Errors of measurement for blood volume parameters: a meta-analysis
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The volume of red blood cells (V RBC ) is used routinely in the diagnostic workup of polycythemia, in assessing the efficacy of erythropoietin administration, and to study factors affecting oxygen transport. However, errors of various methods of measurement of V RBC and related parameters are not well characterized. We meta-analyzed 346 estimates of error of measurement of V RBC for techniques based on Evans blue (V RBC,Evans ), 51 chromium-labeled red blood cells (V RBC,51Cr ), and carbon monoxide (CO) rebreathing (V RBC,CO ), as well as hemoglobin mass with the carbon-monoxide method (M Hb,CO ), in athletes and active and inactive subjects undergoing various experimental and control treatments lasting minutes to months. Subject characteristics and experimental treatments had little effect on error of measurement, but measures with the smallest error showed some increase in error with increasing time between trials. Adjusted to 1 day between trials and expressed as coefficients of variation, mean errors for M Hb,CO (2.2%; 90% confidence interval 1.4–3.5%) and V RBC,51Cr (2.8%; 2.4–3.2%) were much less than those for V RBC,Evans (6.7%; 4.9–9.4%) and V RBC,CO (6.7%; 3.4–14%). Most of the error of V RBC,Evans was due to error in measurement of volume of plasma via Evans blue dye (6.0%; 4.5–7.8%), which is the basis of V RBC,Evans . Most of the error in V RBC,CO was due to estimates from laboratories with a relatively large error in M Hb,CO , the basis of V RBC,CO . V RBC,51Cr and M Hb,CO are the best measures for research on blood-related changes in oxygen transport. With care, V RBC,Evans is suitable for clinical applications of blood-volume measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The study herein utilized the optimized oCOR method, validated against 51Cr radiolabeling methodologies.40”
From Hemoglobin concentration, total hemoglobin mass and plasma volume in patients: implications for anemia (2017) · cites this paper as [40]
In the citing paper
“Finally, the oCOR method is quick and simple, avoids the technical difficulties of working with radiolabeled compounds,40 offers an inconsequential burden for patients, is minimally invasive, and is safe even in patients with serious medical conditions and comorbidities such as stable coronary artery disease.47”
From Hemoglobin concentration, total hemoglobin mass and plasma volume in patients: implications for anemia (2017) · cites this paper as [40]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
Self-citationAn Approximate Distribution of Estimates of Variance Components
Satterthwaite, F. E. (1946) · Biometrics Bulletin · doi:10.2307/3002019 · Cited by 4,373
Sterne, J. A. C. (2001) · BMJ · doi:10.1136/bmj.322.7280.226 · Cited by 1,466
Wenger, R. H. (2002) · The FASEB Journal · doi:10.1096/fj.01-0944rev · Cited by 1,135 · cited 1×
“increased oxygen-regulated gene expression (147) mediated by”
INCREASED VASCULAR PERMEABILITY: A MAJOR CAUSE OF HYPOALBUMINAEMIA IN DISEASE AND INJURY
Fleck, A., Hawker, F., Wallace, P. I., Raines, G., Trotter, J., Ledingham, I. M., & Calman, K. C. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91447-3 · Cited by 898
Cardiac Atrophy After Bed-Rest Deconditioning: A Nonneural Mechanism for Orthostatic Intolerance
Levine, B. D., Zuckerman, J. H., & Pawelczyk, J. A. (1997) · Circulation · doi:10.1161/01.cir.96.2.517 · Cited by 371 · cited 3×
“VBlood and related measures have featured, in studies of relationships between exercise and aging (24), changes in VBlood, VPlasma, and VRBC with bed rest (90, 104, 108) and spaceflight (1), and, among chronic exercisers (136), changes in cardiac function with training-induced hypervolemia (134) and body fluid redistr…”
Response to exercise after blood loss and reinfusion
Ekblom, B., Goldbarg, A. N., & Gullbring, B. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.33.2.175 · Cited by 346 · cited 1×
“VBlood and related measures have featured, in studies of relationships between exercise and aging (24), changes in VBlood, VPlasma, and VRBC with bed rest (90, 104, 108) and spaceflight (1), and, among chronic exercisers (136), changes in cardiac function with training-induced hypervolemia (134) and body fluid redistr…”
Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure
Saunders, P. U., Telford, R. D., Pyne, D. B., Cunningham, R. B., Gore, C. J., Hahn, A. G., & Hawley, J. A. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00725.2003 · Cited by 228
Self-citationDetermination of hemoglobin mass and blood volume with CO: evaluation and application of a method
Burge, C. M., & Skinner, S. L. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.2.623 · Cited by 215 · cited 17×
“The mean measurement error of the Burge and Skinner method of estimating MHb,CO (1.7%; 1.0–2.8”
InfluentialSelf-citationA Simple Approximation for Unbiased Estimation of the Standard Deviation
Gurland, J., & Tripathi, R. C. (1971) · The American Statistician · doi:10.1080/00031305.1971.10477279 · Cited by 117 · cited 1×
“Each estimate of error was inflated by a factor 1 1/(4 df) to correct for small-sample bias (56).”
Research works printed but not linked: 111
- 10.1152/jappl.1996.81.1.98 · DOI · Paper page
- 10.1097/00005768-200205001-01705 · doi:10.1097/00005768-200205001-01705
- 10.1046/j.1365-201X.1998.0318e.x · DOI · Paper page
- 10.1007/s004210050549 · DOI
- 10.1007/s004210050621 · DOI
- 10.1007/s004210050620 · DOI
- 10.1152/ajpheart.1997.273.2.H687 · DOI · Paper page
- 10.1111/j.1748-1716.1989.tb08687.x · doi:10.1111/j.1748-1716.1989.tb08687.x
- 10.1038/227386a0 · doi:10.1038/227386a0
- Brotherhood J , Brozovic B, and Pugh LGC. Haematological status of middle- and long-distance runners. Clin Sci Mol Med 48 : 139–145, 1975. · DOI · Paper page
- 10.1152/japplphysiol.00217.2003 · DOI
- 10.1152/jappl.1998.85.4.1448 · DOI · Paper page
- 10.1152/jappl.1966.21.2.583 · doi:10.1152/jappl.1966.21.2.583
- 10.1111/j.1399-6576.1993.tb03777.x · DOI
- 10.1152/jappl.1975.39.1.135 · DOI
- 10.1172/JCI114322 · DOI · Paper page
- 10.1152/japplphysiol.00790.2002 · DOI · Paper page
- D'Agostini G . Bayesian Reasoning in Data Analysis, A Critical Introduction . River Edge, NJ: World Scientific Publishing, 2003. · doi:10.1142/5262
- Dahms TE and Horvath SM. Rapid, accurate technique for determination of carbon monoxide in blood. Clin Chem 20 : 533–537, 1974. · DOI · Paper page
- 10.1152/jappl.1994.76.5.2059 · DOI · Paper page
- 10.1152/jappl.1969.27.4.514 · doi:10.1152/jappl.1969.27.4.514
- 10.1152/ajpcell.2001.280.6.C1367 · DOI · Paper page
- 10.1177/036354659602406S12 · DOI
- 10.1006/bcmd.1996.0024 · doi:10.1006/bcmd.1996.0024
- 10.3181/00379727-46-12058 · doi:10.3181/00379727-46-12058
- 10.1001/jama.1967.03120200057007 · DOI · Paper page
- 10.1093/ajcp/92.4.465 · DOI
- Friedmann B , Weller E, Mairbaurl H, and Bartsch P. Effects of iron repletion on blood volume and performance capacity in young athletes. Med Sci Sports Exerc 33 : 741–746, 2001. · DOI · Paper page
- 10.1152/japplphysiol.00684.2001 · DOI · Paper page
- 10.1172/JCI100859 · DOI · Paper page
- 10.1152/jappl.1991.71.5.1914 · DOI · Paper page
- 10.1139/h99-006 · DOI · Paper page
- 10.1159/000192905 · DOI
- 10.1007/s00421-003-0823-5 · DOI
- 10.1016/S1440-2440(98)80011-X · DOI
- 10.1055/s-2007-972667 · DOI · Paper page
- 10.1249/01.MSS.0000113738.06267.E5 · DOI · Paper page
- 10.1126/science.112.2902.179 · doi:10.1126/science.112.2902.179
- 10.1152/jappl.1979.47.5.1031 · DOI · Paper page
- 10.1152/ajpregu.1979.236.3.R206 · DOI · Paper page
- Gregersen MI and Rawson RA. Blood volume. Physiol Rev 39 : 511–518, 1959. · doi:10.1152/physrev.1959.39.4.902-s
- 10.1007/s004210050331 · DOI
- 10.1113/jphysiol.1897.sp000689 · doi:10.1113/jphysiol.1897.sp000689
- Haldane J and Smith JL. The mass and oxygen capacity of the blood in man. J Physiol 25 : 331–343, 1899. · doi:10.1113/jphysiol.1900.sp000800
- 10.3109/00365519609090589 · doi:10.3109/00365519609090589
- 10.1152/jappl.1994.76.5.1922 · DOI
- Haurie C , Dale DC, and Mackey MC. Cyclical neutropenia and other periodic hematological disorders: a review of mechanisms and mathematical models. Blood 92 : 2629–2640, 1998.
- Heinicke K , Heinicke I, Schmidt W, and Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. Int J Sports Med 26: 350–355, 2005. · DOI · Paper page
- 10.1007/s00421-002-0732-z · DOI · Paper page
- 10.1055/s-2001-17613 · DOI · Paper page
- 10.1097/00005768-200109000-00023 · DOI · Paper page
- 10.2165/00007256-200131030-00005 · DOI · Paper page
- 10.1172/JCI101533 · doi:10.1172/jci101533
- 10.1111/j.1365-2141.1973.tb01792.x · DOI · Paper page
- 10.1111/j.1365-2257.1987.tb01384.x · DOI
- 10.1152/ajpregu.00613.2002 · DOI · Paper page
- 10.1152/japplphysiol.00482.2003 · DOI · Paper page
- 10.1152/jappl.1971.31.4.593 · doi:10.1152/jappl.1971.31.4.593
- 10.1089/ham.2004.5.399 · doi:10.1089/ham.2004.5.399
- 10.1152/jappl.1996.81.5.1917 · DOI
- 10.1089/15270290260131911 · DOI · Paper page
- 10.1055/s-2007-1024642 · DOI · Paper page
- 10.1152/jappl.1997.83.1.102 · DOI · Paper page
- Levine BD , Zuckerman JH, Zhang R, and Morrow M. Prolonged intensive endurance training improves ventricular performance via the Frank-Starling mechanism (Abstract). Med Sci Sports Exerc 30 : S27, 1998. · doi:10.1097/00005768-199805001-00150
- 10.1046/j.1365-2362.1997.740627.x · doi:10.1046/j.1365-2362.1997.740627.x
- 10.1016/S0034-5687(00)00221-8 · DOI
- Luomanmäki K and Coburn RF. Effects of metabolism and distribution of carbon monoxide on blood and body stores. Am J Physiol 217 : 354–363, 1969. · DOI
- 10.1046/j.1365-201x.1998.00380.x · DOI · Paper page
- Myhre LG , Brown DK, Hall FG, and Dill DB. The use of carbon monoxide and T-1824 for determining blood volume. Clin Chem 14 : 1197–1205, 1968. · doi:10.1093/clinchem/14.12.1197
- Myhre LG , Dill DB, Hall FG, and Brown DK. Blood volume changes during three-week residence at high altitude. Clin Chem 16 : 7–14, 1970. · DOI
- 10.1172/JCI103015 · doi:10.1172/jci103015
- 10.1097/00005768-200105001-01685 · DOI
- 10.1097/00005768-200205001-01810 · doi:10.1097/00005768-200205001-01810
- Pearson TC . Evaluation of diagnostic criteria in polycythemia vera. Semin Hematol 38 : 21–24, 2001. · DOI · Paper page
- 10.1111/j.1365-2141.1995.tb08411.x · DOI · Paper page
- 10.1161/01.CIR.103.14.1851 · DOI · Paper page
- 10.1177/000456320203900601 · DOI
- Petersen PH , Stockl D, Westgard JO, Sandberg S, Linnet K, and Thienpont L. Models for combining random and systematic errors. Assumptions and consequences for different models. Clin Chem Lab Med 39 : 589–595, 2001. · DOI
- 10.1007/s004210050360 · DOI
- Rawson RA . The binding of T-1824 and structurally related diazo dyes by the plasma proteins. Am J Physiol 138 : 708–717, 1943. · DOI · Paper page
- 10.1152/jappl.2001.91.6.2579 · doi:10.1152/jappl.2001.91.6.2579
- 10.1161/01.CIR.9.4.571 · doi:10.1161/01.cir.9.4.571
- 10.1161/01.RES.9.1.60 · doi:10.1161/01.res.9.1.60
- 10.1152/ajpregu.00226.2002 · DOI · Paper page
- Robach P , Brugniaux JV, Schmitt L, Nicolet G, Fouillot JP, Lasne F, Moutereau S, Olsen NV, and Richalet JP. Living High-Training Low: Effect On Red Cell Mass And Aerobic Performance In Elite Middle-Distance Runners (Abstract). Congress of the European College of Sports Sciences Proceedings, 2004, p. 11–12.
- 10.1152/jappl.2000.89.1.29 · DOI
- 10.1007/s00424-002-0894-x · DOI
- 10.1097/00005768-200002000-00012 · DOI · Paper page
- Sawka MN and Coyle EF. Influence of body water and blood volume on thermoregulation and exercise performance in heat. Exerc Sport Sci Rev 27 : 167–218, 1999. · DOI · Paper page
- 10.1001/jama.1987.03390110072029 · DOI
- 10.1249/00005768-199204000-00009 · DOI · Paper page
- 10.1097/00005768-200212000-00012 · DOI · Paper page
- Sear H , Allen TH, and Gregersen MI. Simultaneous measurement in dogs of plasma volume with I 131 human albumin and T-1824 with comparisons of their long term disappearance from the plasma. Am J Physiol 175 : 240–242, 1953. · doi:10.1152/ajplegacy.1953.175.2.240
- 10.1126/science.6823562 · DOI · Paper page
- 10.1007/BF00665960 · DOI · Paper page
- 10.1152/japplphysiol.00188.2003 · DOI
- 10.1097/00005768-199801000-00013 · DOI · Paper page
- 10.1152/jappl.1994.77.4.1691 · DOI · Paper page
- 10.1152/japplphysiol.00040.2002 · DOI · Paper page
- 10.1152/jappl.1966.21.6.1741 · doi:10.1152/jappl.1966.21.6.1741
- Tavassoli M . Anemia of spaceflight. Blood 60 : 1059–1067, 1982. · DOI · Paper page
- 10.2165/00007256-200333030-00005 · DOI
- Veillon C , Patterson KY, Nagey DA, and Tehan AM. Measurement of blood volume with an enriched stable isotope of chromium ( 53 Cr) and isotope dilution by combined gas chromatography-mass spectrometry. Clin Chem 40 : 71–73, 1994. · doi:10.1093/clinchem/40.1.71
- 10.1001/jama.1956.02960450040010 · doi:10.1001/jama.1956.02960450040010
- 10.1152/ajpheart.2001.280.1.H434 · DOI · Paper page
- 10.1249/01.MSS.0000128163.88298.CB · DOI · Paper page
- 10.3109/00365516209079721 · doi:10.3109/00365516209079721
- 10.1097/00005768-200202000-00006 · DOI
- Witkowski S , Karlsen T, Resaland G, Sivieri M, Yates R, Harber M, Ge R, Stray-Gundersen J, and Levine BD. Optimal altitude for “living high-training low” (Abstract). Med Sci Sports Exerc 33 : S292, 2001. · doi:10.1097/00005768-200105001-01642
- 10.1152/jappl.1991.70.3.1129 · DOI · Paper page
- 10.1152/jappl.2000.89.4.1561 · DOI
Cited by
Combining Hypoxic Methods for Peak Performance
Millet, G. P., Roels, B., Schmitt, L., Woorons, X., & Richalet, J. P. (2010) · Sports Medicine · doi:10.2165/11317920-000000000-00000 · Cited by 431
Tyler, C. J., Reeve, T., Hodges, G. J., & Cheung, S. S. (2016) · Sports Medicine · doi:10.1007/s40279-016-0538-5 · Cited by 352
Taylor, N. A. S. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130022 · Cited by 331
Impact of Alterations in Total Hemoglobin Mass on V˙O2max
Schmidt, W., & Prommer, N. (2010) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3181d4957a · Cited by 265
Iron balance and iron supplementation for the female athlete: A practical approach
Pedlar, C. R., Brugnara, C., Bruinvels, G., & Burden, R. (2018) · European Journal of Sport Science · doi:10.1080/17461391.2017.1416178 · Cited by 111
Metadata
- Authors
- Gore, C. J., Hopkins, W. G., & Burge, C. M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2005-11
- Volume
- 99
- Issue
- 5
- Pages
- 1745-1758
- ISSN
- 8750-7587
- 1522-1601
- Cited by
- 124
- References
- 12
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Errors of measurement for blood volume parameters: a meta-analysis. https://app.cochat.ai/papers/10.1152/japplphysiol.00505.2005
- The paper
- Gore, C. J., Hopkins, W. G., & Burge, C. M. (2005). Errors of measurement for blood volume parameters: a meta-analysis. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00505.2005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.