CoChat

Penile Doppler Ultrasound in Patients with Erectile Dysfunction (ED): Role of Peak Systolic Velocity Measured in the Flaccid State in Predicting Arteriogenic ED and Silent Coronary Artery Disease

Corona, Giovanni, Fagioli, Giorgio, Mannucci, Edoardo, Romeo, Annadina, Rossi, Massimiliano, Lotti, Francesco, Sforza, Alessandra, Morittu, Stefano, Chiarini, Valerio, Casella, Gianni, Di Pasquale, Giuseppe, Bandini, Elisa, Forti, Gianni, Maggi, Mario · 2008 · The Journal of Sexual Medicine
Cited by 154

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Introduction: The use of the penile peak systolic velocity (PSV) measured in the flaccid state during penile color Doppler ultrasound (PCDU) examination has been questioned without substantial evidence. Aim: To assess the validity of PSV measured in the flaccid state during PCDU, in patients consulting for erectile dysfunction (ED). Methods: A consecutive series of 1,346 (mean age 55.0 ± 12.0 years) male patients was studied. Main Outcomes Measures: All patients underwent PCDU performed both in the flaccid state and dynamic (after prostaglandin E1 stimulation) conditions. A subset of 20 subjects with uncomplicated type 2 diabetes underwent diagnostic testing for silent coronary heart disease by means of adenosine stress myocardial perfusion scintigraphy (SPECT). In these subjects penile arterial flow was simultaneously assessed by PCDU before and after systemic adenosine administration. Results: Flaccid PSV showed a significant (r = 0.513, P < 0.0001) correlation with dynamic PSV. Receiver operating characteristic (ROC) curve analysis demonstrated that when a threshold of 13 cm/seconds was chosen, flaccid PSV was predictive for dynamic PSV < 25 and <35 cm/seconds with an accuracy of 89% and 82%, respectively. Among the subset of patients who underwent SPECT, an impaired coronary flow reserve (ICFR) occurred in nine cases (45%). When the same threshold of <13 cm/seconds was chosen, PSV before SPECT was predictive of ICFR with an accuracy of 80% (area under the ROC curve = 0.798 ± 0.10; P < 0.05). After adjustment for confounders, anxiety symptoms were related to dynamic PSV (Adj. r = −0.154, P < 0.05) but not to flaccid PSV. Conclusions: Our results show that flow in the cavernosal arteries can be routinely evaluated by PCDU in the flaccid state. Performing PCDU only in the flaccid state allows identifying subjects with pathological dynamic PSV with accuracy higher than 80%. Furthermore, our preliminary data suggest that the same examination could identify diabetic subjects with ICFR with an accuracy of 80%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1743-6109.2008.00982.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 154

Metadata

Authors
Corona, G., Fagioli, G., Mannucci, E., Romeo, A., Rossi, M., Lotti, F., Sforza, A., Morittu, S., Chiarini, V., Casella, G., Di Pasquale, G., Bandini, E., Forti, G., & Maggi, M.
Venue
The Journal of Sexual Medicine
Published
2008-11-01
Volume
5
Issue
11
Pages
2623-2634
ISSN
  • 1743-6095 (ISSN-L)
  • 1743-6109
OpenAlex
W1606055391
Cited by
154
References
4
FWCI
6.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.