Carbon monoxide uptake kinetics of arterial, venous and capillary blood during CO rebreathing
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The uptake and distribution of CO throughout the circulatory system during two different methods of CO rebreathing (2 min ‘Schmidt’ and 40 min ‘Burge’ methods) were determined in nine healthy volunteers. Specifically, the impact of (i) differences in circulatory mixing time (tmix), (ii) CO diffusion to myoglobin (Mb) and (iii) CO wash‐out was assessed on calculated haemoglobin mass (Hb mass). Arterial (a), muscle venous (vm) and capillary samples (c) were obtained simultaneously at 0, 1, 2, 3.5, 5, 7.5, 10, 12.5, 15, 20, 30 and 40 min for determination of carboxyhaemoglobin (HbCO). Carbon monoxide wash‐out was measured from expired air following rebreathing. The rate of CO diffusion to Mb was calculated using the change in HbCO after tmix, and the rate of CO wash‐out. In both methods, HbCO a and HbCO c followed a near‐identical time course, peaking within the first 2 min and decreasing thereafter. The HbCO vm increased slowly and was significantly lower at 1, 2 and 3.5 min in both methods (P < 0.01). The HbCO a peaked significantly higher in the Schmidt method (P= 0.03). Circulatory mixing had occurred by 10 min in most but not all subjects. The rate of CO wash‐out was 0.25 ± 0.13 ml min−1 in the Schmidt and 0.25 ± 0.16 ml min−1 in the Burge method. The rate of CO diffusion to Mb was 0.22 ± 0.11 and 0.16 ± 0.13 ml min−1 (P= 0.63) in Schmidt and Burge methods, respectively. Inhalation of a CO bolus during the Schmidt method results in faster HbCO a uptake but does not greatly shorten tmix or influence rates of CO wash‐out and flux to Mb. The calculated Hb mass depends substantially on the plateau level of HbCO; therefore, it is paramount to ensure HbCO is mixed completely prior to blood sampling, as well as accounting for potential within‐subject alterations of CO exhalation and CO flux to Mb.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Differing blood sample methods (capillary and venous) yield identical Δ%COHb (and thus tHb-mass) values.41”
From Hemoglobin concentration, total hemoglobin mass and plasma volume in patients: implications for anemia (2017) · cites this paper as [41]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Determination of hemoglobin mass and blood volume with CO: evaluation and application of a method
Burge, C. M., & Skinner, S. L. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.2.623 · Cited by 215 · cited 10×
“One test involved the 2 min method of Schmidt & Prommer (2005), whilst the other involved the Burge & Skinner (1995) method, with the subject semi-recumbent throughout both tests.”
BackgroundMethodResultInfluentialSelf-citation
Research works printed but not linked: 24
- 10.1152/jappl.1994.76.4.1739 · DOI
- 10.1172/JCI102551 · doi:10.1172/jci102551
- 10.1152/japplphysiol.00217.2003 · DOI
- 10.1152/japplphysiol.00512.2005 · DOI
- 10.1152/japplphysiol.00298.2010 · DOI · Paper page
- 10.1007/s00421-009-1027-4 · DOI
- 10.1152/japplphysiol.00719.2007 · DOI
- 10.1097/JSM.0b013e3181ddcd5b · DOI · Paper page
- 10.1249/01.mss.0000222848.35004.41 · DOI
- 10.1152/japplphysiol.00505.2005 · DOI · Paper page
- 10.1111/j.1365-2044.2004.03598.x · doi:10.1111/j.1365-2044.2004.03598.x
- Grehant M, 1882, Mesures du volume du sang contenu dans l’organisme d’un mammifere vivant, C. R. Acad. Sci. Paris, 94, 1450
- 10.1097/00005768-200005000-00022 · DOI
- 10.1007/s00421-007-0439-2 · DOI
- 10.1249/MSS.0b013e3181820942 · DOI · Paper page
- 10.1249/MSS.0b013e3181b34b57 · DOI · Paper page
- 10.1097/00005768-200002000-00012 · DOI · Paper page
- 10.1007/s00421-005-0050-3 · DOI · Paper page
- 10.1097/JSM.0b013e31815e981e · doi:10.1097/jsm.0b013e31815e981e
- Smith MV, 1994, Effect of regional circulation patterns on observed HbCO levels, J Appl Physiol, 77, 1659, 10.1152/jappl.1994.77.4.1659 · doi:10.1152/jappl.1994.77.4.1659
- 10.1146/annurev.pa.15.040175.002205 · doi:10.1146/annurev.pa.15.040175.002205
- 10.1080/00365519109091106 · DOI · Paper page
- 10.1152/jappl.1987.63.2.820 · doi:10.1152/jappl.1987.63.2.820
- 10.3109/00365516209079721 · doi:10.3109/00365516209079721
Cited by
Hemoglobin mass and intravascular volume kinetics during and after exposure to 3,454-m altitude
Siebenmann, C., Cathomen, A., Hug, M., Keiser, S., Lundby, A. K., Hilty, M. P., Goetze, J. P., Rasmussen, P., & Lundby, C. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01121.2014 · Cited by 128
Otto, J. M., Plumb, J. O. M., Clissold, E., Kumar, S. B., Wakeham, D. J., Schmidt, W., Grocott, M. P. W., Richards, T., & Montgomery, H. E. (2017) · Haematologica · doi:10.3324/haematol.2017.169680 · Cited by 93
“Differing blood sample methods (capillary and venous) yield identical D%COHb (and thus tHb-mass) values.(41) However, capillary [Hb] can be marginally higher than that in venous blood.”
Intravenous iron supplementation in distance runners with low or suboptimal ferritin
GARVICAN, L. A., SAUNDERS, P. U., CARDOSO, T., MACDOUGALL, I. C., LOBIGS, L. M., FAZAKERLEY, R., FALLON, K. E., ANDERSON, B., ANSON, J. M., THOMPSON, K. G., et al. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182a53594 · Cited by 91
Self-citationGovus, A. D., Garvican-Lewis, L. A., Abbiss, C. R., Peeling, P., & Gore, C. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135120 · Cited by 91
Self-citation
Metadata
- Authors
- Garvican, L. A., Burge, C. M., Cox, A. J., Clark, S. A., Martin, D. T., & Gore, C. J.
- Venue
- Experimental Physiology
- Publisher
- Wiley
- Published
- 2010-09-28
- Volume
- 95
- Issue
- 12
- Pages
- 1156-1166
- ISSN
- 0958-0670
- 1469-445X
- Cited by
- 39
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon monoxide uptake kinetics of arterial, venous and capillary blood during CO rebreathing. https://app.cochat.ai/papers/10.1113/expphysiol.2010.054031
- The paper
- Garvican, L. A., Burge, C. M., Cox, A. J., Clark, S. A., Martin, D. T., & Gore, C. J. (2010). Carbon monoxide uptake kinetics of arterial, venous and capillary blood during CO rebreathing. Experimental Physiology. https://doi.org/10.1113/expphysiol.2010.054031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.