Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 176

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

His bundle pacing, learning curve, procedure characteristics, safety, and feasibility: Insights from a large international observational study

Open access
Keene, Daniel, Arnold, Ahran D, Jastrzębski, Marek, Burri, Haran, Zweibel, Steven, Crespo, Eric, Chandrasekaran, Badrinathan, Bassi, Sukhbinder, Joghetaei, Nader, Swift, Matthew, Moskal, Pawel, Francis, Darrel P, Foley, Paul, Shun‐Shin, Matthew J, Whinnett, Zachary I · 2019 · Journal of Cardiovascular Electrophysiology

Abstract

Background: His‐bundle pacing (HBP) provides physiological ventricular activation. Observational studies have demonstrated the techniques’ feasibility; however, data have come from a limited number of centers. Objectives: We set out to explore the contemporary global practice in HBP focusing on the learning curve, procedural characteristics, and outcomes. Methods: This is a retrospective, multicenter observational study of patients undergoing attempted HBP at seven centers. Pacing indication, fluoroscopy time, HBP thresholds, and lead reintervention and deactivation rates were recorded. Where centers had systematically recorded implant success rates from the outset, these were collated. Results: A total of 529 patients underwent attempted HBP during the study period (2014‐19) with a mean follow‐up of 217 ± 303 days. Most implants were for bradycardia indications. In the three centers with the systematic collation of all attempts, the overall implant success rate was 81%, which improved to 87% after completion of 40 cases. All seven centers reported data on successful implants. The mean fluoroscopy time was 11.7 ± 12.0 minutes, the His‐bundle capture threshold at implant was 1.4 ± 0.9 V at 0.8 ± 0.3 ms, and it was 1.3 ± 1.2 V at 0.9 ± 0.2 ms at last device check. HBP lead reintervention or deactivation (for lead displacement or rise in threshold) occurred in 7.5% of successful implants. There was evidence of a learning curve: fluoroscopy time and HBP capture threshold reduced with greater experience, plateauing after approximately 30‐50 cases. Conclusion: We found that it is feasible to establish a successful HBP program, using the currently available implantation tools. For physicians who are experienced at pacemaker implantation, the steepest part of the learning curve appears to be over the first 30‐50 cases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jce.14064

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 176

Metadata

Authors
Keene, D., Arnold, A. D., Jastrzębski, M., Burri, H., Zweibel, S., Crespo, E., Chandrasekaran, B., Bassi, S., Joghetaei, N., Swift, M., Moskal, P., Francis, D. P., Foley, P., Shun‐Shin, M. J., & Whinnett, Z. I.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2019-08-02
Volume
30
Issue
10
Pages
1984-1993
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2961541696
Cited by
176
References
2
FWCI
16.14
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: His bundle pacing, learning curve, procedure characteristics, safety, and feasibility: Insights from a large international observational study. https://app.cochat.ai/papers/10.1111/jce.14064
The paper
Keene, D., Arnold, A. D., Jastrzębski, M., Burri, H., Zweibel, S., Crespo, E., Chandrasekaran, B., Bassi, S., Joghetaei, N., Swift, M., Moskal, P., Francis, D. P., Foley, P., Shun‐Shin, M. J., & Whinnett, Z. I. (2019). His bundle pacing, learning curve, procedure characteristics, safety, and feasibility: Insights from a large international observational study. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.14064

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.