SIMULTANEOUS MEASUREMENT OF UTERINE AND UMBILICAL BLOOD FLOWS AND OXYGEN UPTAKES
The DOI matches its Crossref record.
Abstract
A method is described for the simultaneous estimation of uterine and umbilical blood flows and oxygen uptakes. A test stubstance, antipyrine, was infused at constant rate in the fetal circutlation. About 50 min. after starting the infusion a steady state was attained in which the rate of transplacental diffusion of the test substance was equal, blut for small corrections, to the rate of infusion. During the steady state, blood samples were collected from uterine and umbilical arteries and veins and analyzed for antipyrine and oxygen. Flows and oxygen uptakes were calculated according to Fick's principle. Thie results of sixteen experiments on sheep and goats sh1ow that: (1) transplacental diffusion of antipyrine is mainly flow‐limited, (2) the placenta simulates a concturrent system of exchange, and (3) the oxygen uptakes of the fetus and the utero‐placental mass were, in many cases, of similar magnitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood flow measurements with radionuclide-labeled particles
Heymann, M. A., Payne, B. D., Hoffman, J. I. E., & Rudolph, A. M. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(77)80005-4 · Cited by 2,036
RUDOLPH, A. M., & HEYMANN, M. A. (1967) · Circulation Research · doi:10.1161/01.res.21.2.163 · Cited by 1,316
Circulatory Changes during Growth in the Fetal Lamb
RUDOLPH, A. M., & HEYMANN, M. A. (1970) · Circulation Research · doi:10.1161/01.res.26.3.289 · Cited by 487
Distribution of the circulation in the normal and asphyxiated fetal primate
Behrman, R. E., Lees, M. H., Peterson, E. N., de Lannoy, C. W., & Seeds, A. E. (1970) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(70)90341-8 · Cited by 357
Thorn, S. R., Brown, L. D., Rozance, P. J., Hay, W. W., & Friedman, J. E. (2013) · Diabetes · doi:10.2337/db11-1727 · Cited by 89
“Umbilical plasma and blood flow was determined by steadystate diffusion ((3)H2O) (28,30).”
MethodWallace, J. M., Bourke, D. A., Aitken, R. P., Milne, J. S., & Hay, W. W. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.023333 · Cited by 86
Developmental regulation of glucogenesis in the sheep fetus during late gestation
Fowden, A. L., Mundy, L., & the late Silver, M. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.937bp.x · Cited by 85
Carver, T. D., & Hay, W. W. (1995) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1995.269.2.e299 · Cited by 43
Metadata
- Authors
- Meschia, G., Cotter, J. R., Makowski, E. L., & Barron, D. H.
- Venue
- Quarterly Journal of Experimental Physiology and Cognate Medical Sciences
- Publisher
- Wiley
- Published
- 1967-01-22
- Volume
- 52
- Issue
- 1
- Pages
- 1-18
- ISSN
- 0033-5541 (ISSN-L)
- OpenAlex
- W1966609305
- Cited by
- 193
- References
- 0
- FWCI
- 40.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.