Abstract
Carotid bodies are the sensory organs for detecting systemic hypoxia and the ensuing reflexes prevent the development of tissue/cellular hypoxia. Although every mammalian cell responds to hypoxia, O 2 sensing by the carotid body is unique in that it responds instantaneously (within seconds) to even a modest drop in arterial PO2. Sensing hypoxia in the carotid body requires an initial transduction step involving O 2 sensor(s) and transmitter(s) for subsequent activation of the afferent nerve ending. This brief review focuses on: (a) whether the transduction involves ‘single’ or ‘multiple’ O 2 sensors; (b) the identity of the excitatory transmitter(s) responsible for afferent nerve activation by hypoxia; and (c) whether inhibitory transmitters have any functional role. The currently proposed O 2 sensors include various haem‐containing proteins, and a variety of O 2‐sensitive K+ channels. It is proposed that the transduction involves an ensemble of, and interactions between, haem‐containing proteins and O 2‐sensitive K+‐channel proteins functioning as a ‘chemosome’; the former for conferring sensitivity to wide range of PO2 values and the latter for the rapidity of the response. Hypoxia releases both excitatory and inhibitory transmitters from the carotid body. ATP is emerging as an important excitatory transmitter for afferent nerve activation by hypoxia. Whereas the inhibitory messengers act in concert with excitatory transmitters like a ‘push–pull’ mechanism to prevent over excitation, conferring the ‘slowly adapting’ nature of the afferent nerve activation during prolonged hypoxia. Further studies are needed to test the interactions between putative O 2 sensors and excitatory and inhibitory transmitters in the carotid body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
HIF-1: mediator of physiological and pathophysiological responses to hypoxia
Semenza, G. L. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.88.4.1474 · Cited by 1,822 · cited 1×
“Examples of cellular responses to hypoxia include transcription factor activation and alterations in second messengers, (Semenza, 2000).”
Background
Cited by
Physiology and Pathophysiology of Purinergic Neurotransmission
Burnstock, G. (2007) · Physiological Reviews · doi:10.1152/physrev.00043.2006 · Cited by 1,585
Peripheral Chemoreceptors: Function and Plasticity of the Carotid Body
Kumar, P., & Prabhakar, N. R. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100069 · Cited by 530
Self-citationThe Ventilatory Response to Hypoxia in Mammals: Mechanisms, Measurement, and Analysis
Teppema, L. J., & Dahan, A. (2010) · Physiological Reviews · doi:10.1152/physrev.00012.2009 · Cited by 381
Mitochondria and cellular oxygen sensing in the HIF pathway
Taylor, C. T. (2008) · Biochemical Journal · doi:10.1042/bj20071249 · Cited by 298
Hypoxia Tolerance in Mammals and Birds: From the Wilderness to the Clinic
Ramirez, J.-M., Folkow, L. P., & Blix, A. S. (2007) · Annual Review of Physiology · doi:10.1146/annurev.physiol.69.031905.163111 · Cited by 279
The Effect of Hypoxia on Mesenchymal Stem Cell Biology
Ejtehadifar, M., Shamsasenjan, K., Movassaghpour, A., Akbarzadehlaleh, P., Dehdilani, N., Abbasi, P., Molaeipour, Z., & Saleh, M. (2015) · Advanced Pharmaceutical Bulletin · doi:10.15171/apb.2015.021 · Cited by 235
Involvement of oxygen-sensing pathways in physiologic and pathologic erythropoiesis
Semenza, G. L. (2009) · Blood · doi:10.1182/blood-2009-05-189985 · Cited by 226
Neurotransmitter and neuromodulatory mechanisms at peripheral arterial chemoreceptors
Nurse, C. A. (2010) · Experimental Physiology · doi:10.1113/expphysiol.2009.049312 · Cited by 196
“A growing number of chemical mediators appear to influence CB function, mainly by acting as either presynaptic or postsynaptic neuromodulators (Nurse, 2005; Prabhakar, 2006).”
BackgroundInfluentialResponses of terrestrial insects to hypoxia or hyperoxia
Harrison, J., Frazier, M. R., Henry, J. R., Kaiser, A., Klok, C. J., & Rascón, B. (2006) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2006.02.008 · Cited by 183
Cooper, C. E., & Giulivi, C. (2007) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00310.2006 · Cited by 176
“Multiple transmitters with differing O2 affinities have been proposed to explain the ability of the carotid body to detect O2 in the range from 80 mmHg to 20 mmHg (64).”
BackgroundHydrogen sulfide and oxygen sensing in the cardiovascular system
Olson, K. R., & Whitfield, N. L. (2010) · Antioxidants & Redox Signaling · doi:10.1089/ars.2009.2921 · Cited by 136
K+ channels in O2 sensing and postnatal development of carotid body glomus cell response to hypoxia
Kim, D. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2012.07.005 · Cited by 24
Metadata
- Authors
- Prabhakar, N. R.
- Venue
- Experimental Physiology
- Publisher
- Wiley
- Published
- 2005-12-20
- Volume
- 91
- Issue
- 1
- Pages
- 17-23
- ISSN
- 0958-0670 (ISSN-L)
- 1469-445X
- OpenAlex
- W2156639415
- Cited by
- 156
- References
- 1
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.