CoChat

Use of an artificial pancreas among adolescents for a missed snack bolus and an underestimated meal bolus: AP in adolescents for insulin omission

Cherñavvsky, Daniel R, DeBoer, Mark D, Keith-Hynes, Patrick, Mize, Benton, McElwee, Molly, Demartini, Susan, Dunsmore, Spencer F, Wakeman, Christian, Kovatchev, Boris P, Breton, Marc D · 2016 · Pediatric Diabetes
Cited by 68

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The objective of this study was to evaluate the safety and performance of the artificial pancreas (AP) in adolescents with type 1 diabetes (T1D) following insulin omission for food. RESEARCH DESIGN AND METHODS: In a randomized, cross-over trial, adolescents with T1D aged 13-18 yr were enrolled in a randomized, cross-over trial. On separate days, received either usual care (UC) through their home insulin pump or used an AP system (Diabetes Assistant platform, continuous glucose monitor, and insulin pump). Approximately 1 h after admission, participants in both groups received an unannounced snack of 30 g carbohydrate, and 4 h later they received an 80 g lunch, for which both groups only received 75% of the calculated insulin dose to cover carbohydrates. On the UC day (but not the AP day), they received their full high blood glucose (BG) correction factor at lunch. Each admission lasted approximately 8 h. RESULTS: A total of 16 participants completed the trial. On the AP day (compared to UC), mean BG was lower (197 ± 10 vs. 235 ± 14 mg/dL) and time in range 70-180 mg/dL was higher (43% ± 7 vs. 19% ± 7) (both p < 0.05) overall; these results held in the time following the snack and meal (also p < 0.05). During the trial, there were no differences between groups in the rate of hypoglycemia <70 mg/dL. CONCLUSIONS: The AP provided improvements in short-term glycemic control without increases in hypoglycemia following missed insulin for food in adolescents. Thus, the AP partly compensates for missed insulin boluses for food, a common occurrence in adolescent diabetes care. Further testing is needed in longer-term settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/pedi.12230

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 68

Metadata

Authors
Cherñavvsky, D. R., DeBoer, M. D., Keith-Hynes, P., Mize, B., McElwee, M., Demartini, S., Dunsmore, S. F., Wakeman, C., Kovatchev, B. P., & Breton, M. D.
Venue
Pediatric Diabetes
Published
2014-10-27
Volume
17
Issue
1
Pages
28-35
ISSN
1399-543X (ISSN-L)
OpenAlex
W2168463931
Cited by
68
References
7
FWCI
2.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of an artificial pancreas among adolescents for a missed snack bolus and an underestimated meal bolus: AP in adolescents for insulin omission. https://app.cochat.ai/papers/10.1111/pedi.12230
The paper
Cherñavvsky, D. R., DeBoer, M. D., Keith-Hynes, P., Mize, B., McElwee, M., Demartini, S., Dunsmore, S. F., Wakeman, C., Kovatchev, B. P., & Breton, M. D. (2016). Use of an artificial pancreas among adolescents for a missed snack bolus and an underestimated meal bolus: AP in adolescents for insulin omission. Pediatric Diabetes. https://doi.org/10.1111/pedi.12230

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.