High management impact of Ga‐68 DOTATATE (GaTate) PET/CT for imaging neuroendocrine and other somatostatin expressing tumours

Open access
Hofman, Michael S, Kong, Grace, Neels, Oliver C, Eu, Peter, Hong, Emily, Hicks, Rodney J · 2012 · Journal of Medical Imaging and Radiation Oncology
Cited by 251

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

Introduction: Ga‐68 DOTATATE (Ga‐octreotate, GaTate) positron emission tomography (PET)/CT has multiple advantages compared with conventional and In‐111 octreotide imaging for neuroendocrine tumours and other somatostatin‐receptor expressing tumours. This study assesses the management impact of incremental diagnostic information obtained from this technique compared with conventional staging. Methods: Fifty‐nine GaTate PET/CT studies were performed over an 18‐month period (52 proven or suspected gastro‐entero‐pancreatic or bronchial neuroendocrine tumours and seven neural crest/mesenchymal tumours). A retrospective blinded review was performed on the number of abnormalities (1, 2–5 or >5) within defined regions with comparison to conventional imaging to assess incremental diagnostic information. Subsequent management impact (high, moderate or low) was determined by clinical review and follow up to assess pre‐PET stage, treatment intent and post‐PET management change. Results: Eighty‐eight percent of GaTate studies were abnormal. Compared with conventional and In‐111 octreotide imaging, additional information was provided by GaTate PET/CT in 68 and 83% of patients, respectively. Management impact was high (inter‐modality change) in 47%, moderate (intra‐modality change) in 10% and low in 41% (not assessable in 2%). High management impact included directing patients to curative surgery by identifying a primary site and directing patients with multiple metastases to systemic therapy. Conclusion: GaTate PET/CT imaging provides additional diagnostic information in a high proportion of patients with consequent high management impact. GaTate PET/CT could replace 1 In‐111 octreotide scintigraphy at centres where it is available given its superior accuracy, faster acquisition and lower radiation exposure. Rapid implementation could be achieved by allowing substitutional funding in the Medicare Benefit Schedule.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1754-9485.2011.02327.x

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

Metadata

Authors
Hofman, M. S., Kong, G., Neels, O. C., Eu, P., Hong, E., & Hicks, R. J.
Venue
Journal of Medical Imaging and Radiation Oncology
Publisher
Wiley
Published
2012-02
Volume
56
Issue
1
Pages
40-47
ISSN
  • 1754-9477 (ISSN-L)
  • 1754-9485
OpenAlex
W1565486843
Cited by
251
References
22
FWCI
14.22
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.