Estimating sleep from multisensory armband measurements: validity and reliability in teens
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Summary: Given the recognition that sleep may influence obesity risk, there is increasing interest in measuring sleep parameters within obesity studies. The goal of the current analyses was to determine whether the SenseWear® Pro3 Armband (armband), typically used to assess physical activity, is reliable at assessing sleep parameters. The armband was compared with the AMI Motionlogger® (actigraph), a validated activity monitor for sleep assessment, and with polysomnography, the gold standard for assessing sleep. Participants were 20 adolescents (mean age = 15.5 years) with a mean body mass index percentile of 63.7. All participants wore the armband and actigraph on their non‐dominant arm while in‐lab during a nocturnal polysomnographic recording (600 min). Epoch‐by‐epoch sleep/wake data and concordance of sleep parameters were examined. No significant sleep parameter differences were found between the armband and polysomnography; the actigraph tended to overestimate sleep and underestimate wake compared with polysomnography. Both devices showed high sleep sensitivity, but lower wake detection rates. Bland–Altman plots showed large individual differences in armband sleep parameter concordance rates. The armband did well estimating sleep overall, with group results more similar to polysomnography than the actigraph; however, the armband was less accurate at an individual level than the actigraph.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-Analysis of Short Sleep Duration and Obesity in Children and Adults
Cappuccio, F. P., Taggart, F. M., Kandala, N.-B., Currie, A., Peile, E., Stranges, S., & Miller, M. A. (2008) · Sleep · doi:10.1093/sleep/31.5.619 · Cited by 2,076
Activity-Based Sleep-Wake Identification: An Empirical Test of Methodological Issues
Sadeh, A., Sharkey, M., & Carskadon, M. A. (1994) · Sleep · doi:10.1093/sleep/17.3.201 · Cited by 1,487
Self-citationMorgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Marino, M., Li, Y., Rueschman, M. N., Winkelman, J. W., Ellenbogen, J. M., Solet, J. M., Dulin, H., Berkman, L. F., & Buxton, O. M. (2013) · Sleep · doi:10.5665/sleep.3142 · Cited by 1,056
Slow-wave sleep and the risk of type 2 diabetes in humans
Tasali, E., Leproult, R., Ehrmann, D. A., & Van Cauter, E. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706446105 · Cited by 921
Metabolic consequences of sleep and sleep loss
Van Cauter, E., Spiegel, K., Tasali, E., & Leproult, R. (2008) · Sleep Medicine · doi:10.1016/s1389-9457(08)70013-3 · Cited by 812 · cited 3×
“…schedules are associated with being overweight or obese (Bell and Zimmerman, 2010; Cappuccio et al., 2008; Chaput et al., 2010, 2012; Garaulet et al., 2011; Hasler et al., 2004; Ievers-Landis et al., 2008; Moore et al., 2011; Tasali and Ip, 2008; Tasali et al., 2008; Van Cauter et al., 2008).”
BackgroundAcebo, C., Sadeh, A., Seifer, R., Tzischinsky, O., Wolfson, A. R., Hafer, A., & Carskadon, M. A. (1999) · Sleep · doi:10.1093/sleep/22.1.95 · Cited by 721
Self-citationHasler, G., Buysse, D. J., Klaghofer, R., Gamma, A., Ajdacic, V., Eich, D., Rössler, W., & Angst, J. (2004) · Sleep · doi:10.1093/sleep/27.4.661 · Cited by 672 · cited 2×
“…schedules are associated with being overweight or obese (Bell and Zimmerman, 2010; Cappuccio et al., 2008; Chaput et al., 2010, 2012; Garaulet et al., 2011; Hasler et al., 2004; Ievers-Landis et al., 2008; Moore et al., 2011; Tasali and Ip, 2008; Tasali et al., 2008; Van Cauter et al., 2008).”
BackgroundDANKER‐HOPFE, H., ANDERER, P., ZEITLHOFER, J., BOECK, M., DORN, H., GRUBER, G., HELLER, E., LORETZ, E., MOSER, D., PARAPATICS, S., et al. (2009) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2008.00700.x · Cited by 417
Obstructive Sleep Apnea and Metabolic Syndrome: Alterations in Glucose Metabolism and Inflammation
Tasali, E., & Ip, M. S. M. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-139mg · Cited by 365 · cited 2×
“…schedules are associated with being overweight or obese (Bell and Zimmerman, 2010; Cappuccio et al., 2008; Chaput et al., 2010, 2012; Garaulet et al., 2011; Hasler et al., 2004; Ievers-Landis et al., 2008; Moore et al., 2011; Tasali and Ip, 2008; Tasali et al., 2008; Van Cauter et al., 2008).”
Background
Cited by
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
A validation study of Fitbit Charge 2™ compared with polysomnography in adults
de Zambotti, M., Goldstone, A., Claudatos, S., Colrain, I. M., & Baker, F. C. (2018) · Chronobiology International · doi:10.1080/07420528.2017.1413578 · Cited by 413
The Sleep of the Ring: Comparison of the ŌURA Sleep Tracker Against Polysomnography
de Zambotti, M., Rosas, L., Colrain, I. M., & Baker, F. C. (2019) · Behavioral Sleep Medicine · doi:10.1080/15402002.2017.1300587 · Cited by 287
“…SOL, TST, and WASO of the current study were narrow or comparable to that of previous investigations about the validity of other commercially available fitness-trackers in adolescent samples (de Zambotti, Baker, et al., 2015; de Zambotti, Baker, et al., 2016; Roane et al., 2015; Toon et al., 2015).”
ResultGodino, J. G., Wing, D., de Zambotti, M., Baker, F. C., Bagot, K., Inkelis, S., Pautz, C., Higgins, M., Nichols, J., Brumback, T., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237719 · Cited by 107
“[15,30,31] The agreement between measures from the Fitbit Charge HR and corresponding researchgrade measures were examined using the Bland-Altman method.”
MethodLee, P. H., & Suen, L. K. P. (2017) · Sleep And Breathing · doi:10.1007/s11325-016-1406-0 · Cited by 60
Metadata
- Authors
- Roane, B. M., Van Reen, E., Hart, C. N., Wing, R., & Carskadon, M. A.
- Venue
- Journal of Sleep Research
- Publisher
- Wiley
- Published
- 2015-07
- Volume
- 24
- Issue
- 6
- Pages
- 714-721
- ISSN
- 0962-1105 (ISSN-L)
- 1365-2869
- OpenAlex
- W2136883715
- Cited by
- 43
- References
- 13
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimating sleep from multisensory armband measurements: validity and reliability in teens. https://app.cochat.ai/papers/10.1111/jsr.12317
- The paper
- Roane, B. M., Van Reen, E., Hart, C. N., Wing, R., & Carskadon, M. A. (2015). Estimating sleep from multisensory armband measurements: validity and reliability in teens. Journal of Sleep Research. https://doi.org/10.1111/jsr.12317
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.