado, P. I., Aguiar-Ricardo, A., & Correia, I. J. (2015) · Journal of Membrane Science · doi:10.1016/j.memsci.2015.04.064 · Cited by 323
The use of skin models in drug development
Mathes, S. H., Ruffner, H., & Graf-Hausner, U. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.12.006 · Cited by 318
Various manufacturing methods and ideal properties of scaffolds for tissue engineering applications
Suamte, L., Tirkey, A., Barman, J., & Jayasekhar Babu, P. (2023) · Smart Materials in Manufacturing · doi:10.1016/j.smmf.2022.100011 · Cited by 259
Chitosan based-asymmetric membranes for wound healing: A review
Miguel, S. P., Moreira, A. F., & Correia, I. J. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.01.072 · Cited by 259
Strain rate and anisotropy effects on the tensile failure characteristics of human skin
Ottenio, M., Tran, D., Ní Annaidh, A., Gilchrist, M. D., & Bruyère, K. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.10.006 · Cited by 220
Wearable Bioelectronics for Chronic Wound Management
Wang, C., Shirzaei Sani, E., & Gao, W. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202111022 · Cited by 208
Miguel, S., Ribeiro, M., Coutinho, P., & Correia, I. (2017) · Polymers · doi:10.3390/polym9050183 · Cited by 204
“This emphasizes the suitability of the produced membranes to confer adequate mechanical support during the tissue remodeling process, as well as, avoiding possible side effects resulting from the stress-shielding mechanism [60,64].”
BackgroundMaiti, R., Gerhardt, L.-C., Lee, Z. S., Byers, R. A., Woods, D., Sanz-Herrera, J. A., Franklin, S. E., Lewis, R., Matcher, S. J., & Carré, M. J. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.05.035 · Cited by 193
Engineering Bioactive Scaffolds for Skin Regeneration
Hosseini, M., & Shafiee, A. (2021) · Small · doi:10.1002/smll.202101384 · Cited by 177
Use of Silicone Materials to Simulate Tissue Biomechanics as Related to Deep Tissue Injury
Sparks, J. L., Vavalle, N. A., Kasting, K. E., Long, B., Tanaka, M. L., Sanger, P. A., Schnell, K., & Conner-Kerr, T. A. (2015) · Advances in Skin & Wound Care · doi:10.1097/01.asw.0000460127.47415.6e · Cited by 168
Effect of ageing on tactile transduction processes
Decorps, J., Saumet, J. L., Sommer, P., Sigaudo-Roussel, D., & Fromy, B. (2014) · Ageing Research Reviews · doi:10.1016/j.arr.2013.12.003 · Cited by 83
Evaluation of the efficacy of a dill extract in vitro and in vivo
Sohm, B., Cenizo, V., André, V., Zahouani, H., Pailler‐Mattei, C., & Vogelgesang, B. (2011) · International Journal of Cosmetic Science · doi:10.1111/j.1468-2494.2010.00606.x · Cited by 25
Self-citation
Metadata
- Authors
- Zahouani, H., Pailler‐Mattei, C., Sohm, B., Vargiolu, R., Cenizo, V., & Debret, R.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2009-01-15
- Volume
- 15
- Issue
- 1
- Pages
- 68-76
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2061621727
- Cited by
- 209
- References
- 24
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.