Comparison of Two Noninvasive Devices for Measurement of Central Systolic Blood Pressure With Invasive Measurement During Cardiac Catheterization
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
J Clin Hypertens (Greenwich). 2012; 14:575–579. © 2012 Wiley Periodicals, Inc. Recently, a new device for noninvasive assessment of central systolic blood pressure (cSBP) (BPro device with A‐Pulse) was approved by the US Food and Drug Administration, but available data are limited. In 52 patients undergoing invasive elective cardiac evaluation, central hemodynamics were measured invasively. Immediately thereafter, radial artery waveforms were sampled by two noninvasive techniques, the BPro and, as a comparator, the SphygmoCor System. Then, central hemodynamics were measured invasively for a second time. The invasively recorded cSBP (137±27 mm Hg) did not differ with both noninvasively assessed cSBP by BPro (136±21 mm Hg, P=.627 vs invasive cSBP) and by SphygmoCor (136 ± 23 mm Hg, P=.694 vs invasive cSBP) and correlated highly between invasively recorded and both noninvasively assessed cSBP. However, using Bland‐Altman plots, spreading of compared data of both devices can be found (BPro: 0.87±13 mm Hg vs invasive cSBP; SphygmoCor: 0.77±14 mm Hg vs invasive cSBP). There was an excellent correlation of both noninvasive devices for the calculation of cSBP (r=0.961, P<.001). cSBP differed by only 0.1±6 mm Hg (P=.913) between the two noninvasive devices. Therefore, both noninvasive devices showed an accurate agreement in cSBP compared with invasively measured cSBP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Franklin, S. S., Larson, M. G., Khan, S. A., Wong, N. D., Leip, E. P., Kannel, W. B., & Levy, D. (2001) · Circulation · doi:10.1161/01.cir.103.9.1245 · Cited by 1,390
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
Systolic versus diastolic blood pressure and risk of coronary heart disease
Kannel, W. B., Gordon, T., & Schwartz, M. J. (1971) · The American Journal of Cardiology · doi:10.1016/0002-9149(71)90428-0 · Cited by 925
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873 · cited 1×
“Corresponding central (aortic) waveforms were then automatically generated from the radial artery waveform by a validated transfer function.(5,6,14) From the derived central waveforms, data are given for central hemodynamics.”
Method
Cited by
Central blood pressure: current evidence and clinical importance
McEniery, C. M., Cockcroft, J. R., Roman, M. J., Franklin, S. S., & Wilkinson, I. B. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht565 · Cited by 678
Hummel, S. L., Seymour, E. M., Brook, R. D., Sheth, S. S., Ghosh, E., Zhu, S., Weder, A. B., Kovács, S. J., & Kolias, T. J. (2013) · Circulation: Heart Failure · doi:10.1161/circheartfailure.113.000481 · Cited by 190
“Transthoracic echocardiography was performed using the Acuson Sequoia C512 (Siemens USA, Malvern, PA), and central BP was measured with the Sphygmocor radial artery tonometer (AtCor Medical, Itasca, IL).(17) Six-minute walk testing was performed per American Thoracic Society guidelines.”
Current Status and Prospects of Health-Related Sensing Technology in Wearable Devices
Cho, J. (2019) · Journal of Healthcare Engineering · doi:10.1155/2019/3924508 · Cited by 33
Dong, Y., Jiang, L., Wang, X., Chen, Z., Zhang, L., Zhang, Z., Zheng, C., Kang, Y., Wang, Z., Cao, H., et al. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.13838 · Cited by 22
Metadata
- Authors
- Ott, C., Haetinger, S., Schneider, M. P., Pauschinger, M., & Schmieder, R. E.
- Venue
- The Journal of Clinical Hypertension
- Publisher
- Wiley
- Published
- 2012-07-09
- Volume
- 14
- Issue
- 9
- Pages
- 575-579
- ISSN
- 1524-6175 (ISSN-L)
- 1751-7176
- OpenAlex
- W1517530811
- Cited by
- 55
- References
- 5
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Two Noninvasive Devices for Measurement of Central Systolic Blood Pressure With Invasive Measurement During Cardiac Catheterization. https://app.cochat.ai/papers/10.1111/j.1751-7176.2012.00682.x
- The paper
- Ott, C., Haetinger, S., Schneider, M. P., Pauschinger, M., & Schmieder, R. E. (2012). Comparison of Two Noninvasive Devices for Measurement of Central Systolic Blood Pressure With Invasive Measurement During Cardiac Catheterization. The Journal of Clinical Hypertension. https://doi.org/10.1111/j.1751-7176.2012.00682.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.