CoChat

Use of the retinal vessel analyzer in ocular blood flow research

Open access
Garhofer, Gerhard, Bek, Toke, Boehm, Andreas G., Gherghel, Doina, Grunwald, Juan, Jeppesen, Peter, Kergoat, Hélène, Kotliar, Konstantin, Lanzl, Ines, Lovasik, John V., Nagel, Edgar, Vilser, Walthard, Orgul, Selim, Schmetterer, Leopold · 2010 · Acta Ophthalmologica
Cited by 224

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Acta Ophthalmol. 2010: 88: 717–722 Abstract.: The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1755-3768.2009.01587.x

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 224

Metadata

Authors
Garhofer, G., Bek, T., Boehm, A. G., Gherghel, D., Grunwald, J., Jeppesen, P., Kergoat, H., Kotliar, K., Lanzl, I., Lovasik, J. V., Nagel, E., Vilser, W., Orgul, S., & Schmetterer, L.
Venue
Acta Ophthalmologica
Publisher
Wiley
Published
2009-08-14
Volume
88
Issue
7
Pages
717-722
ISSN
  • 0001-639X (ISSN-L)
  • 1755-375X
  • 1755-3768
OpenAlex
W2041245457
Cited by
224
References
15
FWCI
9.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.