A Short History of Automated Office Blood Pressure – 15 Years to SPRINT
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The term "automated office blood pressure" (AOBP) refers to BP measurements obtained using a fully automated electronic sphygmomanometer that records multiple BP readings with the patient resting undisturbed in a quiet place without medical staff being present.1 This article describes the relatively rapid evolution of AOBP from validation studies in 2001 to becoming the preferred method for recording office BP in evidence-based guidelines. The story of AOBP parallels the increased interest in white coat effect (WCE) associated with office BP which is not seen with AOBP measurement.1 In 1984, Tom Pickering and colleagues2 introduced the term "white coat hypertension" (WCH) to describe untreated patients with a high BP in the office and normal BP at home. In 1991, the concept of WCH was extended further, by denoting patients who were already being treated with antihypertensive therapy as having a "white coat effect" if systolic/diastolic office BP was at least 20 and/or 10 Hg higher than awake ambulatory BP.3 The minimum difference of 20 and/or 10 mm Hg was selected because it was considered to be "clinically important," enough to alter patient management. Also, WCE could be applied to all patients, regardless of treatment status. These definitions are still in use, along with the non-specific terms "white coat phenomenon" and "white coat response." In 1997, Myers and colleagues4 attempted to eliminate WCE by having patients take their own BP with an electronic home BP recorder while they were seated alone in an examining room. However, under these conditions, some WCE was still present. Shortly thereafter, Gelfer and colleagues at a Canadian medical technology company, VSM MedTech developed the BpTRU, an electronic sphygmomanometer which was capable of automatically taking an initial test reading followed by five readings one or more minutes apart, with the patient resting quietly and alone. Their objective was to reduce WCE by decreasing anxiety associated with the process of BP self-measurement in the office. At this time, a second fully automated, electronic sphygmomanometer, the Omron HEM-907 (Omron Healthcare, Lake Forest, IL, USA), became available for research in AOBP measurement. Both devices were validated for accuracy according to standard protocols.5-7 Subsequently, the Omron device would receive little attention from the scientific community until re-appearing in 2015 in the SPRINT study. Beckett and Godwin created considerable interest in AOBP and the WCE in 20058 when they reported that BpTRU readings in 481 patients being treated by family physicians in the community reduced routine office BP by 11/3 mm Hg, with the mean automated BpTRU reading being similar to the mean awake ambulatory BP (Table). The multiple readings automatically taken with the BpTRU device with the patient resting quietly and alone became known as "automated office BP" (AOBP) measurement. Within a year, several major research studies using the BpTRU were initiated. Kaczorowski and colleagues9 used the BpTRU for AOBP measurement in the Cardiovascular Health Awareness Program (CHAP), a randomized controlled trial which included BP screening in the community. CHAP is still unique in being the only study in hypertension to demonstrate that screening BP in thousands of community-dwelling subjects can lead to a reduction in hospitalization for cardiovascular events in the future. Leenen and colleagues10 became the first researchers to use AOBP in a community BP survey. AOBP was seen to have several advantages over manual BP including more accurate and consistent readings without the need for extensive training of research staff. The Ontario Survey on the Prevalence of High Blood Pressure (ON-BP) recorded AOBP using the BpTRU in 2551 adult subjects, with BP readings also being performed using a standard mercury sphygmomanometer in a sample (n=238) of this population.11 As expected, the AOBP readings were slightly lower (115/71 mm Hg) than the mean manual BP (118/74 mm Hg). Even after adjustment for the differences in BP, treatment and control rates in this population were surprisingly high (65%). Subsequently, Wilkins and colleagues12 reproduced these findings in a national Canadian health survey, using the BpTRU to assess BP status. Also in 2006, Myers and colleagues13 undertook a comparison of AOBP vs manual BP in routine clinical practice in the Conventional vs Automated Measurement of Blood Pressure in the Office (CAMBO) trial. In CAMBO, 555 hypertensive patients residing in 5 urban centers in Eastern Canada were cluster randomized by physician practices to management of their hypertension with either AOBP using the BpTRU or conventional manual BP measurement. In this study, mean AOBP was similar to the mean awake ambulatory BP with both measurements being significantly lower that the manual BP readings in the control group (Table). AOBP also exhibited a significantly stronger correlation with the mean awake ambulatory BP co
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Randomized Trial of Intensive versus Standard Blood-Pressure Control
The SPRINT Research Group (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1511939 · Cited by 6,325
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
de la Sierra, A., Segura, J., Banegas, J. R., Gorostidi, M., de la Cruz, J. J., Armario, P., Oliveras, A., & Ruilope, L. M. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.168948 · Cited by 809
Measurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
Self-citation
Cited by
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Diretrizes Brasileiras de Hipertensão Arterial – 2020
Barroso, W. K. S., Rodrigues, C. I. S., Bortolotto, L. A., Mota-Gomes, M. A., Brandão, A. A., Feitosa, A. D. D. M., Machado, C. A., Poli-de-Figueiredo, C. E., Amodeo, C., Mion, D., et al. (2021) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20201238 · Cited by 1,068
Blood Pressure Measurement in SPRINT (Systolic Blood Pressure Intervention Trial)
Johnson, K. C., Whelton, P. K., Cushman, W. C., Cutler, J. A., Evans, G. W., Snyder, J. K., Ambrosius, W. T., Beddhu, S., Cheung, A. K., Fine, L. J., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10479 · Cited by 240
Metadata
- Authors
- Myers, M. G.
- Venue
- The Journal of Clinical Hypertension
- Publisher
- Wiley
- Published
- 2016-04
- Volume
- 18
- Issue
- 8
- Pages
- 721-724
- ISSN
- 1524-6175 (ISSN-L)
- 1751-7176
- OpenAlex
- W2332802041
- Cited by
- 95
- References
- 4
- FWCI
- 13.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.