A Compilation of New and Published Major and Trace Element Data for NIST SRM 610 and NIST SRM 612 Glass Reference Materials
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Microanalytical trace element techniques (such as ion probe or laser ablation ICP‐MS) are hampered by a lack of well characterized, homogeneous standards. Two silicate glass reference materials produced by National Institute of Standards and Technology (NIST), NIST SRM 610 and NIST SRM 612, have been shown to be homogeneous and are spiked with up to sixty one trace elements at nominal concentrations of 500 μg g‐1 and 50 μg g‐1 respectively. These samples (supplied as 3 mm wafers) are equivalent to NIST SRM 611 and NIST SRM 613 respectively (which are supplied as 1 mm wafers) and are becoming more widely used as potential microanalytical reference materials. NIST however, only certifies up to eight elements in these glasses. Here we have compiled concentration data from approximately sixty published works for both glasses, and have produced new analyses from our laboratories. Compilations are presented for the matrix composition of these glasses and for fifty eight trace elements. The trace element data includes all available new and published data, and summaries present the overall average and standard deviation, the range, median, geometric mean and a preferred average (which excludes all data outside ± one standard deviation of the overall average). For the elements which have been certified, there is a good agreement between the compiled averages and the NIST data. This compilation is designed to provide useful new working values for these reference materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenner, G. A., Longerich, H. P., Jackson, S. E., & Fryer, B. J. (1990) · Chemical Geology · doi:10.1016/0009-2541(90)90145-w · Cited by 760
Self-citationGARBE‐SCHÖNBERG, C. (1993) · Geostandards Newsletter · doi:10.1111/j.1751-908x.1993.tb00122.x · Cited by 373
Longerich, H. P., Jenner, G. A., Fryer, B. J., & Jackson, S. E. (1990) · Chemical Geology · doi:10.1016/0009-2541(90)90143-u · Cited by 323
Self-citationHorn, I., Foley, S. F., Jackson, S. E., & Jenner, G. A. (1994) · Chemical Geology · doi:10.1016/0009-2541(94)90128-7 · Cited by 198
Self-citationA handbook of inductively coupled plasma spectrometry
Sharp, B. L. (1984) · TrAC Trends in Analytical Chemistry · doi:10.1016/0165-9936(84)80037-0 · Cited by 176
Microwave dissolution of geologic material: application to isotope dilution analysis
Fischer, L. B. (1986) · Analytical Chemistry · doi:10.1021/ac00292a066 · Cited by 112
Jeffries, T. E., Pearce, N. J. G., Perkins, W. T., & Raith, A. (1996) · Analytical Communications · doi:10.1039/ac9963300035 · Cited by 106
Self-citationFedorowich, J. S., Richards, J. P., Jain, J. C., et al. (1993) · Chemical Geology · doi:10.1016/0009-2541(93)90029-i · Cited by 103
Westgate, J. A., Perkins, W. T., Fuge, R., Pearce, N. J. G., & WINTLE, A. G. (1994) · Applied Geochemistry · doi:10.1016/0883-2927(94)90042-6 · Cited by 75
Self-citationGOVINDARAJU, K. (1984) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.1984.tb00415.x · Cited by 53
Morgan, J. W. (1987) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(87)90135-9 · Cited by 44
Determination of lithium, boron, and carbon by quasi-prompt charged particle activation analysis
McGinley, J., & Schweikert, E. A. (1975) · Analytical Chemistry · doi:10.1021/ac60364a027 · Cited by 26
GOVINDARAJU, K. (1995) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.1995.tb00152.x · Cited by 24
Stable isotope dilution analysis by thermal ionisation mass spectrometry
Broekman, A., & van Raaphorst, J. G. (1983) · Fresenius Zeitschrift für Analytische Chemie · doi:10.1007/bf00476401 · Cited by 9
Cited by
Determination of Reference Values for NIST SRM 610–617 Glasses Following ISO Guidelines
Jochum, K. P., Weis, U., Stoll, B., Kuzmin, D., Yang, Q., Raczek, I., Jacob, D. E., Stracke, A., Birbaum, K., Frick, D. A., et al. (2011) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.2011.00120.x · Cited by 2,112
Black, L. P., Kamo, S. L., Allen, C. M., Davis, D. W., Aleinikoff, J. N., Valley, J. W., Mundil, R., Campbell, I. H., Korsch, R. J., Williams, I. S., et al. (2004) · Chemical Geology · doi:10.1016/j.chemgeo.2004.01.003 · Cited by 1,944
Further Characterisation of the 91500 Zircon Crystal
Wiedenbeck, M., Hanchar, J. M., Peck, W. H., Sylvester, P., Valley, J., Whitehouse, M., Kronz, A., Morishita, Y., Nasdala, L., Fiebig, J., et al. (2004) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.2004.tb01041.x · Cited by 1,519
Yuan, H., Gao, S., Liu, X., Li, H., Günther, D., & Wu, F. (2004) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.2004.tb00755.x · Cited by 1,431
Jochum, K. P., Stoll, B., Herwig, K., Willbold, M., Hofmann, A. W., Amini, M., Aarburg, S., Abouchami, W., Hellebrand, E., Mocek, B., et al. (2006) · Geochemistry, Geophysics, Geosystems · doi:10.1029/2005gc001060 · Cited by 1,116
Metadata
- Authors
- Pearce, N. J. G., Perkins, W. T., Westgate, J. A., Gorton, M. P., Jackson, S. E., Neal, C. R., & Chenery, S. P.
- Venue
- Geostandards Newsletter
- Publisher
- Wiley
- Published
- 1997-06
- Volume
- 21
- Issue
- 1
- Pages
- 115-144
- ISSN
- 0150-5505 (ISSN-L)
- OpenAlex
- W2024436619
- Cited by
- 2,788
- References
- 14
- FWCI
- 12.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.