Histological correlates of optical coherence tomography in non‐melanoma skin cancer
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background: Non‐melanoma skin cancer (NMSC) is rarely fatal but is now the most common malignancy occurring in white populations, accounting for 70% of the cost of managing skin cancer. Optical coherence tomography (OCT) has the potential to improve diagnostic accuracy and help delineate pre‐surgical margins in NMSC. Its widespread clinical acceptance awaits the accumulation of evidence from studies of direct histological comparisons. Method: In this study, seventy‐eight subjects presenting with skin lesions, including 28 NMSCs, were imaged using the VivoSight® OCT scanner and a biopsy taken. Haemotoxylin and eosin stained histology sections were compared with the OCT images. Results: The depth of superficial basal cell carcinoma (BCC) lesions (<1 mm) can be measured accurately using OCT. A low‐strength OCT signal at the periphery of the cell nests seen in superficial and nodular BCC is identified as corresponding to cellular palisading. A weak inverse linear correlation (r2 = 0.3) is found between the optical attenuation coefficient measured on OCT and the nuclear‐cytoplasmic ratio (N/C) of cells determined from histology. Conclusions: OCT has clinical value in providing accurate dimensional measurement of superficial BCC and in identifying the presence of peripheral palisading in nodular BCC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456 · cited 1×
“The VivoSight uses a swept-source Fourier domain OCT design (31) with a centre wavelength k = 1305 ± 15 nm, which lies within the optical ‘window’ for tissue (32).”
MethodGuidelines for the management of basal cell carcinoma
Telfer, N. R., Colver, G. B., & Morton, C. A. (2008) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2008.08666.x · Cited by 960
Salomatina, E. V., Jiang, B., Novak, J., & Yaroslavsky, A. N. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2398928 · Cited by 599
Using optical coherence tomography to evaluate skin sun damage and precancer
Korde, V. R., Bonnema, G. T., Xu, W., Krishnamurthy, C., Ranger‐Moore, J., Saboda, K., Slayton, L. D., Salasche, S. J., Warneke, J. A., Alberts, D. S., et al. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20573 · Cited by 145 · cited 12×
“The mean (± 2 SD) difference between OCT and histology is –0.54 ± 1.14 mm. Figure 7 demonstrates a large bias towards underestimation of tumour depth in OCT for tumour margin depths > 1 mm. Confining the analysis to lesions of depth 1 mm, reduces the bias to –0.17 ± 0.3 mm. Lesions 1 mm in this analysis include all th…”
ResultInfluential
Cited by
Dubois, A., Levecq, O., Azimani, H., Siret, D., Barut, A., Suppa, M., del Marmol, V., Malvehy, J., Cinotti, E., Rubegni, P., et al. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.10.106007 · Cited by 269
Dynamic Optical Coherence Tomography in Dermatology
Ulrich, M., Themstrup, L., de Carvalho, N., Manfredi, M., Grana, C., Ciardo, S., Kästle, R., Holmes, J., Whitehead, R., Jemec, G. B. E., et al. (2016) · Dermatology · doi:10.1159/000444706 · Cited by 230
Ulrich, M., Braunmuehl, T., Kurzen, H., Dirschka, T., Kellner, C., Sattler, E., Berking, C., Welzel, J., & Reinhold, U. (2015) · British Journal of Dermatology · doi:10.1111/bjd.13853 · Cited by 160
Line-Field Confocal Optical Coherence Tomography (LC-OCT) for Skin Imaging in Dermatology
Latriglia, F., Ogien, J., Tavernier, C., Fischman, S., Suppa, M., Perrot, J.-L., & Dubois, A. (2023) · Life · doi:10.3390/life13122268 · Cited by 74
Cheng, H. M., & Guitera, P. (2015) · British Journal of Dermatology · doi:10.1111/bjd.14042 · Cited by 65
Metadata
- Authors
- Coleman, A. J., Richardson, T. J., Orchard, G., Uddin, A., Choi, M. J., & Lacy, K. E.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2012-06-28
- Volume
- 19
- Issue
- 1
- Pages
- 10-9
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W1973559100
- Cited by
- 81
- References
- 4
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Histological correlates of optical coherence tomography in non‐melanoma skin cancer. https://app.cochat.ai/papers/10.1111/j.1600-0846.2012.00626.x
- The paper
- Coleman, A. J., Richardson, T. J., Orchard, G., Uddin, A., Choi, M. J., & Lacy, K. E. (2013). Histological correlates of optical coherence tomography in non‐melanoma skin cancer. Skin Research and Technology. https://doi.org/10.1111/j.1600-0846.2012.00626.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.