Periimplant Soft Tissue Barrier at Experimental One‐Piece Mini‐implants with Different Surface Topography in Humans: A Light‐Microscopic Overview and Histometric Analysis
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background: Following connection to the oral cavity, osseointegrated dental implants and surrounding tissues are exposed to microbiologic and biomechanical challenges. The establishment of a firm functional periimplant soft tissue barrier (PSTB) is considered to be important to protect the implant's interface from invasion of bacteria. The current knowledge on the histologic architecture of the PSTB is mainly based on animal experiments. Purpose: The aim of this study was to histologically characterize the PSTB formed in humans around experimental one‐piece mini‐implants with different surface topography. Materials and Methods: Five patients received a total of 12 experimental titanium, one‐piece mini‐implants with an oxidized (n = 4), an acid‐etched (n = 4), or a machined (n = 4) surface distal to therapeutic implants. Following transmucosal healing of 8 weeks and at abutment connection of the regular implants, the mini‐implants were harvested with a layer of surrounding hard and soft tissue. The specimens were fixed and processed for histologic sectioning according to standard procedures. The most central bucco‐oral section cut in the long axis was used for morphologic analyses of the PSTB. The vertical soft tissue morphology was quantified using histometric measurements. Results: The overall height of the soft tissue, that is, the biologic width, was around 4 to 4.5 mm and consisted of an epithelial and a supracrestal connective tissue barrier. The junctional epithelium established the attachment to the implant surface, whereas the collagen fibers and fibroblasts of the connective tissue seal were oriented parallel to the implant. The epithelial attachment was shorter at the oxidized and acid‐etched surfaces compared with the machined surfaces. Accordingly, the oxidized and acid‐etched mini‐implants exhibited a longer zone of connective tissue seal. Conclusion: The periimplant soft tissue formed at the experimental one‐piece mini‐implants in humans was of a character similar to that described in animal studies. The oxidized and acid‐etched implants revealed less epithelial downgrowth and longer connective tissue seal than machined implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donath, K., & Breuner, G. (1982) · Journal of Oral Pathology & Medicine · doi:10.1111/j.1600-0714.1982.tb00172.x · Cited by 1,636
Tissue-Integrated Prostheses. Osseointegration in Clinical Dentistry
Brånemark, P., Zarb, G. A., Albrektsson, T. O., & Rosen, H. M. (1986) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198603000-00037 · Cited by 1,556
Dimensions and Relations of the Dentogingival Junction in Humans
Gargiulo, A. W., Wentz, F. M., & Orban, B. (1961) · The Journal of Periodontology · doi:10.1902/jop.1961.32.3.261 · Cited by 1,053
The soft tissue barrier at implants and teeth
Berglundh, T., Lindhe, J., Ericsson, I., Marinello, C. P., Liljenberg, B., & Thornsen, P. (1991) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1991.020206.x · Cited by 901
Dimension of the periimplant mucosa: Biological width revisited
Berglundh, T., & Lindhe, J. (1996) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1996.tb00520.x · Cited by 798
Hermann, J. S., Cochran, D. L., Nummikoski, P. V., & Buser, D. (1997) · Journal of Periodontology · doi:10.1902/jop.1997.68.11.1117 · Cited by 678
The influence of abutment surface roughness on plaque accumulation and peri‐implant mucositis
Bollen, C. M. L., Papaioanno, W., Van Eldere, J., Schepers, E., Quirynen, M., & Van Steenberghe, D. (1996) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1996.070302.x · Cited by 661
Wennerberg, A., Albrektsson, T., Andersson, B., & Krol, J. J. (1995) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1995.060103.x · Cited by 537
Cochran, D. L., Hermann, J. S., Schenk, R. K., Higginbottom, F. L., & Buser, D. (1997) · Journal of Periodontology · doi:10.1902/jop.1997.68.2.186 · Cited by 504
Hermann, J. S., Cochran, D. L., Hermann, J. S., Buser, D., Schenk, R. K., & Schoolfield, J. D. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.120603.x · Cited by 468
The mucosal barrier following abutment dis/reconnection: An experimental study in dogs
Abrahamsson, I., Berglundh, T., & Lindhe, J. (1997) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1997.tb00230.x · Cited by 422
The mucosal attachment at different abutments: An experimental study in dogs
Abrahamsson, I., Berglundh, T., Glantz, P. ‐., & Lindhe, J. (1998) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1998.tb02513.x · Cited by 384
Soft Tissue Reactions to Non‐Submerged Unloaded Titanium Implants in Beagle Dogs
Buser, D., Weber, H. P., Donath, K., Fiorellini, J. P., Paquette, D. W., & Williams, R. C. (1992) · Journal of Periodontology · doi:10.1902/jop.1992.63.3.225 · Cited by 383
Biologic width around titanium implants. A physiologically formed and stable dimension over time
Hermann, J. S., Buser, D., Schenk, R. K., Higginbottom, F. L., & Cochran, D. L. (2000) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2000.011001001.x · Cited by 307
Removal torques for polished and rough titanium implants.
Carlsson, L. V., Röstlund, T., Albrektsson, B., & Albrektsson, T. O. (1988) · PubMed · Cited by 298
Abrahamsson, I., Zitzmann, N. U., Berglundh, T., Linder, E., Wennerberg, A., & Lindhe, J. (2002) · Journal of Clinical Periodontology · doi:10.1034/j.1600-051x.2002.290510.x · Cited by 194
Cited by
Soft tissue wound healing around teeth and dental implants
Sculean, A., Gruber, R., & Bosshardt, D. D. (2014) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12206 · Cited by 439
Rompen, E., Domken, O., Degidi, M., Farias Pontes, A. E., & Piattelli, A. (2006) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2006.01367.x · Cited by 356
Maló, P., de Araujo Nobre, M., & Lopes, I. (2008) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(08)60237-1 · Cited by 187
Guo, T., Gulati, K., Arora, H., Han, P., Fournier, B., & Ivanovski, S. (2021) · Dental Materials · doi:10.1016/j.dental.2021.02.005 · Cited by 180
Orchestrating soft tissue integration at the transmucosal region of titanium implants
Guo, T., Gulati, K., Arora, H., Han, P., Fournier, B., & Ivanovski, S. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.01.001 · Cited by 174
Metadata
- Authors
- Glauser, R., Schüpbach, P., Gottlow, J., & Hämmerle, C. H. F.
- Venue
- Clinical Implant Dentistry and Related Research
- Publisher
- Wiley
- Published
- 2005-06
- Volume
- 7
- Issue
- s1
- Pages
- S44-51
- ISSN
- 1523-0899 (ISSN-L)
- 1708-8208
- OpenAlex
- W2038284316
- Cited by
- 192
- References
- 16
- FWCI
- 13.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.