Zirconia in Fixed Implant Prosthodontics
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Background: CAD/CAM technology in combination with zirconia ceramic has increasingly gained popularity in implant dentistry. Purpose: This narrative review presents the current knowledge on zirconia utilized as framework material for implant‐borne restorations and implant abutments, laboratory tests and developments, clinical performance, and possible future trends for implant dentistry are addressed. Material and Methods: A review of available literature from 1990 through 2010 was conducted with search terms zirconia,”“implants,”“abutment,”“crown,” and “fixed dental prosthesis” using electronic databases (PubMed) and manual searching. Results: Latest applications of zirconia in implant dentistry include implant abutments, multiple unit and full‐arch frameworks as well as custom‐made bars to support fixed and removable prostheses. High biocompatibility, low bacterial surface adhesion as well as favorable chemical properties of zirconia ceramics are reported. Zirconia stabilized with yttrium oxide exhibits high flexural strength and fracture toughness due to a transformation toughening mechanism. Preliminary clinical data confirmed the high stability of zirconia for abutments and as a framework material for implant borne crowns and fixed dental prostheses. Zirconia abutment or framework damage has rarely been encountered. However, veneering porcelain fractures are the most common technical complication in implant‐supported zirconia restorations. These porcelain veneer failures have led to concerns regarding differences in coefficient of thermal expansions between core and veneering porcelain and their respective processing techniques. Conclusion: As presently evidence of clinical long‐term data is missing, caution with regard to especially extensive implant‐borne zirconia frameworks is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zirconia as a ceramic biomaterial
Piconi, C., & Maccauro, G. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00010-6 · Cited by 2,806
State of the art of zirconia for dental applications
Denry, I., & Kelly, J. R. (2008) · Dental Materials · doi:10.1016/j.dental.2007.05.007 · Cited by 2,133 · cited 1×
“In the early 1990s, zirconia was introduced to dentistry and has been made widely available through the computer-aided design/computer-aided manufacturing (CAD/CAM) technology.(1,3) The successful use of zirconia ceramics for the fabrication of tooth-supported restorations has encouraged clinicians to extend its appli…”
MethodAn overview of zirconia ceramics: Basic properties and clinical applications
Manicone, P. F., Rossi Iommetti, P., & Raffaelli, L. (2007) · Journal of Dentistry · doi:10.1016/j.jdent.2007.07.008 · Cited by 1,369 · cited 5×
“Because present clinical data is limited to 5-year observation periods, the relationship between aging of zirconia frameworks and long-term clinical performance need to be investigated in further evaluations.(12)”
BackgroundMethodInfluentialWhat future for zirconia as a biomaterial?
Chevalier, J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.034 · Cited by 1,228
Stabilized zirconia as a structural ceramic: An overview
Kelly, J. R., & Denry, I. (2008) · Dental Materials · doi:10.1016/j.dental.2007.05.005 · Cited by 1,172 · cited 1×
“This process initiates at surface grains, and then later progresses toward the bulk material causing a reduction in flexural strength of the material, putting it at risk of spontaneous catastrophic failure.(24,25) This problem mainly involves frameworks or parts of a framework that are not subjected to porcelain venee…”
BackgroundKosmač, T., Oblak, C., Jevnikar, P., Funduk, N., & Marion, L. (1999) · Dental Materials · doi:10.1016/s0109-5641(99)00070-6 · Cited by 818
Low-Temperature Degradation of Zirconia and Implications for Biomedical Implants
Chevalier, J., Gremillard, L., & Deville, S. (2007) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.37.052506.084250 · Cited by 741 · cited 1×
“In addition, concerns regarding the long-term stability of zirconia have led to controversial discussions regarding the utilization of zirconia as a substitute for alloys in implant dentistry.(10,11) Compendious information about the properties and outcome of zirconia-based implantsupported restorations would provide…”
BackgroundChristel, P., Meunier, A., Heller, M., Torre, J. P., & Peille, C. N. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230105 · Cited by 732
Phase change and mechanical properties of ZrO2-Y2O3 solid electrolyte after ageing
Kobayashi, K., KUWAJIMA, H., & Masaki, T. (1981) · Solid State Ionics · doi:10.1016/0167-2738(81)90138-7 · Cited by 661 · cited 1×
“A major drawback for zirconia restorations is the material inherent accelerated aging.(23) In a humid environment, spontaneous slow transformation from the tetragonal phase to the more stable monoclinic phase occurs in zirconia grains at relatively low temperatures of 150–400°C.”
BackgroundBacterial Adhesion on Commercially Pure Titanium and Zirconium Oxide Disks: An In Vivo Human Study
Scarano, A., Piattelli, M., Caputi, S., Favero, G. A., & Piattelli, A. (2004) · Journal of Periodontology · doi:10.1902/jop.2004.75.2.292 · Cited by 622
Cited by
Sailer, I., Strasding, M., Valente, N. A., Zwahlen, M., Liu, S., & Pjetursson, B. E. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13277 · Cited by 273
Zembic, A., Bösch, A., Jung, R. E., Hämmerle, C. H. F., & Sailer, I. (2013) · Clinical Oral Implants Research · doi:10.1111/clr.12044 · Cited by 183
Johansson, C., Kmet, G., Rivera, J., Larsson, C., & Vult Von Steyern, P. (2014) · Acta Odontologica Scandinavica · doi:10.3109/00016357.2013.822098 · Cited by 171
“The risk of complete fracture is minimal and only a few complete fractures have been registered in studies on tooth-supported zirconia-based restorations and none in studies on implant-supported ones [2,3].”
BackgroundWear and Corrosion Interactions on Titanium in Oral Environment: Literature Review
Souza, J. C. M., Henriques, M., Teughels, W., Ponthiaux, P., Celis, J.-P., & Rocha, L. A. (2015) · Journal of Bio- and Tribo-Corrosion · doi:10.1007/s40735-015-0013-0 · Cited by 171
“Abutments made of YTZP provide better results concerning esthetic for anterior restorations although data on longterm performance of fixed partial dentures on YTZP are still lacking [20, 21].”
BackgroundRevolution of Current Dental Zirconia: A Comprehensive Review
Alqutaibi, A. Y., Ghulam, O., Krsoum, M., Binmahmoud, S., Taher, H., Elmalky, W., & Zafar, M. S. (2022) · Molecules · doi:10.3390/molecules27051699 · Cited by 142
Metadata
- Authors
- Guess, P. C., Att, W., & Strub, J. R.
- Venue
- Clinical Implant Dentistry and Related Research
- Publisher
- Wiley
- Published
- 2010-12-22
- Volume
- 14
- Issue
- 5
- Pages
- 633-645
- ISSN
- 1523-0899 (ISSN-L)
- 1708-8208
- OpenAlex
- W2119588005
- Cited by
- 192
- References
- 38
- FWCI
- 11.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.