Zirconia in Fixed Implant Prosthodontics
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Background: CAD/CAM technology in combination with zirconia ceramic has increasingly gained popularity in implant dentistry. Purpose: This narrative review presents the current knowledge on zirconia utilized as framework material for implant‐borne restorations and implant abutments, laboratory tests and developments, clinical performance, and possible future trends for implant dentistry are addressed. Material and Methods: A review of available literature from 1990 through 2010 was conducted with search terms zirconia,”“implants,”“abutment,”“crown,” and “fixed dental prosthesis” using electronic databases (PubMed) and manual searching. Results: Latest applications of zirconia in implant dentistry include implant abutments, multiple unit and full‐arch frameworks as well as custom‐made bars to support fixed and removable prostheses. High biocompatibility, low bacterial surface adhesion as well as favorable chemical properties of zirconia ceramics are reported. Zirconia stabilized with yttrium oxide exhibits high flexural strength and fracture toughness due to a transformation toughening mechanism. Preliminary clinical data confirmed the high stability of zirconia for abutments and as a framework material for implant borne crowns and fixed dental prostheses. Zirconia abutment or framework damage has rarely been encountered. However, veneering porcelain fractures are the most common technical complication in implant‐supported zirconia restorations. These porcelain veneer failures have led to concerns regarding differences in coefficient of thermal expansions between core and veneering porcelain and their respective processing techniques. Conclusion: As presently evidence of clinical long‐term data is missing, caution with regard to especially extensive implant‐borne zirconia frameworks is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zirconia as a ceramic biomaterial
Piconi, C., & Maccauro, G. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00010-6 · Cited by 2,806
State of the art of zirconia for dental applications
Denry, I., & Kelly, J. R. (2008) · Dental Materials · doi:10.1016/j.dental.2007.05.007 · Cited by 2,133 · cited 1×
“In the early 1990s, zirconia was introduced to dentistry and has been made widely available through the computer-aided design/computer-aided manufacturing (CAD/CAM) technology.(1,3) The successful use of zirconia ceramics for the fabrication of tooth-supported restorations has encouraged clinicians to extend its appli…”
MethodAn overview of zirconia ceramics: Basic properties and clinical applications
Manicone, P. F., Rossi Iommetti, P., & Raffaelli, L. (2007) · Journal of Dentistry · doi:10.1016/j.jdent.2007.07.008 · Cited by 1,369 · cited 5×
“Because present clinical data is limited to 5-year observation periods, the relationship between aging of zirconia frameworks and long-term clinical performance need to be investigated in further evaluations.(12)”
BackgroundMethodInfluentialWhat future for zirconia as a biomaterial?
Chevalier, J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.034 · Cited by 1,228
Stabilized zirconia as a structural ceramic: An overview
Kelly, J. R., & Denry, I. (2008) · Dental Materials · doi:10.1016/j.dental.2007.05.005 · Cited by 1,172 · cited 1×
“This process initiates at surface grains, and then later progresses toward the bulk material causing a reduction in flexural strength of the material, putting it at risk of spontaneous catastrophic failure.(24,25) This problem mainly involves frameworks or parts of a framework that are not subjected to porcelain venee…”
BackgroundKosmač, T., Oblak, C., Jevnikar, P., Funduk, N., & Marion, L. (1999) · Dental Materials · doi:10.1016/s0109-5641(99)00070-6 · Cited by 818
Low-Temperature Degradation of Zirconia and Implications for Biomedical Implants
Chevalier, J., Gremillard, L., & Deville, S. (2007) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.37.052506.084250 · Cited by 741 · cited 1×
“In addition, concerns regarding the long-term stability of zirconia have led to controversial discussions regarding the utilization of zirconia as a substitute for alloys in implant dentistry.(10,11) Compendious information about the properties and outcome of zirconia-based implantsupported restorations would provide…”
BackgroundChristel, P., Meunier, A., Heller, M., Torre, J. P., & Peille, C. N. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230105 · Cited by 732
Phase change and mechanical properties of ZrO2-Y2O3 solid electrolyte after ageing
Kobayashi, K., KUWAJIMA, H., & Masaki, T. (1981) · Solid State Ionics · doi:10.1016/0167-2738(81)90138-7 · Cited by 661 · cited 1×
“A major drawback for zirconia restorations is the material inherent accelerated aging.(23) In a humid environment, spontaneous slow transformation from the tetragonal phase to the more stable monoclinic phase occurs in zirconia grains at relatively low temperatures of 150–400°C.”
BackgroundBacterial Adhesion on Commercially Pure Titanium and Zirconium Oxide Disks: An In Vivo Human Study
Scarano, A., Piattelli, M., Caputi, S., Favero, G. A., & Piattelli, A. (2004) · Journal of Periodontology · doi:10.1902/jop.2004.75.2.292 · Cited by 622
Swain, M. V. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.12.016 · Cited by 554
Bacterial colonization of zirconia ceramic surfaces: an in vitro and in vivo study.
Rimondini, L., Cerroni, L., Carrassi, A., & Torricelli, P. (2002) · PubMed · Cited by 511
Glauser, R., Sailer, I., Wohlwend, A., Studer, S., Schibli, M., & SCHARER, P. (2004) · PubMed · Cited by 395
Sailer, I., Philipp, A., Zembic, A., Pjetursson, B. E., Hämmerle, C. H. F., & Zwahlen, M. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01787.x · Cited by 368 · cited 1×
“A recent systematic review evaluating laboratory studies about the resistance of implant abutments with/without restorations identified nine studies evaluating zirconia abutments.(6) We additionally identified one further study (Table 1).”
BackgroundMarginal and internal fit of all‐ceramic CAD/CAM crown‐copings on chamfer preparations
BINDL, A., & MÖRMANN, W. H. (2005) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2005.01446.x · Cited by 363 · cited 1×
“Moreover, sandblasting has been reported to cause marginal defects and widen the gap between the crown and implant abutment.(62,63) However, sandblasting prior to cementation procedures is presently discussed with conflicting statements in the dental literature.”
BackgroundBeuer, F., Schweiger, J., Eichberger, M., Kappert, H. F., GERNET, W., & Edelhoff, D. (2008) · Dental Materials · doi:10.1016/j.dental.2008.04.019 · Cited by 334 · cited 1×
“To overcome chipping fractures of veneered zirconia restorations, a novel approach in veneering zirconia copings has been recently described.(65) Sintering a CAD/ CAM-milled lithium disilicate veneer cap onto the zirconia coping has significantly increased the mechanical strength of crown restorations and represents a…”
BackgroundDamage accumulation and fatigue life of particle-abraded ceramics.
Zhang, Y., Lawn, B. R., Malament, K. A., Thompson, V. P., & Rekow, E. D. (2006) · PubMed · Cited by 328
Zirconia in dentistry: Part 1. Discovering the nature of an upcoming bioceramic.
Vagkopoulou, T., Koutayas, S. O., Koidis, P. T., & Strub, J. R. (2009) · The European journal of esthetic dentistry · Cited by 317
Self-citationClinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results.
Tinschert, J., Schulze, K. A., Natt, G., Latzke, P. M., Heussen, N. M., & Spiekermann, H. (2008) · PubMed · Cited by 301
Degidi, M., Artese, L., Scarano, A., Perrotti, V., Gehrke, P., & Piattelli, A. (2006) · Journal of Periodontology · doi:10.1902/jop.2006.77.1.73 · Cited by 298
Zembic, A., Sailer, I., Jung, R. E., & Hämmerle, C. H. F. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01717.x · Cited by 263
Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs.
Molin, M., & Karlsson, S. L. (2008) · PubMed · Cited by 260
Akagawa, Y., Ichikawa, Y., Nikai, H., & Tsuru, H. (1993) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(93)90289-z · Cited by 246
Osseointegration and clinical success of zirconia dental implants: a systematic review.
Wenz, H. J., Bartsch, J., Wolfart, S., & Kern, M. (2008) · PubMed · Cited by 240
Zirconia Posts: A New All‐Ceramic Concept for Nonvital Abutment Teeth
MEYENBERG, K. H., LÜTHY, H., & SCHÄRER, P. (1995) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/j.1708-8240.1995.tb00565.x · Cited by 237
In vivo fracture resistance of implant-supported all-ceramic restorations
Yildirim, M., Fischer, H., Marx, R., & Edelhoff, D. (2003) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(03)00514-6 · Cited by 213
(2009) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(09)60140-2 · Cited by 199
Basic reactions of osteoblasts on structured material surfaces
Department of Cranio-Maxillofacial Surgery, U. O. M., Meyer, U., Büchter, A., Wiesmann, H., Joos, U., & Jones, D. (2005) · European Cells and Materials · doi:10.22203/ecm.v009a06 · Cited by 194 · cited 1×
“To determine the biocompatibility or interactions at the biomaterial–tissue interface, in vitro studies using cell cultures have been carried out.(44) It is well known today that ceramics, including zirconia, are highly biocompatible and are less prone to plaque accumulation than metal substrates.”
BackgroundHaraldson, T., Carlsson, G. E., & Ingervall, B. (1979) · Acta Odontologica Scandinavica · doi:10.3109/00016357909027582 · Cited by 194 · cited 1×
“Several studies reported a mean loading force of approximately 206 N and maximum biting forces of up to 290 N in the aesthetic zone.(48,49) In an in vitro study, unprepared titanium-reinforced zirconia and pure alumina abutments were compared for their outcome.”
BackgroundImpact of thermal misfit on shear strength of veneering ceramic/zirconia composites
Fischer, J., Stawarczyk, B., Trottmann, A., & Hämmerle, C. H. F. (2008) · Dental Materials · doi:10.1016/j.dental.2008.09.003 · Cited by 186
Biomechanical Compatibility and Design of Ceramic Implants for Orthopedic Surgery
CHRISTEL, P., MEUNIER, A., DORLOT, J. ‐., CROLET, J. ‐., WITVOET, J., SEDEL, L., & BOUTIN, P. (1988) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1988.tb38516.x · Cited by 168 · cited 1×
“In the early 1990s, zirconia was introduced to dentistry and has been made widely available through the computer-aided design/computer-aided manufacturing (CAD/CAM) technology.(1,3) The successful use of zirconia ceramics for the fabrication of tooth-supported restorations has encouraged clinicians to extend its appli…”
MethodFatigue and fracture properties of yttria partially stabilized zirconia crown systems
TSALOUCHOU, E., Cattell, M. J., Knowles, J. C., Pittayachawan, P., & McDonald, A. V. (2007) · Dental Materials · doi:10.1016/j.dental.2007.05.011 · Cited by 168 · cited 1×
“However, attempts to improve the microstructure and mechanical properties of veneering ceramics with development of glassceramic ingots for pressing veneering ceramics onto zirconia frameworks did not result in an increased reliability.(27,28) Cohesive veneer fractures have also been reported in pressed porcelain in c…”
BackgroundContemporary all-ceramic fixed partial dentures: a review
Raigrodski, A. J. (2004) · Dental Clinics of North America · doi:10.1016/j.cden.2003.12.008 · Cited by 130 · cited 1×
“There are two types of zirconia milling processes available: a) from pre-sintered blocks; and b) from densely sintered blocks.(22) Examples of pre-sintering systems are Cercon (Dentsply Friadent, Mannheim, Germany), LAVA (3 M ESPE, Seefeld, Germany), Procera (Nobel Biocare; Gothenburg, Sweden), Etkon (Straumann, Basel…”
BackgroundLarsson, C., von Steyern, P. V., Sunzel, B., & Nilner, K. (2006) · PubMed · Cited by 129
Customization of milled zirconia copings for all-ceramic crowns: A clinical report
Marchack, B. W., Futatsuki, Y., Marchack, C. B., & White, S. N. (2008) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(08)00028-0 · Cited by 121 · cited 2×
“An improved customized zirconia coping design that provides adequate support to the veneering porcelain has been derived from the conventional porcelain fused to metal technique.(33) A dual-scan procedure of the die and full-contour wax pattern has been merged to fabricate the desired framework.”
BackgroundMethodFracture-load values of all-ceramic cantilevered FPDs with different framework designs.
Ohlmann, B., Marienburg, K., Gabbert, O., Hassel, A. J., Gilde, H., & Rammelsberg, P. (2009) · PubMed · Cited by 40
Dunn, D. B. (2008) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(08)00149-2 · Cited by 32 · cited 1×
“With few case reports available, long-term clinical data about the survival rates of multiple screw-retained zirconia frameworks are currently lacking.(39,40) Despite limited scientific evidence, some manufacturers allow the fabrication of implant-supported, multi-unit, and full-arch restorations with screw-retained z…”
BackgroundChang, P. P., Henegbarth, E. A., & Lang, L. A. (2007) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(07)60020-1 · Cited by 23 · cited 1×
“With few case reports available, long-term clinical data about the survival rates of multiple screw-retained zirconia frameworks are currently lacking.(39,40) Despite limited scientific evidence, some manufacturers allow the fabrication of implant-supported, multi-unit, and full-arch restorations with screw-retained z…”
Background
Cited by
Sailer, I., Strasding, M., Valente, N. A., Zwahlen, M., Liu, S., & Pjetursson, B. E. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13277 · Cited by 273
Zembic, A., Bösch, A., Jung, R. E., Hämmerle, C. H. F., & Sailer, I. (2013) · Clinical Oral Implants Research · doi:10.1111/clr.12044 · Cited by 183
Johansson, C., Kmet, G., Rivera, J., Larsson, C., & Vult Von Steyern, P. (2014) · Acta Odontologica Scandinavica · doi:10.3109/00016357.2013.822098 · Cited by 171
“The risk of complete fracture is minimal and only a few complete fractures have been registered in studies on tooth-supported zirconia-based restorations and none in studies on implant-supported ones [2,3].”
BackgroundWear and Corrosion Interactions on Titanium in Oral Environment: Literature Review
Souza, J. C. M., Henriques, M., Teughels, W., Ponthiaux, P., Celis, J.-P., & Rocha, L. A. (2015) · Journal of Bio- and Tribo-Corrosion · doi:10.1007/s40735-015-0013-0 · Cited by 171
“Abutments made of YTZP provide better results concerning esthetic for anterior restorations although data on longterm performance of fixed partial dentures on YTZP are still lacking [20, 21].”
BackgroundRevolution of Current Dental Zirconia: A Comprehensive Review
Alqutaibi, A. Y., Ghulam, O., Krsoum, M., Binmahmoud, S., Taher, H., Elmalky, W., & Zafar, M. S. (2022) · Molecules · doi:10.3390/molecules27051699 · Cited by 142
Metadata
- Authors
- Guess, P. C., Att, W., & Strub, J. R.
- Venue
- Clinical Implant Dentistry and Related Research
- Publisher
- Wiley
- Published
- 2010-12-22
- Volume
- 14
- Issue
- 5
- Pages
- 633-645
- ISSN
- 1523-0899 (ISSN-L)
- 1708-8208
- OpenAlex
- W2119588005
- Cited by
- 192
- References
- 38
- FWCI
- 11.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.