International guidelines for the in vivo assessment of skin properties in non‐clinical settings: Part 2. transepidermal water loss and skin hydration
Open accessThe DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Abstract
Background: There is an emerging perspective that it is not sufficient to just assess skin exposure to physical and chemical stressors in workplaces, but that it is also important to assess the condition, i.e. skin barrier function of the exposed skin at the time of exposure. The workplace environment, representing a non‐clinical environment, can be highly variable and difficult to control, thereby presenting unique measurement challenges not typically encountered in clinical settings. Methods: An expert working group convened a workshop as part of the 5th International Conference on Occupational and Environmental Exposure of Skin to Chemicals (OEESC) to develop basic guidelines and best practices (based on existing clinical guidelines, published data, and own experiences) for the in vivo measurement of transepidermal water loss (TEWL) and skin hydration in non‐clinical settings with specific reference to the workplace as a worst‐case scenario. Results: Key elements of these guidelines are: (i) to minimize or recognize, to the extent feasible, the influences of relevant endogenous‐, exogenous‐, environmental‐ and measurement/instrumentation‐related factors; (ii) to measure TEWL with a closed‐chamber type instrument; (iii) report results as a difference or percent change (rather than absolute values); and (iv) accurately report any notable deviations from this guidelines. Conclusion: It is anticipated that these guidelines will promote consistent data reporting, which will facilitate inter‐comparison of study results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The skin: an indispensable barrier
Proksch, E., Brandner, J. M., & Jensen, J. (2008) · Experimental Dermatology · doi:10.1111/j.1600-0625.2008.00786.x · Cited by 2,054 · cited 3×
“Furthermore, elevated TEWL values in a disturbed skin barrier are frequently correlated with low hydration of the SC (3).”
BackgroundPinnagoda, J., Tupkek, R. A., Agner, T., & Serup, J. (1990) · Contact Dermatitis · doi:10.1111/j.1600-0536.1990.tb01553.x · Cited by 1,092
Self-citationThe skin barrier in healthy and diseased state
Bouwstra, J. A., & Ponec, M. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.06.021 · Cited by 666
Skin hydration: A review on its molecular mechanisms
Verdier‐Sévrain, S., & Bonté, F. (2007) · Journal of Cosmetic Dermatology · doi:10.1111/j.1473-2165.2007.00300.x · Cited by 605 · cited 1×
“Skin hydration is, therefore, measured as the total impedance applied to the skin or alternatively as electrical conductance (reciprocal of resistance) or capacitance (13, 34, 35).”
BackgroundEEMCO Guidance for the Assessment of Transepidermal Water Loss in Cosmetic Sciences
Rogiers, V. (2001) · Skin Pharmacology and Physiology · doi:10.1159/000056341 · Cited by 525 · cited 4×
“Sweating from thermal, emotional, and physical mechanisms increases TEWL and skin hydration values (62, 63), but can be controlled by allowing for adequate acclimatization of subjects to the measurement environment and performing measurements under specific conditions of ambient temperature and humidity (7, 27, 28).”
BackgroundInfluentialEEMCO guidance for the assessment of stratum corneum hydration: electrical methods
Berardesca, E., & European Group for Efficacy Measurements on Cosmetics and Other Topical Products (EEMCO) (1997) · Skin Research and Technology · doi:10.1111/j.1600-0846.1997.tb00174.x · Cited by 493 · cited 3×
“Sweating from thermal, emotional, and physical mechanisms increases TEWL and skin hydration values (62, 63), but can be controlled by allowing for adequate acclimatization of subjects to the measurement environment and performing measurements under specific conditions of ambient temperature and humidity (7, 27, 28).”
BackgroundHandbook of Non-Invasive Methods and the Skin
(2006) · CRC Press eBooks · doi:10.3109/9781420003307 · Cited by 460
Feingold, K. R. (2007) · Journal of Lipid Research · doi:10.1194/jlr.r700013-jlr200 · Cited by 459
Ethnic skin types: are there differences in skin structure and function? 1
Rawlings, A. V. (2006) · International Journal of Cosmetic Science · doi:10.1111/j.1467-2494.2006.00302.x · Cited by 389
Yosipovitch, G., Xiong, G. L., Haus, E., Sackett-Lundeen, L., Ashkenazi, I., & Maibach, H. I. (1998) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.1998.00069.x · Cited by 320 · cited 2×
“Some reports suggest that circadian rhythmicity exists for forearm and facial TEWL (64, 66), while others report no diurnal variation in TEWL or a decrease in TEWL values during the day (58, 64).”
Background
Cited by
Huygen, L., Thys, P. M., Wollenberg, A., Gutermuth, J., & Krohn, I. K. (2024) · Annals of Dermatology · doi:10.5021/ad.23.052 · Cited by 23
Metadata
- Authors
- Plessis, J. D., Stefaniak, A., Eloff, F., John, S., Agner, T., Chou, T., Nixon, R., Steiner, M., Franken, A., Kudla, I., & Holness, L.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2013-01-19
- Volume
- 19
- Issue
- 3
- Pages
- 265-278
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2014054988
- Cited by
- 231
- References
- 88
- FWCI
- 12.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.