Comparison of Air‐Displacement Plethysmography, Hydrodensitometry, and Dual X‐ray Absorptiometry for Assessing Body Composition of Children 10 to 18 Years of Age
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A bstract: Body density (Db) of 54 boys and girls 10–18 years of age (13.9 ± 2.4 years) was measured in an air‐displacement plethysmograph, the BOD POD®, and compared to Db determined by hydrodensitometry (HW). Both Db values were converted to percent body fat (%BF) using a two‐component model conversion formula and compared to %BF determined by dual energy X‐ray absorptiometry (DXA). Body density estimated from the BOD POD (1.04657 ± 0.01825 g/cc) was significantly higher than that estimated from HW (1.04032 ± 0.01872 g/cc). The relative body fat calculated from the BOD POD (23.12 ± 8.39 %BF) was highly correlated but, on average, 2.9% BF lower than %BF DXA. Average %BF estimates from HW and DXA were not significantly different. Despite consistently underestimating the %BF of children, the strong relationship between DXA and the BOD POD suggests that further investigation may improve the accuracy of the BOD POD for assessing body composition in children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new air displacement method for the determination of human body composition
DEMPSTER, P., & AITKENS, S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199512000-00017 · Cited by 678
Preliminary evidence that DEXA provides an accurate assessment of body composition
Kohrt, W. M. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.372 · Cited by 186
Cited by
Body-composition assessment via air-displacement plethysmography in adults and children: a review
Fields, D. A., Goran, M. I., & McCrory, M. A. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/75.3.453 · Cited by 638
Simmonds, M., Burch, J., Llewellyn, A., Griffiths, C., Yang, H., Owen, C., Duffy, S., & Woolacott, N. (2015) · Health Technology Assessment · doi:10.3310/hta19430 · Cited by 381
Ma, G., Yao, M., Liu, Y., Lin, A., Zou, H., Urlando, A., Wong, W. W., Nommsen-Rivers, L., & Dewey, K. G. (2004) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/79.4.653 · Cited by 262
Comparison of Methods to Assess Body Composition Changes during a Period of Weight Loss
Frisard, M. I., Greenway, F. L., & DeLany, J. P. (2005) · Obesity Research · doi:10.1038/oby.2005.97 · Cited by 153
Lazzer, S., Bedogni, G., Agosti, F., De Col, A., Mornati, D., & Sartorio, A. (2008) · British Journal of Nutrition · doi:10.1017/s0007114508922558 · Cited by 106
“is in agreement with previous studies((38,39)).”
Metadata
- Authors
- LOCKNER, D. W., HEYWARD, V. H., BAUMGARTNER, R. N., & JENKINS, K. A.
- Venue
- Annals of the New York Academy of Sciences
- Publisher
- Wiley
- Published
- 2000-05
- Volume
- 904
- Issue
- 1
- Pages
- 72-78
- ISSN
- 0077-8923 (ISSN-L)
- 1749-6632
- OpenAlex
- W2021144355
- Cited by
- 102
- References
- 2
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Air‐Displacement Plethysmography, Hydrodensitometry, and Dual X‐ray Absorptiometry for Assessing Body Composition of Children 10 to 18 Years of Age. https://app.cochat.ai/papers/10.1111/j.1749-6632.2000.tb06423.x
- The paper
- LOCKNER, D. W., HEYWARD, V. H., BAUMGARTNER, R. N., & JENKINS, K. A. (2000). Comparison of Air‐Displacement Plethysmography, Hydrodensitometry, and Dual X‐ray Absorptiometry for Assessing Body Composition of Children 10 to 18 Years of Age. Annals of the New York Academy of Sciences. https://doi.org/10.1111/j.1749-6632.2000.tb06423.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.