An evaluation of mechanical and biophysical skin parameters at different body locations
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Skin is the largest organ in the body, representing an important interface to monitor health and disease. However, there is significant variation in skin properties for different ages, genders and body regions due to the differences in the structure and morphology of the skin tissues. This study aimed to evaluate the use of non‐invasive tools to discriminate a range of mechanical and functional skin parameters from different skin sites. Materials and methods: A cohort of 15 healthy volunteers was recruited following appropriate informed consent. Four well‐established CE‐marked non‐invasive techniques were used to measure four anatomical regions: palm, forearm, sole and lower lumbar L3, using a repeated measures design. Skin parameters included trans‐epidermal water loss (TEWL), pH (acidity), erythema, stratum corneum hydration and stiffness and elasticity using Myoton Pro (skin and muscle probe). Differences between body locations for each parameter and the intra‐rater reliability between days were evaluated by the same operator. Results: The results indicate that parameters differed significantly between skin sites. For the Myoton skin probe, the sole recorded the highest stiffness value of 1006 N/m (SD ± 179), while the lower lumbar recorded the least value of 484 N/m (SD ± 160). The muscle indenter Myoton probe revealed the palm's highest value of 754 N/m (± 108), and the lower lumbar recorded the least value of 208 N/m (SD ± 44). TEWL values were lowest on the forearm, averaging 11 g/m2/h, and highest on the palm, averaging 41 g/m2/h. Similar skin hydration levels were recorded in three of the four sites, with the main difference being observed in the sole averaging 13 arbitrary units. Erythema values were characterised by a high degree of inter‐subject variation, and no significant differences between sites or sides were observed. The Myoton Pro Skin showed excellent reliability (intra‐class correlation coefficients > 0.70) for all sites with exception of one site right lower back; the Myoton pro muscle probes showed good to poor reliability (0.90–017), the corneometer showed excellent reliability (>0.75) among all the sites tested, and the TEWL showed Good to poor reliability (0.74–0.4) among sites. Conclusion: The study revealed that using non‐invasive methods, the biophysical properties of skin can be mapped, and significant differences in the mechanical and functional properties of skin were observed. These parameters were reliably recorded between days, providing a basis for their use in assessing and monitoring changes in the skin during health and disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is widely used, in research only, to monitor the biomechanical behavior of superficial soft tissues (Feng et al., 2018; John et al., 2023).”
From Multimodal assessment of the skin biomechanical properties during wound healing and hyaluronic acid response (2026) · cites this paper as John et al., 2023
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Pinnagoda, J., Tupkek, R. A., Agner, T., & Serup, J. (1990) · Contact Dermatitis · doi:10.1111/j.1600-0536.1990.tb01553.x · Cited by 1,092
A numerical‐experimental method to characterize the non‐linear mechanical behaviour of human skin
Hendriks, F. M., Brokken, D., Van Eemeren, J. T. W. M., Oomens, C. W. J., Baaijens, F. P. T., & Horsten, J. B. A. M. (2003) · Skin Research and Technology · doi:10.1034/j.1600-0846.2003.00019.x · Cited by 347
Research works printed but not linked: 36
- 10.1016/j.jmbbm.2012.05.014 · DOI
- 10.1007/s11249-011-9854-y · DOI · Paper page
- 10.1186/s12938-018-0470-z · DOI
- 10.12968/jowc.2013.22.8.434 · DOI
- 10.1111/j.1600-0846.1999.tb00126.x · doi:10.1111/j.1600-0846.1999.tb00126.x
- 10.1111/j.1365-2133.2008.08703.x · DOI · Paper page
- 10.1111/srt.12833 · DOI
- 10.1111/srt.12109 · DOI · Paper page
- 10.1007/s00403-012-1313-6 · DOI · Paper page
- 10.1111/exd.13826 · DOI
- 10.1034/j.1600-0846.2000.006004214.x · DOI · Paper page
- 10.1007/BF00591373 · DOI · Paper page
- 10.1159/000247752 · DOI · Paper page
- 10.1016/0007-1226(91)90199-T · DOI
- 10.1016/S0268-0033(03)00042-1 · DOI · Paper page
- 10.1111/srt.12946 · DOI
- 10.1111/srt.12956 · DOI
- 10.1111/j.1600-0846.2011.00573.x · DOI
- 10.3390/s22072565 · DOI
- 10.1016/j.jshs.2015.12.001 · DOI
- 10.1123/jsr.2010-0051 · DOI
- Fleiss JL, 2011, Design and analysis of clinical experiments
- 10.1007/s10103-020-03204-x · DOI
- 10.1054/foot.1999.0568 · DOI
- 10.1111/srt.12646 · DOI
- 10.1208/s12248-012-9400-3 · DOI
- 10.1100/2012/386936 · DOI · Paper page
- 10.1111/ics.12068 · DOI · Paper page
- 10.1034/j.1600-0846.2001.70206.x · DOI · Paper page
- 10.1111/j.1600-0536.2007.01138.x · DOI · Paper page
- 10.1001/archderm.1991.04520010052006 · DOI · Paper page
- 10.1159/000211433 · doi:10.1159/000211433
- 10.1016/j.burns.2012.07.026 · DOI
- 10.1111/srt.12692 · DOI
- 10.1111/srt.12256 · DOI
- 10.3109/9781841847641.002 · doi:10.3109/9781841847641.002
Cited by
Bouffandeau, A., Poisbleau, D., Ouidja, M. O. I., Karasinski, P., Papy, D., Flouzat-Lachaniette, C.-H., Bosc, R., Hersant, B., Meningaud, J.-P., & Haiat, G. (2026) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2026.107451 · Cited by 2
Bouffandeau, A., Poisbleau, D., Ouidja, M. O. I., Karasinski, P., Papy, D., Flouzat-Lachaniette, C.-H., Bosc, R., Hersant, B., Meningaud, J.-P., & Haiat, G. (2026) · arXiv · doi:10.48550/arxiv.2611.20949 · Cited by 2
Metadata
- Authors
- John, A. J. U. K., Galdo, F. D., Gush, R., & Worsley, P. R.
- Affiliations
- School of Health Sciences University of Southampton Southampton UK
- Raynaud's and Scleroderma Programme, NIHR Biomedical Research Centre Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds Leeds UK
- Moor Instruments Axminster UK
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2023-02
- Volume
- 29
- Issue
- 2
- ISSN
- 0909-752X
- 1600-0846
- Cited by
- 34
- References
- 3
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An evaluation of mechanical and biophysical skin parameters at different body locations. https://app.cochat.ai/papers/10.1111/srt.13292
- The paper
- John, A. J. U. K., Galdo, F. D., Gush, R., & Worsley, P. R. (2023). An evaluation of mechanical and biophysical skin parameters at different body locations. Skin Research and Technology. https://doi.org/10.1111/srt.13292
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.