CoChat

Liver fibrosis by FibroScan® independently of established cardiovascular risk parameters associates with macrovascular and microvascular complications in patients with type 2 diabetes

Open access
Lombardi, Rosa, Airaghi, Lorena, Targher, Giovanni, Serviddio, Gaetano, Maffi, Gabriele, Mantovani, Alessandro, Maffeis, Claudio, Colecchia, Antonio, Villani, Rosanna, Rinaldi, Luca, Orsi, Emanuela, Pisano, Giuseppina, Adinolfi, Luigi E., Fargion, Silvia, Fracanzani, Anna L. · 2020 · Liver International
Cited by 87

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Background & Aims: Non‐alcoholic fatty liver disease (NAFLD) and type 2 diabetes mellitus (T2DM) are closely associated, and liver fibrosis has been related to macrovascular complications. We examined whether liver fibrosis, diagnosed by FibroScan®, correlates with chronic vascular complications in a cohort of T2DM. Methods: We recruited 394 outpatients with T2DM attending five Italian diabetes centres who underwent liver ultrasonography (US), FibroScan® and extensive evaluation of macrovascular and microvascular diabetic complications. Results: Steatosis by US was present in 89%. Almost all patients (96%) were on hypoglycaemic drugs, 58% had at least one chronic vascular complication, 19% a macrovascular complication (prior myocardial infarction and/or ischaemic stroke) and 33% a microvascular one (26% chronic kidney disease [CKD]; 16% retinopathy; 6% neuropathy). In all, 171 (72%) patients had CAP ≥ 248dB/m (ie hepatic steatosis), whereas 83 (21%) patients had LSM ≥ 7.0/6.2 kPa (M/XL probes) (significant liver fibrosis). CAP was not associated with any macro/microvascular complications, whereas LSM ≥ 7.0/6.2 kPa was independently associated with prior cardiovascular disease (adjusted OR 3.3, 95%CI 1.2‐8.8; P = .02) and presence of microvascular complications (adjusted OR 4.2, 95%CI 1.5‐11.4; P = .005), mainly CKD (adjusted OR 3.6, 95%CI 1.3‐10.1; P = .01) and retinopathy (adjusted OR 3.7, CI 95% 1.2‐11.9; P = .02). Neither diabetes duration nor haemoglobin A1c differed according to CAP or LSM values. Conclusion: Significant fibrosis, detected by FibroScan®, is independently associated with increased prevalence of macrovascular and microvascular complications, thus opening a new scenario in the use of this tool for a comprehensive evaluation of hepatic and vascular complications in patients with T2DM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/liv.14274

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Lombardi, R., Airaghi, L., Targher, G., Serviddio, G., Maffi, G., Mantovani, A., Maffeis, C., Colecchia, A., Villani, R., Rinaldi, L., Orsi, E., Pisano, G., Adinolfi, L. E., Fargion, S., & Fracanzani, A. L.
Venue
Liver International
Publisher
Wiley
Published
2019-10-31
Volume
40
Issue
2
Pages
347-354
ISSN
  • 0106-9543 (ISSN-L)
  • 1478-3223
  • 1478-3231
OpenAlex
W2981196996
Cited by
87
References
10
FWCI
6.62
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.