A numerical‐experimental method to characterize the non‐linear mechanical behaviour of human skin
Abstract
Background/aims: Human skin is a complex tissue consisting of several distinct layers. Each layer consists of various components with a specific structure. To gain a better insight into the overall mechanical behaviour of the skin, we wish to study the mechanical properties of the different layers. A numerical‐experimental method was developed to characterize the non‐linear mechanical behaviour of human dermis. Methods: Suction measurements at varying pressures were performed on the volar forearm skin of 10 subjects aged 19–24 years old. Deformation of dermis and fat during suction was measured using ultrasound. The experiment was simulated by a finite element model exhibiting extended Mooney material behaviour to account for the non‐linear stress–strain relationship. An identification method is used to compare the experimental and numerical results to identify the parameters of the material model. Results: C 10, dermis was found to be 9.4 ± 3.6 kPa and C11, dermis to be 82 ± 60 kPa. A first rough estimate of C10, fat was 0.02 kPa. Conclusions: The resulting finite element model demonstrated its ability to describe the response of the skin to suction at various pressures. In the future, this method can be used to characterize the mechanical behaviour of different skin layers using various aperture sizes and to characterize the skin behaviour under various loading conditions.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The moduli of dermis and subcutaneous tissue range from 56-260 kPa and 0.12-23 kPa, respectively.
“the modulii of the dermis and subcutaneous tissue range from 56–260 kPa and 0.12–23 kPa, respectively,165–168”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [165]
Cites
Zienkiewicz, O. C. (1989) · Cited by 14,795 · see citing works
The finite element method. Linear static and dynamic finite element analysis
Zimmermann, T. (1987) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(87)90013-2 · Cited by 5,120 · see citing works
The Finite Element Method: Linear Static and Dynamic Finite Element Analysis
Hughes, T. J. R. (1987) · Cited by 4,851 · see citing works
Optimization Toolbox User's Guide
Coleman, T. F., Branch, M. A., & Grace, A. (1998) · Cited by 843 · see citing works
Mechanical properties and Young's modulus of human skin in vivo
Agache, P. G., Monneur, C., Lévêque, J., & de Rigal, J. (1980) · Archives of Dermatological Research · doi:10.1007/bf00406415 · Cited by 742 · see citing works
Handbook of Non-Invasive Methods and the Skin
Serup, J. V., Jemec, G. B. E., & Grove, G. L. (2006) · CRC Press eBooks · doi:10.3109/9781420003307 · Cited by 461 · see citing works
Handbook of non-invasive methods and the skin
Guy, R. H. (1996) · Journal of Controlled Release · doi:10.1016/0168-3659(96)01365-x · Cited by 414 · see citing works
In vivo model of the mechanical properties of the human skin under suction
Diridollou, S., Patat, F., Gens, F., Vaillant, L., Black, D., Lagarde, J., Gall, Y., & Berson, M. (2000) · Skin Research and Technology · doi:10.1034/j.1600-0846.2000.006004214.x · Cited by 350 · see citing works
Mechanical characteristics of skin and underlying tissues in vivo
Bader, D. L., & Bowker, P. (1983) · Biomaterials · doi:10.1016/0142-9612(83)90033-9 · Cited by 204 · see citing works
An In Vivo Method for Measuring the Mechanical Properties of the Skin Using Ultrasound
Diridollou, S., Berson, M., Vabre, V., Black, D., Karlsson, G., Conte-Auriol, F., Grégoire, J., Yvon, C., Vaillant, L., Gall, Y., et al. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00237-8 · Cited by 145 · see citing works
EEMCO Guidance to the in vivo Assessment of Tensile Functional Properties of the Skin
Rodrigues, L. M. (2001) · Skin Pharmacology and Physiology · doi:10.1159/000056334 · Cited by 145 · see citing works
Influence of the Test Area on the Mechanical Properties of Skin
Pierard, G., Nikkels‐Tassoudji, N., & Piérard-Franchimont, C. (2009) · Dermatology · doi:10.1159/000246472 · Cited by 100 · see citing works
Characterisation of Anisotropic and Non-linear Behaviour of Human SkinIn Vivo
Meijer, R., Douven, L. F. A., & Oomens, C. W. J. (1999) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255849908907975 · Cited by 68 · see citing works
Self-citationMaterial Identification Using Mixed Numerical Experimental Methods
Sol, H., & Oomens, C. W. J. (1997) · Springer eBooks · doi:10.1007/978-94-009-1471-1 · Cited by 61 · see citing works
Self-citationA numerical-experimental method for a mechanical characterization of biological materials
Oomens, C. W. J., van Ratingen, M. R., Janssen, J. D., et al. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90024-9 · Cited by 60 · see citing works
Self-citationThe mechanical properties of human skin in vivo
Manschot, J. F. M. (1985) · Radboud Repository (Radboud University) · Cited by 25 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725 · see citing works
Dagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., et al. (2015) · Nature Materials · doi:10.1038/nmat4289 · Cited by 513 · see citing works
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500318 · Cited by 102 · see citing works
- Authors
- Hendriks, F. M., Brokken, D., Van Eemeren, J. T. W. M., Oomens, C. W. J., Baaijens, F. P. T., & Horsten, J. B. A. M.
- Affiliations
- Eindhoven University of Technology (NL)
- Philips (Netherlands) (NL)
- Corresponding author
- Hendriks, F. M.
- ORCID
- Oomens, C. W. J.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2003-07-25
- Volume
- 9
- Issue
- 3
- Pages
- 274-283
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2075285530
- Cited by
- 347
- References
- 16
- Citations by year
- 2026: 7 · 2025: 15 · 2024: 13 · 2023: 17 · 2022: 13 · 2021: 15 · 2020: 19 · 2019: 18 · 2018: 20 · 2017: 20 · 2016: 24 · 2015: 21 · 2014: 16 · 2013: 21 · 2012: 20
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Skin Research and Technology (publishedVersion)
- PubMed (publishedVersion)
- TU/e Research Portal (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
- Keywords
- dermis, suction measurement, finite element model, material parameter identification, skin layers, subcutaneous adipose tissue
- MeSH terms
- Adipose Tissue, Adult, Computer Simulation, Dermatology, Equipment Design, Forearm, Humans, Male, Models, Biological, Pressure, Skin Physiological Phenomena, Suction, Ultrasonography, Nonlinear Dynamics, Finite Element Analysis, Dermis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review