CoChat

Strength and Surface Properties of a 3D‐Printed Denture Base Polymer

Gad, Mohammed M., Fouda, Shaimaa M., Abualsaud, Reem, Alshahrani, Faris A., Al‐Thobity, Ahmad M., Khan, Soban Q., Akhtar, Sultan, Ateeq, Ijlal Shahrukh, Helal, Mohamed A., Al‐Harbi, Fahad A. · 2022 · Journal of Prosthodontics
Cited by 240

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Purpose: This in vitro study evaluated the flexural strength, impact strength, hardness, and surface roughness of 3D‐printed denture base resin subjected to thermal cycling treatment. Materials and Methods: According to ISO 20795‐1:2013 standards, 120 acrylic resin specimens (40/flexural strength test, 40/impact strength, and 40/surface roughness and hardness test, n = 10) were fabricated and distributed into two groups: heat‐polymerized; (Major.Base.20) as control and 3D‐printed (NextDent) as experimental group. Half of the specimens of each group were subjected to 10,000 thermal cycles of 5 to 55°C simulating 1 year of clinical use. Flexural strength (MPa), impact strength (KJ/m 2), hardness (VHN), and surface roughness (μm) were measured using universal testing machine, Charpy's impact tester, Vickers hardness tester, and profilometer, respectively. Data were analyzed by ANOVA and Tukey honestly significant difference (HSD) test (α = 0.05). Results: The values of flexural strength (MPa) were 86.63 ± 1.0 and 69.15 ± 0.88; impact strength (KJ/m 2)—6.32 ± 0.50 and 2.44 ± 0.31; hardness (VHN)—41.63 ± 2.03 and 34.62 ± 2.1; and surface roughness (μm)—0.18 ± 0.01 and 0.12 ± 0.02 for heat‐polymerized and 3D‐printed denture base materials, respectively. Significant differences in all tested properties were recorded between heat‐polymerized and 3D‐printed denture base materials (P < 0.001). Thermal cycling significantly lowered the flexural strength (63.93 ± 1.54 MPa), impact strength (2.40 ± 0.35 KJ/m 2), and hardness (30.17 ± 1.38 VHN) of 3D‐printed resin in comparison to thermal cycled heat‐polymerized resin, but surface roughness showed non‐significant difference (p = 0.262). Conclusion: 3D‐printed resin had inferior flexural strength, impact strength, and hardness values than heat‐polymerized resin, but showed superior surface roughness. Temperature changes (thermal cycling) significantly reduced the hardness and flexural strength and increased surface roughness, but did not affect the impact strength.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jopr.13413

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Gad, M. M., Fouda, S. M., Abualsaud, R., Alshahrani, F. A., Al‐Thobity, A. M., Khan, S. Q., Akhtar, S., Ateeq, I. S., Helal, M. A., & Al‐Harbi, F. A.
Venue
Journal of Prosthodontics
Publisher
Wiley
Published
2021-08-25
Volume
31
Issue
5
Pages
412-418
ISSN
  • 1059-941X (ISSN-L)
  • 1532-849X
OpenAlex
W3191567004
Cited by
240
References
15
FWCI
35.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.