Hemoglobin assessment: precision and practicability evaluated in the Netherlands—the HAPPEN study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Most donors do not like the invasive hemoglobin (Hb) measurement in fingerstick capillary samples. Alternative noninvasive devices have recently become available. In this study we assessed the precision and practicability of noninvasive devices and compared them with measurements in capillary and venous samples. STUDY DESIGN AND METHODS: A total of 2589 blood donors were included in the study. Hb levels were measured with the noninvasive devices NBM 200 or Haemospect and compared with values obtained with the invasive devices HemoCue 201 and HemoCue 301 and with venous values. Precision was evaluated in terms of sensitivity and specificity for detection of Hb levels below the cutoff level for donation, taking venous values as “reference values.” RESULTS: Hb levels measured with both invasive and noninvasive devices differed significantly from venous measurements. Measurements with invasive devices correlated stronger with venous values and were more precise. Sensitivity ranged from 30.1% (HemoCue 201) to 3.5% (Haemospect) in men and from 36.6% (HemoCue 201) to 10.8% (Haemospect) in women. Specificity ranged from 99.8% (HemoCue 201) to 95.5% (Haemospect) in men and from 98.9% (HemoCue 201) to 94.6% (NBM 200) in women. Most donors preferred the noninvasive measurement. CONCLUSION: Measurements with invasive devices showed stronger correlation and better agreement with venous values than noninvasive devices. Sensitivity was low for all measurement devices, particularly the noninvasive ones. In terms of precision invasive measurement would be preferred for donor screening, although a majority of donors preferred the noninvasive measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, capillary [Hb] can be marginally higher than that in venous blood.42–45”
From Hemoglobin concentration, total hemoglobin mass and plasma volume in patients: implications for anemia (2017) · cites this paper as [45]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
The consequences of temporary deferral on future whole blood donation
Custer, B., Chinn, A., Hirschler, N. V., Busch, M. P., & Murphy, E. L. (2007) · Transfusion · doi:10.1111/j.1537-2995.2007.01292.x · Cited by 185 · cited 1×
“Donor deferrals result in lower donor return rates.(4-6) Thus, false-positive results should be kept to a minimum for an adequate donor pool.”
Background
Research works printed but not linked: 18
- The Commission of the European Communities. European Commission Directive 2004/33/EC;2004. · doi:10.1049/ic:20040177
- 10.1111/j.1537-2995.2011.03183.x · DOI · Paper page
- 10.1111/vox.12006 · DOI · Paper page
- 10.1046/j.1537-2995.1998.38298193102.x · DOI
- 10.1111/j.1537-2995.2008.01903.x · DOI
- 10.1111/j.1537-2995.2012.03784.x · DOI
- 10.1111/vox.12033 · DOI
- 10.3343/alm.2013.33.4.261 · doi:10.3343/alm.2013.33.4.261
- 10.1111/trf.12819 · doi:10.1111/trf.12819
- Crowley C, 2012, Validity and correspondence of non‐invasively determined hemoglobin concentrations by two trans‐cutaneous digital measuring devices, Asia Pac J Clin Nutr, 21, 191
- 10.1016/j.transci.2004.11.004 · DOI
- 10.1016/j.transci.2010.07.010 · doi:10.1016/j.transci.2010.07.010
- 10.1016/j.transci.2007.01.010 · DOI
- 10.1111/j.1423-0410.2009.01285.x · DOI · Paper page
- 10.4065/80.5.611 · DOI
- 10.3109/00365513.2011.602422 · DOI · Paper page
- 10.1111/j.1537-2995.2007.01207.x · doi:10.1111/j.1537-2995.2007.01207.x
- Skikne B, 1984, Iron and blood donation, Clin Haematol, 13, 271, 10.1016/S0308-2261(18)30044-4 · doi:10.1016/s0308-2261(18)30044-4
Cited by
Otto, J. M., Plumb, J. O. M., Clissold, E., Kumar, S. B., Wakeham, D. J., Schmidt, W., Grocott, M. P. W., Richards, T., & Montgomery, H. E. (2017) · Haematologica · doi:10.3324/haematol.2017.169680 · Cited by 93
Metadata
- Authors
- Baart, A. M., de Kort, W. L. A. M., van den Hurk, K., & Pasker‐de Jong, P. C. M.
- Affiliations
- Department of Donor Studies Sanquin Research Amsterdam the Netherlands.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2016-03-09
- Volume
- 56
- Issue
- 8
- Pages
- 1984-1993
- ISSN
- 0041-1132
- 1537-2995
- Cited by
- 32
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.