Impact of the Number of Blood Pressure Measurements on Blood Pressure Classification in US Adults: NHANES 1999–2008
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
J Clin Hypertens (Greenwich). 2012;14:751–759. ©2012 Wiley Periodicals, Inc. Clinical guidelines recommend averaging ≥2 blood pressure (BP) measurements on each visit. Only one BP is measured on many clinical visits, especially if the value is <120/<80 mm Hg, ie, normal. The impact of this practice on accurate assignment of BP category is incompletely defined. Data were analyzed from 22,641 adults 18 years and older who had 3 BP readings in the National Health and Nutrition Examination Surveys 1999–2008. BP category defined by initial measurement was compared with the category determined by mean of the first and second, first through third, and second and third readings. Among 8553 nonhypertensive patients with initial BP <120/<80 mm Hg, 2.9%, 3.3%, and 6.7%, respectively, were reclassified as prehypertensive, ie, BP 120–139/80–89 mm Hg, and two patients as stage 1 hypertension (140–159/90–99 mm Hg). In 733 treated hypertensive patients with initial BP <120/<80 mm Hg, 5.1%–8.9% were reclassified as prehypertensive and only one patient as hypertensive. Among nonhypertensive and hypertensive patients with initial BP in the prehypertensive range, 8.0%–23.6% were reclassified as normal. Among stage 1 and 2 hypertensive patients based on initial BP, 18.2%–33.5% were reclassified to lower BP categories. By multivariable logistic regression, older age and higher systolic and diastolic BP were associated with reclassification to a lower BP category. In nonhypertensive and hypertensive patients with normal initial BP values, one BP measurement appears adequate as <10% are re‐classified as prehypertensive and <0.5% as hypertensive. In contrast, patients with an initial BP above normal are often reclassified to a lower category, which supports recommendations for additional measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Cardiovascular Survey Methods.
(1968) · Annals of Internal Medicine · doi:10.7326/0003-4819-69-6-1335_2 · Cited by 3,052
US trends in prevalence, awareness, treatment, and control of hypertension, 1988–2008
Egan, B. M. (2010) · JAMA · doi:10.1001/jama.2010.650 · Cited by 2,197 · cited 12×
“BP Measurement BP in NHANES 1999–2008 was measured by trained physicians using mercury sphygmomanometry and appropriately sized arm cuffs after volunteers rested for 5 minutes while seated.(4,9)”
BackgroundMethodInfluentialSelf-citationPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Prevalence, Awareness, Treatment, and Control of Hypertension Among United States Adults 1999–2004
Ong, K. L., Cheung, B. M. Y., Man, Y. B., Lau, C. P., & Lam, K. S. L. (2007) · Hypertension · doi:10.1161/01.hyp.0000252676.46043.18 · Cited by 1,395
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“A study of US adults estimated that 35% of people with SBP/DBP on their first BP measurement of 140 to 159/90 to 99 mm Hg had SBP/DBP <140/90 mm Hg when the average of 3 measurements was used.(68) In addition, 24% of participants with SBP/DBP of 120 to 139/80 to 89 mm Hg based on their first clinic measurement had SBP…”
BackgroundPiper, M. A., Evans, C. V., Burda, B. U., Margolis, K. L., O'Connor, E., & Whitlock, E. P. (2015) · Annals of Internal Medicine · doi:10.7326/m14-1539 · Cited by 380
Egan, B. M., Li, J., Qanungo, S., & Wolfman, T. E. (2013) · Circulation · doi:10.1161/circulationaha.112.000500 · Cited by 150
“and leads to lower BP control rates when included in the mean.(46) Our report also includes as hypertensive individuals”
BackgroundSelf-citationEgan, B. M., Sutherland, S. E., Rakotz, M., Yang, J., Hanlin, R. B., Davis, R. A., & Wozniak, G. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.11558 · Cited by 104
Self-citation
Metadata
- Authors
- Handler, J., Zhao, Y., & Egan, B. M.
- Venue
- The Journal of Clinical Hypertension
- Publisher
- Wiley
- Published
- 2012-10-22
- Volume
- 14
- Issue
- 11
- Pages
- 751-759
- ISSN
- 1524-6175 (ISSN-L)
- 1751-7176
- OpenAlex
- W1573341604
- Cited by
- 80
- References
- 5
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.