Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 192

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Periimplant Soft Tissue Barrier at Experimental One‐Piece Mini‐implants with Different Surface Topography in Humans: A Light‐Microscopic Overview and Histometric Analysis

Glauser, Roland, Schüpbach, Peter, Gottlow, Jan, Hämmerle, Christoph H. F. · 2005 · Clinical Implant Dentistry and Related Research

Abstract

Background: Following connection to the oral cavity, osseointegrated dental implants and surrounding tissues are exposed to microbiologic and biomechanical challenges. The establishment of a firm functional periimplant soft tissue barrier (PSTB) is considered to be important to protect the implant's interface from invasion of bacteria. The current knowledge on the histologic architecture of the PSTB is mainly based on animal experiments. Purpose: The aim of this study was to histologically characterize the PSTB formed in humans around experimental one‐piece mini‐implants with different surface topography. Materials and Methods: Five patients received a total of 12 experimental titanium, one‐piece mini‐implants with an oxidized (n = 4), an acid‐etched (n = 4), or a machined (n = 4) surface distal to therapeutic implants. Following transmucosal healing of 8 weeks and at abutment connection of the regular implants, the mini‐implants were harvested with a layer of surrounding hard and soft tissue. The specimens were fixed and processed for histologic sectioning according to standard procedures. The most central bucco‐oral section cut in the long axis was used for morphologic analyses of the PSTB. The vertical soft tissue morphology was quantified using histometric measurements. Results: The overall height of the soft tissue, that is, the biologic width, was around 4 to 4.5 mm and consisted of an epithelial and a supracrestal connective tissue barrier. The junctional epithelium established the attachment to the implant surface, whereas the collagen fibers and fibroblasts of the connective tissue seal were oriented parallel to the implant. The epithelial attachment was shorter at the oxidized and acid‐etched surfaces compared with the machined surfaces. Accordingly, the oxidized and acid‐etched mini‐implants exhibited a longer zone of connective tissue seal. Conclusion: The periimplant soft tissue formed at the experimental one‐piece mini‐implants in humans was of a character similar to that described in animal studies. The oxidized and acid‐etched implants revealed less epithelial downgrowth and longer connective tissue seal than machined implants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1708-8208.2005.tb00074.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 192

Metadata

Authors
Glauser, R., Schüpbach, P., Gottlow, J., & Hämmerle, C. H. F.
Venue
Clinical Implant Dentistry and Related Research
Publisher
Wiley
Published
2005-06
Volume
7
Issue
s1
Pages
S44-51
ISSN
  • 1523-0899 (ISSN-L)
  • 1708-8208
OpenAlex
W2038284316
Cited by
192
References
1
FWCI
13.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Periimplant Soft Tissue Barrier at Experimental One‐Piece Mini‐implants with Different Surface Topography in Humans: A Light‐Microscopic Overview and Histometric Analysis. https://app.cochat.ai/papers/10.1111/j.1708-8208.2005.tb00074.x
The paper
Glauser, R., Schüpbach, P., Gottlow, J., & Hämmerle, C. H. F. (2005). Periimplant Soft Tissue Barrier at Experimental One‐Piece Mini‐implants with Different Surface Topography in Humans: A Light‐Microscopic Overview and Histometric Analysis. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/j.1708-8208.2005.tb00074.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.