Bioreactors and Bioprocessing for Tissue Engineering
The DOI matches its Crossref record.
Abstract
A bstract: Bioreactor design in tissue engineering is complex, and at the early stages of its development. Design of biologically effective, yet scalable, devices requires intimate collaboration between engineers and biologists to ensure that all aspects are considered fully. Growth conditions, harvesting time, scale‐up, storage, and sterility issues all need to be considered and incorporated into the design of bioreactors. Each tissue‐engineered product will likely require individualized bioreactor design. However, without a comprehensive understanding of each of these components, bioreactor design and tissue growth to manufacture product will remain at a relatively rudimentary and limited level. Increased fundamental understanding of the issues can have a dramatic impact on the ability to generate tissue‐engineered product safely, economically, and in the numbers that are required to fully address the patient populations in need.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of bioreactors in tissue engineering
Martin, I., Wendt, D., & Heberer, M. (2004) · Trends in Biotechnology · doi:10.1016/j.tibtech.2003.12.001 · Cited by 1,215
Badylak, S. F., Taylor, D., & Uygun, K. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124743 · Cited by 1,041
Small-Diameter Artificial Arteries Engineered In Vitro
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Circulation Research · doi:10.1161/01.res.0000196867.12470.84 · Cited by 469
Microfabricated Biomaterials for Engineering 3D Tissues
Zorlutuna, P., Annabi, N., Camci‐Unal, G., Nikkhah, M., Cha, J. M., Nichol, J. W., Manbachi, A., Bae, H., Chen, S., & Khademhosseini, A. (2012) · Advanced Materials · doi:10.1002/adma.201104631 · Cited by 394
Bioreactors for tissue mass culture: Design, characterization, and recent advances
Martin, Y., & Vermette, P. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.057 · Cited by 390
Osteochondral tissue engineering
Martin, I., Miot, S., Barbero, A., Jakob, M., & Wendt, D. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.03.008 · Cited by 378
Bioreactor design for tissue engineering
Pörtner, R., Nagel-Heyer, S., Goepfert, C., Adamietz, P., & Meenen, N. M. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.235 · Cited by 305
“This system has a wide range of practical applications (5, 7).”
BackgroundInfluentialBioreactors for tissue engineering
Chen, H.-C., & Hu, Y.-C. (2006) · Biotechnology Letters · doi:10.1007/s10529-006-9111-x · Cited by 256
Bioreactor Systems for Bone Tissue Engineering
Rauh, J., Milan, F., Günther, K.-P., & Stiehler, M. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0612 · Cited by 225
“The supply of oxygen and soluble nutrients becomes critical when the diffusion distance exceeds a distance of 100–200 mm.(40) Studies demonstrated low expression of osteogenic marker proteins and decreased proliferation of bone marrow stromal cells under static cultivation conditions in large cell/scaffold constructs.”
Alhadlaq, A., Tang, M., & Mao, J. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.556 · Cited by 202
The emergence of ECM mechanics and cytoskeletal tension as important regulators of cell function
Peyton, S. R., Ghajar, C. M., Khatiwala, C. B., & Putnam, A. J. (2007) · Cell Biochemistry and Biophysics · doi:10.1007/s12013-007-0004-y · Cited by 188
“Unknowingly to him, Wolff would also have a huge impact on the field of tissue engineering into the 21st century, as witnessed by extensive research focused on the development of bioreactors capable of applying mechanical forces to engineered tissues, particularly those designed for musculoskeletal and cardiovascular…”
BackgroundBioreactors for Cardiovascular Cell and Tissue Growth: A Review
Barron, V., Lyons, E., Stenson-Cox, C., McHugh, P. E., & Pandit, A. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1603260 · Cited by 182
Engineering Tumors: A Tissue Engineering Perspective in Cancer Biology
Burdett, E., Kasper, F. K., Mikos, A. G., & Ludwig, J. A. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0676 · Cited by 172
Why tissue engineering needs process engineering
Archer, R., & Williams, D. J. (2005) · Nature Biotechnology · doi:10.1038/nbt1105-1353 · Cited by 101
Wu, W., Le, A. V., Mendez, J. J., Chang, J., Niklason, L. E., & Steinbacher, D. M. (2015) · Tissue Engineering Part A · doi:10.1089/ten.tea.2014.0115 · Cited by 44
“Bioreactors, such as rotational wall, spinner flasks, and perfusing devices, are designed to be more physiologic by enhancing delivery of oxygen and nutrients, as well as by imparting three-dimensional mechanical stimuli to all cells within the construct.(20) The purpose of this study is to compare adipose and bone ma…”
BackgroundSelf-citation
Metadata
- Authors
- RATCLIFFE, A., & NIKLASON, L. E.
- Venue
- Annals of the New York Academy of Sciences
- Publisher
- Wiley
- Published
- 2002-06
- Volume
- 961
- Issue
- 1
- Pages
- 210-215
- ISSN
- 0077-8923 (ISSN-L)
- 1749-6632
- OpenAlex
- W1977941490
- Cited by
- 150
- References
- 0
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.