CoChat

Hemoglobin assessment: precision and practicability evaluated in the Netherlands—the HAPPEN study

Baart, A. Mireille, de Kort, Wim L.A.M., van den Hurk, Katja, Pasker‐de Jong, Pieternel C.M. · 2016 · Transfusion
Cited by 32

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Most donors do not like the invasive hemoglobin (Hb) measurement in fingerstick capillary samples. Alternative noninvasive devices have recently become available. In this study we assessed the precision and practicability of noninvasive devices and compared them with measurements in capillary and venous samples. STUDY DESIGN AND METHODS: A total of 2589 blood donors were included in the study. Hb levels were measured with the noninvasive devices NBM 200 or Haemospect and compared with values obtained with the invasive devices HemoCue 201 and HemoCue 301 and with venous values. Precision was evaluated in terms of sensitivity and specificity for detection of Hb levels below the cutoff level for donation, taking venous values as “reference values.” RESULTS: Hb levels measured with both invasive and noninvasive devices differed significantly from venous measurements. Measurements with invasive devices correlated stronger with venous values and were more precise. Sensitivity ranged from 30.1% (HemoCue 201) to 3.5% (Haemospect) in men and from 36.6% (HemoCue 201) to 10.8% (Haemospect) in women. Specificity ranged from 99.8% (HemoCue 201) to 95.5% (Haemospect) in men and from 98.9% (HemoCue 201) to 94.6% (NBM 200) in women. Most donors preferred the noninvasive measurement. CONCLUSION: Measurements with invasive devices showed stronger correlation and better agreement with venous values than noninvasive devices. Sensitivity was low for all measurement devices, particularly the noninvasive ones. In terms of precision invasive measurement would be preferred for donor screening, although a majority of donors preferred the noninvasive measurement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/trf.13546

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 18

  1. The Commission of the European Communities. European Commission Directive 2004/33/EC;2004. · doi:10.1049/ic:20040177
  2. 10.1111/j.1537-2995.2011.03183.x · DOI · Paper page
  3. 10.1111/vox.12006 · DOI · Paper page
  4. 10.1046/j.1537-2995.1998.38298193102.x · DOI
  5. 10.1111/j.1537-2995.2008.01903.x · DOI
  6. 10.1111/j.1537-2995.2012.03784.x · DOI
  7. 10.1111/vox.12033 · DOI
  8. 10.3343/alm.2013.33.4.261 · doi:10.3343/alm.2013.33.4.261
  9. 10.1111/trf.12819 · doi:10.1111/trf.12819
  10. Crowley C, 2012, Validity and correspondence of non‐invasively determined hemoglobin concentrations by two trans‐cutaneous digital measuring devices, Asia Pac J Clin Nutr, 21, 191
  11. 10.1016/j.transci.2004.11.004 · DOI
  12. 10.1016/j.transci.2010.07.010 · doi:10.1016/j.transci.2010.07.010
  13. 10.1016/j.transci.2007.01.010 · DOI
  14. 10.1111/j.1423-0410.2009.01285.x · DOI · Paper page
  15. 10.4065/80.5.611 · DOI
  16. 10.3109/00365513.2011.602422 · DOI · Paper page
  17. 10.1111/j.1537-2995.2007.01207.x · doi:10.1111/j.1537-2995.2007.01207.x
  18. Skikne B, 1984, Iron and blood donation, Clin Haematol, 13, 271, 10.1016/S0308-2261(18)30044-4 · doi:10.1016/s0308-2261(18)30044-4

Cited by

See all 32

Metadata

Authors
Baart, A. M., de Kort, W. L. A. M., van den Hurk, K., & Pasker‐de Jong, P. C. M.
Affiliations
Department of Donor Studies Sanquin Research Amsterdam the Netherlands.
Venue
Transfusion
Publisher
Wiley
Published
2016-03-09
Volume
56
Issue
8
Pages
1984-1993
ISSN
  • 0041-1132
  • 1537-2995
Cited by
32
References
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.